Empire Comfort Systems CP, PV-28SV50-BN, PV-28SV55-CN, GN, GP)-1 Operating Instructions Checklist

Page 35

OPERATING INSTRUCTIONS CHECKLIST

BEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECKLIST

1.Read and understand these instructions before installing or operating this appliance.

2.This appliance is should be installed and repaired by a fully qualified service person who must be familiar with the instal- lation of the Mantis Power-Vent High-Efficiency Fireplace.

3.Installers who are not familiar with the installation of this ap- pliance should contact Empire Comfort Systems, Inc. prior to installing the appliance to avoid creating hazardous operating conditions.

4.Check and inspect the appliance for gas leaks. In the event of gas leaks, cut off the gas supply to the heater immediately and call your gas supplier or installer.

5.Check and verify that all flue venting combustion air intakes and flue outlets are unobstructed.

6.Refer to pages 19 to 21 for Single Flue pipe and pages 30 to 31 for Co-axial Flue installations. Check that correct flue pipe and cap has been fitted in line with the manufacturer’s specifications as illustrated in this manual pages 11 to 31.

7.Do not use alternative Flue or cap on installation other than that specified in this manual - otherwise heater will malfunc- tion and cause hazardous operating conditions and will void the manufacturer’s warranty.

8.Check and verify that flue pipe connection to the appliance when using single 1 1/2” flue pipe installation is correctly installed and secured in line with instruction in this manual, Pages 19 to 21.

9.Prior to operating the appliance, check for dust or debris on the burners. Refer to Page 46, Figure 56.

10.Check and verify that logs are place correctly as per instruc- tions on Page 18 of this manual. If logs are incorrectly po- sitioned, it can create a hazardous situation, and in most in- stances, the heater will not operate correctly.

11.Do not light heater without logs installed, as heater will not operate properly.

12.Check and verify prior to starting the appliance, that all panels are secured in place and that the main door has been locked in position.

13.After verifying and checking all the above points, proceed to lighting instructions. Refer to pages 37 to 38.

22618-17-0308

Page 35

Image 35
Contents Empire Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASVent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsRecommended Gas Pipe Diameter Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyIntroduction Installation Instructions General Safety Information SpecificationsLocating Wall Opening Heater Installation for Direct VentInstallation on Rugs and Tile Clearances for Direct VentClearances for Single Flue Heater Installation for Single FlueHeater with Pedestal and Single Flue Adaptor Heater without pedestal SpecificationsFireplace Insert with Mantel Surround with Slim Top Panel Fireplace Insert with Mantel Surround with Short Top Panel Freestanding Units Clearance to CombustiblesInsert Into Masonry Fireplace Rough Framing DimensionsWall Clearances Log Installation All Logs LOG SET Installation InstructionsVent Examples for Single Flue Single Flue Vertical Vent Run Shroud Kit Model# Pvsh Venting for Existing Fireplace InstallationSingle Flue Venting with Shroud Installed Single Flue Vertical Vent Run With 45 degree elbows Determining Minimum Vent Height AboveRoof Determining Minimum Vent Height Above the Roof PVVK-CFA Flex Vent KITAvailable from Empire Comfort Systems, Inc PVVK-SH Horizontal Vent Adaptor KIT Horizontal Examples for Colinear Direct Vent Vertical Examples for Colinear Direct Vent Colinear Direct Vent Pitched Roof Installation Colinear adaptor Pvca Horizontal Colinear Direct Vent AdaptorTermination Cap Pvvtc Termination CAP Vent KITHorizontal Application Pvct Colinear Transition Vent KITFlat Roof or Chimney Application Direct Vent System Building Exterior View Direct Vent Installation InstructionsHorizontal Venting Minimum Exterior Grade Dimension Unit With Pedestal Minimum Exterior Grade Dimension Unit Without PedestalStep PVVK-24H and PVVK-48H Vent KITPVVK-24H and PVVK-48H Vent KIT GAS Connection Line Supply GAS Connection Installation InstructionsOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation Conversion Instructions from LP Propane GAS to Natural GAS GAS Conversion InstructionsConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Optional Controllers Installation Instruction for TMV2 Two Stage Thermostat ModelEconomy Display Mode Wiring Diagram WiringPaint Curing First Firing MaintenanceOver Temperature Cut Out General InformationGeneral Glass Information Front door removal drawing Glass CleaningGlass Assembly Replacement Main Burner Drawing Cleaning Main BurnerLOG Placement Unit Operating FaultsResetting the Heater Heat Exchanger Surround Installation InstructionsMain Convection FAN Optional Pedestal Assembly Installation Pedestal Installation InstructionsIndex Part Number Description Parts ListGAS Line Front Parts View 7368 Purchase Date Dealer Name/Phone Warranty TermsService Notes HOW to Order Repair PartsComfort Systems

BP)-1, GN, PV-28SV50-BN, CP, GP)-1 specifications

Empire Comfort Systems is renowned for producing high-quality heating products, and the GP-1, GN, PV-28SV55-CN, CP, BP-1 is no exception. This comprehensive heating solution combines innovative technologies with practical features designed to enhance comfort and efficiency in various environments.

The GP-1 model is a direct vent gas log set that showcases the brand's commitment to producing clean and efficient heating options. One of its standout characteristics is its ability to operate without needing a traditional chimney, making it an excellent choice for homes where a fireplace may not have been previously installed. The direct vent design uses outside air for combustion, ensuring optimal efficiency while minimizing energy loss.

What sets the GN model apart is its impressive output capacity. Engineered for robustness, this gas heater can deliver significant warmth, making it ideal for larger spaces or homes in colder climates. The unit is designed to heat quickly and evenly, providing a comfortable living environment without drastic fluctuations in temperature.

The PV-28SV55-CN brings advanced technology into the fold with its vent-free capabilities. This feature allows for installation flexibility, as it can be positioned in various spaces without requiring venting to the outside. This characteristic not only simplifies installation but also allows users to enjoy the warmth without the hassle of dealing with exterior vents.

The CP and BP-1 models focus on user convenience and safety. Both are equipped with state-of-the-art control systems that allow users to manage their heating options easily. The intuitive controls facilitate temperature adjustments, ensuring users can maintain their preferred heat levels effortlessly. Additionally, safety features such as oxygen depletion sensors (ODS) provide peace of mind by automatically shutting off the unit if unsafe conditions arise.

In terms of design, Empire Comfort Systems has ensured that these models fit seamlessly into any décor. The stylish aesthetic, combined with a variety of finish and style options, allows homeowners to choose a gas fireplace that complements their interior design.

In conclusion, the Empire Comfort Systems GP-1, GN, PV-28SV55-CN, CP, BP-1 represents a harmonious blend of advanced technology, safety features, and elegant design. It is an exemplary choice for anyone seeking to enhance their home's warmth and efficiency while enjoying the beauty and ambiance a gas heating solution can provide. With a focus on comfort, reliability, and aesthetic appeal, these models stand out as top contenders in the market for home heating solutions.