CLEARANCES FOR SINGLE FLUE

1.Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 115 VAC wall receptacle to properly power appliance.

2.When facing the front of the furnace, the minimum clearances from casing to combustible construction are 0” (0 mm) on top, 0” (0 mm) on each side, recommend 4” (102 mm) for servicing and 0” (0 mm) from the floor and 2” (51 mm) to rear wall for servicing and installation.

3.The minimum distance from the center of the vent cap to the nearest outside corner or obstruction is 12” (305 mm).

The bottom of the exhaust vent terminal and the air intake shall be located at least 12” (305 mm) above grade and must be vented outside.

WARNING: The nearest point of the vent cap should be a minimum horizontal distance of six (6) feet (1.83 m) from any pressure regulator. In case of regulator malfunction, the six (6) feet (1.83 m) distance will reduce the chance of gas entering the vent cap.

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor.

HEATER INSTALLATION FOR SINGLE FLUE

Locating Wall Opening

The recommended location for this heater is on an outside wall (the unit can be located on an inside wall but must not exceed 40’(12.19

m)in exhaust vent length). Locate wall studs so that wall vent opening will be located between wall studs. The wall opening required for venting is a 1 7/8” (48 mm) minimum diameter opening.

Refer to Figures 3 to 6 for positioning the heater on wall and for locating gas line connection and vent opening. Heater can sit on the floor.

Page 10

22618-17-0308

Image 10
Contents Empire Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorRequirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsGAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterIntroduction Specifications Installation Instructions General Safety InformationClearances for Direct Vent Heater Installation for Direct VentInstallation on Rugs and Tile Locating Wall OpeningHeater Installation for Single Flue Clearances for Single FlueHeater with Pedestal and Single Flue Adaptor Specifications Heater without pedestalFireplace Insert with Mantel Surround with Slim Top Panel Fireplace Insert with Mantel Surround with Short Top Panel Clearance to Combustibles Freestanding UnitsRough Framing Dimensions Insert Into Masonry FireplaceWall Clearances LOG SET Installation Instructions Log Installation All LogsVent Examples for Single Flue Single Flue Venting with Shroud Installed Venting for Existing Fireplace InstallationSingle Flue Vertical Vent Run Shroud Kit Model# Pvsh Roof Determining Minimum Vent Height AboveSingle Flue Vertical Vent Run With 45 degree elbows Available from Empire Comfort Systems, Inc PVVK-CFA Flex Vent KITDetermining Minimum Vent Height Above the Roof PVVK-SH Horizontal Vent Adaptor KIT Horizontal Examples for Colinear Direct Vent Vertical Examples for Colinear Direct Vent Colinear Direct Vent Pitched Roof Installation Pvca Horizontal Colinear Direct Vent Adaptor Colinear adaptorPvvtc Termination CAP Vent KIT Termination CapFlat Roof or Chimney Application Pvct Colinear Transition Vent KITHorizontal Application Horizontal Venting Direct Vent Installation InstructionsDirect Vent System Building Exterior View Minimum Exterior Grade Dimension Unit Without Pedestal Minimum Exterior Grade Dimension Unit With PedestalPVVK-24H and PVVK-48H Vent KIT StepPVVK-24H and PVVK-48H Vent KIT GAS Connection Installation Instructions GAS Connection Line SupplyOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation GAS Conversion Instructions Conversion Instructions from LP Propane GAS to Natural GASConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Installation Instruction for TMV2 Two Stage Thermostat Model Optional ControllersEconomy Display Mode Wiring Wiring DiagramGeneral Information MaintenanceOver Temperature Cut Out Paint Curing First FiringMain Burner Drawing Cleaning Main Burner Front door removal drawing Glass CleaningGlass Assembly Replacement General Glass InformationResetting the Heater Unit Operating FaultsLOG Placement Main Convection FAN Surround Installation InstructionsHeat Exchanger Pedestal Installation Instructions Optional Pedestal Assembly InstallationParts List Index Part Number DescriptionGAS Line Front Parts View 7368 Warranty Terms Purchase Date Dealer Name/PhoneHOW to Order Repair Parts Service NotesComfort Systems

BP)-1, GN, PV-28SV50-BN, CP, GP)-1 specifications

Empire Comfort Systems is renowned for producing high-quality heating products, and the GP-1, GN, PV-28SV55-CN, CP, BP-1 is no exception. This comprehensive heating solution combines innovative technologies with practical features designed to enhance comfort and efficiency in various environments.

The GP-1 model is a direct vent gas log set that showcases the brand's commitment to producing clean and efficient heating options. One of its standout characteristics is its ability to operate without needing a traditional chimney, making it an excellent choice for homes where a fireplace may not have been previously installed. The direct vent design uses outside air for combustion, ensuring optimal efficiency while minimizing energy loss.

What sets the GN model apart is its impressive output capacity. Engineered for robustness, this gas heater can deliver significant warmth, making it ideal for larger spaces or homes in colder climates. The unit is designed to heat quickly and evenly, providing a comfortable living environment without drastic fluctuations in temperature.

The PV-28SV55-CN brings advanced technology into the fold with its vent-free capabilities. This feature allows for installation flexibility, as it can be positioned in various spaces without requiring venting to the outside. This characteristic not only simplifies installation but also allows users to enjoy the warmth without the hassle of dealing with exterior vents.

The CP and BP-1 models focus on user convenience and safety. Both are equipped with state-of-the-art control systems that allow users to manage their heating options easily. The intuitive controls facilitate temperature adjustments, ensuring users can maintain their preferred heat levels effortlessly. Additionally, safety features such as oxygen depletion sensors (ODS) provide peace of mind by automatically shutting off the unit if unsafe conditions arise.

In terms of design, Empire Comfort Systems has ensured that these models fit seamlessly into any décor. The stylish aesthetic, combined with a variety of finish and style options, allows homeowners to choose a gas fireplace that complements their interior design.

In conclusion, the Empire Comfort Systems GP-1, GN, PV-28SV55-CN, CP, BP-1 represents a harmonious blend of advanced technology, safety features, and elegant design. It is an exemplary choice for anyone seeking to enhance their home's warmth and efficiency while enjoying the beauty and ambiance a gas heating solution can provide. With a focus on comfort, reliability, and aesthetic appeal, these models stand out as top contenders in the market for home heating solutions.