Empire Comfort Systems GP)-1, PV-28SV50-BN, GN, BP)-1 Determining Minimum Vent Height Above, Roof

Page 21

VENT EXAMPLES FOR SINGLE FLUE (cont.)

Figure 22

Minimum Exterior Grade Dimension - Single Flue, Horizontal Venting Below Floor

H

2 - 45 DEG. PVC BENDS (SUPPLIED BY INSTALLER)

MANTEL

SURROUND

MODEL #PVE-1

VENT CAP

(SUPPLIED WITH VENT KIT) MODEL #PVVK-SV

FLASHING

ROOF PITCH

12

 

IS X

 

 

X

12

 

 

 

Determining Minimum Vent Height Above

 

 

 

 

 

 

the Roof

 

 

 

 

 

 

 

 

 

ROOF PITCH

H (Min.)

 

 

 

Flat to 6/12

12” (305 mm)

 

 

 

 

 

 

 

 

6/12 to 7/12

15” (381 mm)

 

 

 

Over 7/12 to 8/12

18” (457 mm)

 

 

 

Over 8/12 to 16/12

24” (610 mm)

 

 

 

Over 16/12 to 21/12

36” (914 mm)

PVC PIPE

(SUPPLIED BY INSTALLER)

FLEXIBLE PVC PIPE

WITH 1/2” COUPLING ON EACH END

MODEL #PVVK-CFA

GAS SUPPLY

Figure 23

Single Flue - Vertical Vent Run

with 45 degree elbows

WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are necessary in the interest of safety. These specifications are summarized in Figure 23.

22618-17-0308

Page 21

Image 21
Contents Empire Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASVent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsPressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterIntroduction Installation Instructions General Safety Information SpecificationsInstallation on Rugs and Tile Heater Installation for Direct VentClearances for Direct Vent Locating Wall OpeningClearances for Single Flue Heater Installation for Single FlueHeater with Pedestal and Single Flue Adaptor Heater without pedestal SpecificationsFireplace Insert with Mantel Surround with Slim Top Panel Fireplace Insert with Mantel Surround with Short Top Panel Freestanding Units Clearance to CombustiblesInsert Into Masonry Fireplace Rough Framing DimensionsWall Clearances Log Installation All Logs LOG SET Installation InstructionsVent Examples for Single Flue Venting for Existing Fireplace Installation Single Flue Venting with Shroud InstalledSingle Flue Vertical Vent Run Shroud Kit Model# Pvsh Determining Minimum Vent Height Above RoofSingle Flue Vertical Vent Run With 45 degree elbows PVVK-CFA Flex Vent KIT Available from Empire Comfort Systems, IncDetermining Minimum Vent Height Above the Roof PVVK-SH Horizontal Vent Adaptor KIT Horizontal Examples for Colinear Direct Vent Vertical Examples for Colinear Direct Vent Colinear Direct Vent Pitched Roof Installation Colinear adaptor Pvca Horizontal Colinear Direct Vent AdaptorTermination Cap Pvvtc Termination CAP Vent KITPvct Colinear Transition Vent KIT Flat Roof or Chimney ApplicationHorizontal Application Direct Vent Installation Instructions Horizontal VentingDirect Vent System Building Exterior View Minimum Exterior Grade Dimension Unit With Pedestal Minimum Exterior Grade Dimension Unit Without PedestalStep PVVK-24H and PVVK-48H Vent KITPVVK-24H and PVVK-48H Vent KIT GAS Connection Line Supply GAS Connection Installation InstructionsOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation Conversion Instructions from LP Propane GAS to Natural GAS GAS Conversion InstructionsConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Optional Controllers Installation Instruction for TMV2 Two Stage Thermostat ModelEconomy Display Mode Wiring Diagram WiringOver Temperature Cut Out MaintenanceGeneral Information Paint Curing First FiringGlass Assembly Replacement Front door removal drawing Glass CleaningMain Burner Drawing Cleaning Main Burner General Glass InformationUnit Operating Faults Resetting the HeaterLOG Placement Surround Installation Instructions Main Convection FANHeat Exchanger Optional Pedestal Assembly Installation Pedestal Installation InstructionsIndex Part Number Description Parts ListGAS Line Front Parts View 7368 Purchase Date Dealer Name/Phone Warranty TermsService Notes HOW to Order Repair PartsComfort Systems

BP)-1, GN, PV-28SV50-BN, CP, GP)-1 specifications

Empire Comfort Systems is renowned for producing high-quality heating products, and the GP-1, GN, PV-28SV55-CN, CP, BP-1 is no exception. This comprehensive heating solution combines innovative technologies with practical features designed to enhance comfort and efficiency in various environments.

The GP-1 model is a direct vent gas log set that showcases the brand's commitment to producing clean and efficient heating options. One of its standout characteristics is its ability to operate without needing a traditional chimney, making it an excellent choice for homes where a fireplace may not have been previously installed. The direct vent design uses outside air for combustion, ensuring optimal efficiency while minimizing energy loss.

What sets the GN model apart is its impressive output capacity. Engineered for robustness, this gas heater can deliver significant warmth, making it ideal for larger spaces or homes in colder climates. The unit is designed to heat quickly and evenly, providing a comfortable living environment without drastic fluctuations in temperature.

The PV-28SV55-CN brings advanced technology into the fold with its vent-free capabilities. This feature allows for installation flexibility, as it can be positioned in various spaces without requiring venting to the outside. This characteristic not only simplifies installation but also allows users to enjoy the warmth without the hassle of dealing with exterior vents.

The CP and BP-1 models focus on user convenience and safety. Both are equipped with state-of-the-art control systems that allow users to manage their heating options easily. The intuitive controls facilitate temperature adjustments, ensuring users can maintain their preferred heat levels effortlessly. Additionally, safety features such as oxygen depletion sensors (ODS) provide peace of mind by automatically shutting off the unit if unsafe conditions arise.

In terms of design, Empire Comfort Systems has ensured that these models fit seamlessly into any décor. The stylish aesthetic, combined with a variety of finish and style options, allows homeowners to choose a gas fireplace that complements their interior design.

In conclusion, the Empire Comfort Systems GP-1, GN, PV-28SV55-CN, CP, BP-1 represents a harmonious blend of advanced technology, safety features, and elegant design. It is an exemplary choice for anyone seeking to enhance their home's warmth and efficiency while enjoying the beauty and ambiance a gas heating solution can provide. With a focus on comfort, reliability, and aesthetic appeal, these models stand out as top contenders in the market for home heating solutions.