Empire Comfort Systems CIBV-30-2 installation instructions Optional Blower CIB-2

Page 20

OPTIONAL BLOWER CIB-2

Vented Fireplace Heater CIBV-30

Installing Optional CIB-2 Blower

1.Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance.

2.Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the appliance.

3.Place the large diameter holes in the keyholes over and behind the (4) hex-head screws that were loosened in Step 1. Push inward on the blower assembly to lock the keyholes into position behind the screws. Tighten (4) hex-head screws to secure blower assembly to exterior, bottom of the appliance.

4.Remove wire channel from rear cover by removing (4) hex- head screws. Note: If optional blower is being installed during initial installation of appliance, the wire channel will not be attached to rear cover. (Refer to Installation of Wire Channel Assembly, Page 8)

5.Attach fan control to FLAT, fan control bracket (Part 9A, Page 21) with (2) 6 x 1/4" screws provided in hardware package.

6.Attach fan control with bracket onto the wire channel by using (2) 8 x 1/4" screws provided in hardware package.

7.Route wires from fan control and ON/OFF/REMOTE switch within wire channel.

8.When facing the rear of the appliance, align and insert fan control with bracket into 1 3/8" x 2" opening on the left side of the rear cover.

9.Attach wire channel to rear cover by using (4) hex-head screws removed in Step 4. (Refer to Installation of Wire Channel Assembly, Page 8)

10.Insert AUTO/OFF/ON switch into rectangular notch on valve bracket. Be sure to insert AUTO/OFF/ON switch with letters (words) upright. (See wiring diagram)

11.Attach 1/4" push-on terminal from blue wire on the fan control to the AUTO (top) tab on the switch.

12.Attach 1/4" push-on terminal from black wire to the OFF (middle) tab on the switch.

13.Attach 1/4" push-on terminal from white wire on the fan control to the ON (bottom) tab on the switch.

14.Installation of optional CIB-2 blower is completed.

Fan Control

The fan control is a non-adjustable automatic type. The fan control will require between 5 and 10 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 5 and 10 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING:

Unplugging of blower accessory will not stop the heater from cycling. To shut heater off: Turn temperature dial or thermostat to lowest setting. Turn knob on gas control to "OFF", depressing slightly. Do not force.

Page 20

R-3450

Image 20
Contents Installation Instructions Cast Iron Vented Fireplace HeaterThis is a Heating Appliance Safety Information for Users of LP-GAS LP-GAS Warning OdorQualified Installing Agency Locating and Venting the Fireplace Heater Figures 1, 2Appliance Hardware Package Parts List Page Page Stone Inlay Replacement of Standard Grille Top Installation of Optional Stone InlayParts List Installation of Wire Channel Assembly FigureInstalling a New Main Gas Cock Gas Supply FigureInside Diameter Outside Diameter Never Use an Exposed Flame to Check for LeaksVent Safety Shutoff System Insulated Vent Enclosure FigureHigh Altitudes Piezo Ignitor ButtonAir Shutter Adjustment Cleaning the Log Set and FireboxCIBV-30 ON/OFF/REMOTE Switch Operation of ON/OFF/REMOTE Switch with no AccessoriesElectric 120 volt Operated Remote Control, FREC-1 Installation of Remote Receiver FigureWiring Diagram Figure Manual OperationInstallation of Logs and Figure General Glass InformationMaintenance & Service Instructions Clean Burner and Control CompartmentCleaning Procedure Operating GuidelinesFor Your Safety Read Before Lighting Standing PILOT-TROUBLE Shooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass soots3450 Parts List for CIBV-30 Firebox 3450 Optional Blower CIB-2 Parts List Service Notes

CIBV-30-2 specifications

Empire Comfort Systems has long been a trusted name in the heating industry, providing reliable and efficient heating solutions for homes. One of their standout products is the CIBV-30-2 direct vent gas fireplace, which combines modern technology with aesthetic appeal.

The CIBV-30-2 is designed to deliver warmth and charm to any space while ensuring maximum efficiency. With a compact design, this model is perfect for smaller rooms or areas where space is at a premium. Its direct vent technology allows for the safe exhaust of combustion gases, which enhances indoor air quality. This feature makes the CIBV-30-2 an excellent choice for homeowners looking to enjoy the comfort of a fireplace without the concerns associated with traditional wood-burning options.

One of the key characteristics of the CIBV-30-2 is its capability to provide a steady heat output of up to 30,000 BTUs, ensuring that even the coldest days feel cozy. The fireplace operates on either natural gas or propane, catering to different user preferences and needs. This flexibility makes it an ideal option for various homes and setups. The unit’s efficiency rating is impressive, with a thermal efficiency of over 80%, which means less fuel is consumed while still delivering substantial heat.

Aesthetically, the CIBV-30-2 boasts a stunning view of the flames, thanks to its large glass front. This feature not only enhances the ambiance of the room but also allows easy monitoring of the fire. The fireplace is available with optional decorative rock or log sets, enabling homeowners to customize the look to suit their decor style.

Additionally, the CIBV-30-2 is equipped with advanced controls that allow for precise temperature management. Optional remote control features are available, giving users added convenience to adjust the settings from a distance. Safety is also a priority; the unit includes built-in safety features to prevent over-heating and ensure reliable operation.

In summary, the Empire Comfort Systems CIBV-30-2 direct vent gas fireplace combines efficiency, flexibility, and beauty, making it an excellent choice for anyone looking to enhance their home’s comfort and style. With its modern design, advanced technology, and user-friendly features, this fireplace stands out as a remarkable solution for heating and ambiance in any living space.