8.Position the completed portion of the casing in the approximate location for installation as the completed assembly will be heavy.

9.Refer to Figure 7, removing protective packing foam from casing front and window. Remove the (1) 3/4" bolt and (1) 1/4" washer from top of window. Remove (1) 3/8" bolt and 1 - 5/8" x 3/4" retaining tab from bottom of window. Remove the window from casing front. Remove the protective sheet of foam from the casing front.

Place the window into the casing front. Attach the top of the window to the casing front with (1) 1/4" washer and (1) 3/4" bolt. Place the 1 -5/8" x 3/4" retaining tab into the locator notch on the bottom of the casing front. Attach the bottom of the window to the casing front by inserting (1) 3/8" bolt through retaining tab and into locator notch.

10.Attach the (4) 1-1/4" x 1/2" retaining tabs to the casing front with (4) 3/8" bolts. The retaining tabs should be positioned downward, from the casing front, top to the casing front, bottom.

11.Refer to Figure 8, attach casing front to outer casing by using the

(4) retaining tabs on the casing front. The (2) top, retaining tabs on the casing front will be placed behind the (2) top, locator tabs on the front of the casing sides. The (2) bottom, retaining tabs will be inserted into the (2) 9/16" slots on the front, leg pads. Place the top, retaining tabs behind the top, locator tabs as you pivot inward the bottom of the casing front in order to insert the bottom, retaining tabs into the slots.

12.The following procedure will provide a snug fit between the casing front and the casing sides. Grasp the right, front leg, push inward on the leg in order to provide a snug fit between the casing front and the casing side. Continue to hold the right, front leg as you completely tighten the (2) 3/8" bolts that attach the leg pad to the right, casing side. Repeat procedure for left, front leg to achieve a snug fit between the casing front and the casing side.

13.Remove the casing front from the outer casing.

Page 6

R-3450

Image 6
Contents Installation Instructions Cast Iron Vented Fireplace HeaterThis is a Heating Appliance Safety Information for Users of LP-GAS LP-GAS Warning OdorQualified Installing Agency Locating and Venting the Fireplace Heater Figures 1, 2Appliance Hardware Package Parts List Page Page Parts List Stone Inlay Replacement of Standard Grille TopInstallation of Optional Stone Inlay Installation of Wire Channel Assembly FigureInside Diameter Outside Diameter Installing a New Main Gas CockGas Supply Figure Never Use an Exposed Flame to Check for LeaksHigh Altitudes Vent Safety Shutoff SystemInsulated Vent Enclosure Figure Piezo Ignitor ButtonCIBV-30 ON/OFF/REMOTE Switch Air Shutter AdjustmentCleaning the Log Set and Firebox Operation of ON/OFF/REMOTE Switch with no AccessoriesWiring Diagram Figure Electric 120 volt Operated Remote Control, FREC-1Installation of Remote Receiver Figure Manual OperationInstallation of Logs and Figure General Glass InformationCleaning Procedure Maintenance & Service InstructionsClean Burner and Control Compartment Operating GuidelinesFor Your Safety Read Before Lighting Pilot and main burner extinguish while in operation Standing PILOT-TROUBLE ShootingFrequent pilot outage problem Glass soots3450 Parts List for CIBV-30 Firebox 3450 Optional Blower CIB-2 Parts List Service Notes

CIBV-30-2 specifications

Empire Comfort Systems has long been a trusted name in the heating industry, providing reliable and efficient heating solutions for homes. One of their standout products is the CIBV-30-2 direct vent gas fireplace, which combines modern technology with aesthetic appeal.

The CIBV-30-2 is designed to deliver warmth and charm to any space while ensuring maximum efficiency. With a compact design, this model is perfect for smaller rooms or areas where space is at a premium. Its direct vent technology allows for the safe exhaust of combustion gases, which enhances indoor air quality. This feature makes the CIBV-30-2 an excellent choice for homeowners looking to enjoy the comfort of a fireplace without the concerns associated with traditional wood-burning options.

One of the key characteristics of the CIBV-30-2 is its capability to provide a steady heat output of up to 30,000 BTUs, ensuring that even the coldest days feel cozy. The fireplace operates on either natural gas or propane, catering to different user preferences and needs. This flexibility makes it an ideal option for various homes and setups. The unit’s efficiency rating is impressive, with a thermal efficiency of over 80%, which means less fuel is consumed while still delivering substantial heat.

Aesthetically, the CIBV-30-2 boasts a stunning view of the flames, thanks to its large glass front. This feature not only enhances the ambiance of the room but also allows easy monitoring of the fire. The fireplace is available with optional decorative rock or log sets, enabling homeowners to customize the look to suit their decor style.

Additionally, the CIBV-30-2 is equipped with advanced controls that allow for precise temperature management. Optional remote control features are available, giving users added convenience to adjust the settings from a distance. Safety is also a priority; the unit includes built-in safety features to prevent over-heating and ensure reliable operation.

In summary, the Empire Comfort Systems CIBV-30-2 direct vent gas fireplace combines efficiency, flexibility, and beauty, making it an excellent choice for anyone looking to enhance their home’s comfort and style. With its modern design, advanced technology, and user-friendly features, this fireplace stands out as a remarkable solution for heating and ambiance in any living space.