Enviro C-11275 owner manual KIT Components

Page 18

Initial Installation

QUALIFIED INSTALLERS ONLY

FIREPLACE HORIZONTAL VENT KIT 50-1235:

Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury.

KIT COMPONENTS:

Qnty

Description

Qnty

Description

 

 

 

 

1

Horizontal direct vent termination cap

4

Wire spacers

 

 

 

 

1

Flue collar adapter

1

4 oz tube Mill-Pac Sealant

 

 

 

 

1

Wall thimble

1

4 oz tube RTV silicone

 

 

 

 

 

1

5’

(190 cm) length of Ø4” (10 cm) double walled flex pipe

12

9/16” tech screws

1

5’

(190 cm) length of Ø65⁄8” (16.8 cm) double walled flex pipe

8

11⁄2” wood screws

 

 

 

 

 

Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.

INSTALLATION INSTRUCTIONS:

1.Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements.

2.Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall.

3.Project a line from the center point of the flue outlet upward and outward to the desired flue outlet location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole from the interior through the exterior wall surfaces.

4.Frame the hole as shown in Figure 29.

5.Trim the wall thimble to match the wall thickness as necessary. Install the wall thimble and secure it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is

greater than 8” (203mm) in depth, the clearance above the flex must be 43⁄8” (111mm)

 

 

 

 

 

6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5

 

 

 

 

 

 

 

 

 

 

cm) provided flue collar adaptor. Press the flue collar into the flue outlet of

 

 

 

 

 

the fireplace so that the Mill-Pac seals the flue collar to the flue outlet.

 

 

 

 

 

7. Stretch both the Ø4” (10 cm) flex vent and the Ø65⁄8” (16.25 cm) flex intake

 

 

 

 

 

liner to the length needed to ensure the flex can be easily connected to the

����

 

 

 

 

vent terminal.

 

 

 

 

 

 

 

 

�������

 

 

 

 

8. Slide the Ø65⁄8” (16.25 cm) flex intake liner

 

 

 

 

 

 

over the flex vent. Install four (4) wire

 

 

 

 

 

 

spacers around the flex pipe. Ensure the

 

 

 

 

 

 

wire spacers are positioned at either end of

 

 

 

 

 

 

the pipes, and at each end of any elbows in

 

 

 

 

 

 

 

 

 

 

 

the liners (refer to Figure 25 and 26).

 

 

 

 

 

 

 

 

 

 

 

9. Install the flex pipe assembly

through

 

 

 

 

 

 

the wall thimble, ensure that this portion

 

 

 

 

 

 

 

 

 

 

 

of pipe slides through the outside wall

 

 

 

 

 

 

far enough to connect onto the vent

 

 

 

 

 

 

Figure 25: Wire Spacers.

termination cap.

 

 

 

Figure 26: Wire Spacer in Place.

18

Image 18
Contents 50-927 Safety Precautions GeneralTable of Contents Codes And Approvals This Enviro DV36 FireplaceSpecifications Installation OptionsFor Your Safety Read Before Operating InstructionsBlue, the fireplace is getting too much To Turn GAS Fireplace OFF Component Sound & ReasonMaintenance And Service Never Operate Fireplace with the glass Removed Bottom latches for glassKit Parts List Completely cooled downConversion Kit Installation Removing valve ScrewRing on valve screw Initial Installation Qualified Installers onlyDo not interfere with the structural integrity of the walls Mantel Clearances Vent Termination Restrictions KIT Components Installation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Two 2 piece wall Vent restrictor is located in the center Being Attached to Wood Assemble Vertical Vent TerminationRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT Min. Manifold Pressure Natural Gas Propane Main OrificeManifold Pressure Max Supply PressureSecondary Installation Empty firebox with grate and locator pinsThird Stage Log Set Installation Never operate the fireplace with the glass door removed Complete log set-up with embersTurn off the gas control knob and allow the unit to cool Back Panel In PlaceKit Contents Installation of Kit Hook Fan Tabs Over Grommets at Unit BackTrouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts List Options DiagramParts Warranty To the DealerWarranty Warranty Installation Data Sheet

C-11275 specifications

Enviro C-11275 is an innovative solution designed specifically for enhancing environmental management and sustainability efforts across various sectors. As industries begin to recognize the importance of minimizing ecological footprints, the demand for advanced technologies and products like Enviro C-11275 has surged. This product is engineered to address pressing environmental challenges, offering a blend of efficiency, reliability, and versatility.

One of the main features of Enviro C-11275 is its eco-friendly formulation, which significantly reduces harmful emissions compared to traditional alternatives. This characteristic aligns with global sustainability goals and regulatory requirements, making it an ideal choice for companies striving to meet their corporate social responsibilities. Moreover, the product is designed to be biodegradable, ensuring that it does not linger in the environment, thereby contributing to soil and water health.

Enviro C-11275 incorporates advanced nanotechnology that enhances its performance. The application of nanoscale additives allows for improved reactivity and a higher efficacy in contaminant removal. This technology ensures that even in small doses, Enviro C-11275 can achieve substantial results in remediation projects, making it cost-effective and efficient.

Furthermore, Enviro C-11275 features a user-friendly application system. Whether applied via spraying, injection, or mixing, the flexibility of its use allows for a wide range of practical applications, from agricultural to industrial cleaning. This adaptability makes it suitable for diverse fields, including manufacturing, waste management, and even residential maintenance.

One of the standout characteristics of Enviro C-11275 is its safety profile. Composed of non-toxic ingredients, it poses minimal risk to human health and the environment, setting it apart from other chemical solutions that often carry hazardous warnings. This safety aspect is paramount, particularly in industries where workers are regularly exposed to potentially harmful substances.

In addition, Enviro C-11275 is backed by extensive research and development. The formulation is the result of rigorous testing and validation, ensuring that it not only performs well but also meets stringent environmental standards. This commitment to excellence provides users with confidence in its efficacy and reliability.

Overall, Enviro C-11275 emerges as a leading contender for businesses focused on environmental stewardship. With its eco-friendly formulation, advanced nanoscale technology, versatile application methods, and strong safety profile, it stands as a testament to the ongoing evolution of sustainable products aimed at protecting our planet for future generations.