Enviro C-11275 owner manual Maintenance And Service

Page 9

Maintenance And Service

ROUTINE MAINTENANCE:

At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips.

Warning: Clearances must be sufficient to allow access for maintenance and service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

The venting system must be periodically examined; it is recommended the examination is done by a qualified agency.

CLEANING THE GLASS:

When the fireplace has cooled, remove the face of the fireplace along with the glass. See MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL. Check the gasket material on the back of the glass, making sure that it is attached and intact.

During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all fireplaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave a slight film behind the glass, a temporary problem. The glass will need cleaning about two weeks after installation. Use a mild glass cleaner and a soft cloth; abrasive cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass should require cleaning no more than two or three times a season. Do not clean the glass when it is hot.

CLEANING THE FIREBOX:

Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and place on a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers as in the

SECONDARY INSTALLATION - LOG SET AND EMBER INSTALLATION section. If new/more embers and rock wool are

required, contact your nearest ENVIRO dealer.

REPLACING THE GLASS:

The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see PARTS LIST). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.

9

Image 9
Contents 50-927 General Safety PrecautionsTable of Contents This Enviro DV36 Fireplace Codes And ApprovalsInstallation Options SpecificationsOperating Instructions For Your Safety Read BeforeBlue, the fireplace is getting too much Component Sound & Reason To Turn GAS Fireplace OFFMaintenance And Service Bottom latches for glass Never Operate Fireplace with the glass RemovedCompletely cooled down Kit Parts ListRemoving valve Screw Conversion Kit InstallationRing on valve screw Qualified Installers only Initial InstallationDo not interfere with the structural integrity of the walls Mantel Clearances Vent Termination Restrictions KIT Components Manufacturer Trade Name Nominal Sizes Installation of Fireplace Horizontal Vent Kit4DSC Two 2 piece wall Vent restrictor is located in the center Being Attached to Wood Vertical Vent Termination AssembleRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT Manifold Pressure Natural Gas Propane Main OrificeMin. Manifold Pressure Max Supply PressureEmpty firebox with grate and locator pins Secondary InstallationThird Stage Log Set Installation Complete log set-up with embers Never operate the fireplace with the glass door removedBack Panel In Place Turn off the gas control knob and allow the unit to coolKit Contents Hook Fan Tabs Over Grommets at Unit Back Installation of KitProblem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Options DiagramParts To the Dealer WarrantyWarranty Warranty Installation Data Sheet

C-11275 specifications

Enviro C-11275 is an innovative solution designed specifically for enhancing environmental management and sustainability efforts across various sectors. As industries begin to recognize the importance of minimizing ecological footprints, the demand for advanced technologies and products like Enviro C-11275 has surged. This product is engineered to address pressing environmental challenges, offering a blend of efficiency, reliability, and versatility.

One of the main features of Enviro C-11275 is its eco-friendly formulation, which significantly reduces harmful emissions compared to traditional alternatives. This characteristic aligns with global sustainability goals and regulatory requirements, making it an ideal choice for companies striving to meet their corporate social responsibilities. Moreover, the product is designed to be biodegradable, ensuring that it does not linger in the environment, thereby contributing to soil and water health.

Enviro C-11275 incorporates advanced nanotechnology that enhances its performance. The application of nanoscale additives allows for improved reactivity and a higher efficacy in contaminant removal. This technology ensures that even in small doses, Enviro C-11275 can achieve substantial results in remediation projects, making it cost-effective and efficient.

Furthermore, Enviro C-11275 features a user-friendly application system. Whether applied via spraying, injection, or mixing, the flexibility of its use allows for a wide range of practical applications, from agricultural to industrial cleaning. This adaptability makes it suitable for diverse fields, including manufacturing, waste management, and even residential maintenance.

One of the standout characteristics of Enviro C-11275 is its safety profile. Composed of non-toxic ingredients, it poses minimal risk to human health and the environment, setting it apart from other chemical solutions that often carry hazardous warnings. This safety aspect is paramount, particularly in industries where workers are regularly exposed to potentially harmful substances.

In addition, Enviro C-11275 is backed by extensive research and development. The formulation is the result of rigorous testing and validation, ensuring that it not only performs well but also meets stringent environmental standards. This commitment to excellence provides users with confidence in its efficacy and reliability.

Overall, Enviro C-11275 emerges as a leading contender for businesses focused on environmental stewardship. With its eco-friendly formulation, advanced nanoscale technology, versatile application methods, and strong safety profile, it stands as a testament to the ongoing evolution of sustainable products aimed at protecting our planet for future generations.