Empire Comfort Systems CIBV-30-2 Stone Inlay Replacement of Standard Grille Top, Parts List

Page 8

Stone Inlay Replacement of Standard Grille Top

Whenever the standard grille top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay.

Installation of Optional Stone Inlay

1.Remove left grille, center grille and right grille from casing top.

2.Remove casing top from outer casing.

3.Place the casing top on a non-abrasive surface in order to protect the porcelain finish. The exterior of the casing top should be facing the non-abrasive surface.

4.Attach 11 5/8" x 11 5/8" top shield to the interior of the casing top with (1) 3/8" bolt provided in hardware package.

5.Remove the (2) 1/2" hex-head screws located on the front of the heat exchanger top. The screws are 8 3/4" apart. Do not remove the center hex-head screw. Remove the (2) screw hole, knockouts located on the back of the heat exchanger top. The knockouts are 8 3/4" apart. Position the angled front on the 12" x 19 3/8" heat shield with the front of the appliance. Align the (4) tabs with clearance holes on the 12" x 19 3/8" heat shield with the (4) screw holes on the heat exchanger top. Attach the 12" x 19 3/8" heat shield to the heat exchanger top with (2) 1/2" hex-head screws removed in Step 5 and

(2) 1/2" hex-head screws provided in hardware package.

6.Place the casing top onto the outer casing. The casing top nests into the outer casing.

7.Insert center stone inlay, left stone inlay and right stone inlay into casing top.

8.Installation of stone inlay is completed.

Parts List

 

Part

Part

Quantity

 

 

Description

Number

Supplied

 

 

 

 

 

 

 

11 5/8" x 11 5/8" Top Shield

CI-091

1

 

 

12" x 19 3/8" Heat Shield

CI-092

1

 

 

 

 

 

 

 

3/8" Bolt

R-3646

1

 

 

 

 

 

 

 

1/2" Hex-Head Screw

R-2737

4

 

Installation of Wire Channel Assembly (Figure 10)

The ON/OFF/REMOTE switch with harness is factory installed into the switch box.

After the appliance housing is installed into the cast iron outer casing the wire channel can be installed.

1.Attach switch box on the left side of casing back with (2) 10 x 1/2" provided screws.

2.Route wires from ON/OFF/REMOTE switch within wire channel.

3.Attach wire channel on the left side of the casing back with (4) 10 x 1/2" provided screws.

4.Attach the black and green (wires) female push-ons to the TH/TP and TH (two outside male tabs) terminals on gas valve.

5.Identify vent safety switch wire harness. The first wire is installed into magnet section on gas valve. The second wire is attached to the TH/TP terminal on gas valve. Route opposite end of vent safety switch wire harness within (2) metal clips on exterior of rear cover. Attach (2) 1/4" female push-ons on vent safety switch wire harness onto (2) 1/4" male tabs on vent safety switch which is located on the side of draft diverter.

Figure 10

Venting

1.Flue pipe must be as large as the flue collar on the draft diverter.

2.Maintain an upward slope of at least 1/4 inch (6mm) per foot of horizontal run.

3.Run flue pipe as directly as possible with a minimum of elbows.

4.Flue pipe should extend through the wall of a chimney to be flush with inner wall.

5.Flue pipe must be adequately supported by metal straps.

6.Single wall vent pipe may be attached directly to the draft hood of the fireplace heater when a clearance of 2 1/2 inches (64mm) is maintained between the single wall vent pipe and the combustible wall of the room in which the fireplace heater is located. Use double wall vent pipe for clearances less than 2 1/2 inches (64mm) to combustibles.

7.For flue pipe running through walls and roof, use B-1 [1 inch (25mm) clearance to combustibles] vent pipe.

8.Chimneys should extend at least 2 feet (.6m) above the roof and above any object or nearby building within 10 feet (3m).

9.Open tees should not be used in the flue pipe.

10.Appliance must not be connected to a chimney flue that is servicing a separate solid-fuel burning appliance.

For proper venting, do not attach a 90° elbow directly to draft diverter. If possible, attach 2 feet (.6m) of straight vent pipe before an elbow is used. Use of 45° elbows is recommended.

Uninsulated single-wall metal pipe shall not be used outdoors in cold climates for venting gas utilization equipment.

Ventilation and Combustion Air

Fireplace heaters shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions. In buildings of conventional frame, brick or stone construction without tight storm windows and doors, infiltration is normally adequate to provide for combustion and draft hood dilution.

Where appliances are installed in a confined space within a building, the building being of unusually tight construction, air for combustion and ventilation must be obtained directly from outdoors or from such spaces that freely communicate with the outdoors. Under these conditions, the confined space shall be provided with two permanent openings, one near the top of the enclosure and one near the bottom; each opening shall have a free area of not less than one square inch (6.5cm2) per 1,000 BTU's (.3KW) of total input. The draft hood must be in the same atmospheric pressure zone as the combustion air inlet to the appliance and shall be so located so that the relief opening is accessible for checking vent operation.

Page 8

R-3450

Image 8
Contents Installation Instructions Cast Iron Vented Fireplace HeaterThis is a Heating Appliance Safety Information for Users of LP-GAS LP-GAS Warning OdorQualified Installing Agency Locating and Venting the Fireplace Heater Figures 1, 2Appliance Hardware Package Parts List Page Page Stone Inlay Replacement of Standard Grille Top Installation of Optional Stone InlayParts List Installation of Wire Channel Assembly FigureInstalling a New Main Gas Cock Gas Supply FigureInside Diameter Outside Diameter Never Use an Exposed Flame to Check for LeaksVent Safety Shutoff System Insulated Vent Enclosure FigureHigh Altitudes Piezo Ignitor ButtonAir Shutter Adjustment Cleaning the Log Set and FireboxCIBV-30 ON/OFF/REMOTE Switch Operation of ON/OFF/REMOTE Switch with no AccessoriesElectric 120 volt Operated Remote Control, FREC-1 Installation of Remote Receiver FigureWiring Diagram Figure Manual OperationInstallation of Logs and Figure General Glass InformationMaintenance & Service Instructions Clean Burner and Control CompartmentCleaning Procedure Operating GuidelinesFor Your Safety Read Before Lighting Standing PILOT-TROUBLE Shooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass soots3450 Parts List for CIBV-30 Firebox 3450 Optional Blower CIB-2 Parts List Service Notes

CIBV-30-2 specifications

Empire Comfort Systems has long been a trusted name in the heating industry, providing reliable and efficient heating solutions for homes. One of their standout products is the CIBV-30-2 direct vent gas fireplace, which combines modern technology with aesthetic appeal.

The CIBV-30-2 is designed to deliver warmth and charm to any space while ensuring maximum efficiency. With a compact design, this model is perfect for smaller rooms or areas where space is at a premium. Its direct vent technology allows for the safe exhaust of combustion gases, which enhances indoor air quality. This feature makes the CIBV-30-2 an excellent choice for homeowners looking to enjoy the comfort of a fireplace without the concerns associated with traditional wood-burning options.

One of the key characteristics of the CIBV-30-2 is its capability to provide a steady heat output of up to 30,000 BTUs, ensuring that even the coldest days feel cozy. The fireplace operates on either natural gas or propane, catering to different user preferences and needs. This flexibility makes it an ideal option for various homes and setups. The unit’s efficiency rating is impressive, with a thermal efficiency of over 80%, which means less fuel is consumed while still delivering substantial heat.

Aesthetically, the CIBV-30-2 boasts a stunning view of the flames, thanks to its large glass front. This feature not only enhances the ambiance of the room but also allows easy monitoring of the fire. The fireplace is available with optional decorative rock or log sets, enabling homeowners to customize the look to suit their decor style.

Additionally, the CIBV-30-2 is equipped with advanced controls that allow for precise temperature management. Optional remote control features are available, giving users added convenience to adjust the settings from a distance. Safety is also a priority; the unit includes built-in safety features to prevent over-heating and ensure reliable operation.

In summary, the Empire Comfort Systems CIBV-30-2 direct vent gas fireplace combines efficiency, flexibility, and beauty, making it an excellent choice for anyone looking to enhance their home’s comfort and style. With its modern design, advanced technology, and user-friendly features, this fireplace stands out as a remarkable solution for heating and ambiance in any living space.