Initial Installation

QUALIFIED INSTALLERS ONLY

VENTING:

This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK METALBESTOS.

A 1” (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a horizontal vent pipe, the clearance to combustibles should be 2” (51 mm) above and 11⁄2” (38 mm) on the sides and bottom. When combustible materials are directly above a 90° elbow, 3” (76 mm) of clearance are necessary (see Figure 28).

Table 7. Vent Pipe Minimum Clearances.

 

Vertical Pipe to

Horizontal Pipe to

Above an Elbow

Above an Elbow

Above Horizontal

Wall Frame 8”

 

the Side Walls

the Sides & Bottom

Above the Unit

Not Above the Unit

Vent Pipe

(203mm) or less

 

 

 

 

 

 

 

Hard

1”

11⁄2”

3”

3”

2”

10”x10”

Pipe

(25.4 mm)

(38.1 mm)

(76.2 mm)

(76.2 mm)

(51 mm)

(25x25cm)

 

 

 

 

 

 

 

Flex

1”

11⁄2”

8”

4 3⁄8”

4 3⁄8”

10”x10”

Pipe

(25.4 mm)

(38.1 mm)

(203 mm)

(111 mm)

(111 mm)

(25x25cm)

 

 

 

 

 

 

 

A 10” (254 mm) x 10” (254 mm) frame (see Figure 29) will assure the proper support and spacing for the vent pipe as it passes through the wall. Installations in Canada require that a wall thimble be used for passing through walls and ceilings. All sealing and vapour barriers must comply with local building codes.

When planning an installation, it is necessary to select the proper length of vent pipe for the particular requirements. The configuration of the venting pipes depends on the locations of walls, ceilings, and studs. However, the pipes cannot be of arbitrary length and arrangement. Because the length of the vertical and horizontal

sections dramatically affects the burning efficiency of the

fireplace, certain

guidelines have been set in INITIAL

INSTALLATION - VENT

CONFIGURATIONS AND

RESTRICTOR SETTINGS.

A two (2) piece wall/

Figure 29. Vent Framing For Wall or Ceiling. ceiling thimble is

included with the stove (see Figure 30).

Venting terminals can not be recessed into a wall or siding.

2" (51mm)

3" (76mm)

 

41 3/4"

 

(1048mm)

 

Figure 28. Vent Pipe Clearances.

WARNING: This gas appliance must not be connected to a chimney flue serving a separate solid-burning appliances.

Figure 30. Wall/Ceiling Thimble provided.

21

Image 21
Contents 50-927 General Safety PrecautionsTable of Contents This Enviro DV36 Fireplace Codes And ApprovalsInstallation Options SpecificationsOperating Instructions For Your Safety Read BeforeBlue, the fireplace is getting too much Component Sound & Reason To Turn GAS Fireplace OFFMaintenance And Service Bottom latches for glass Never Operate Fireplace with the glass RemovedCompletely cooled down Kit Parts ListRemoving valve Screw Conversion Kit InstallationRing on valve screw Qualified Installers only Initial InstallationDo not interfere with the structural integrity of the walls Mantel Clearances Vent Termination Restrictions KIT Components Manufacturer Trade Name Nominal Sizes Installation of Fireplace Horizontal Vent Kit4DSC Two 2 piece wall Vent restrictor is located in the center Being Attached to Wood Vertical Vent Termination AssembleRoof Pitch Minimum Height H Feet Meters Use of Wall Straps Installation of Electrical Wiring for the Optional FAN KIT Manifold Pressure Natural Gas Propane Main OrificeMin. Manifold Pressure Max Supply PressureEmpty firebox with grate and locator pins Secondary InstallationThird Stage Log Set Installation Complete log set-up with embers Never operate the fireplace with the glass door removedBack Panel In Place Turn off the gas control knob and allow the unit to coolKit Contents Hook Fan Tabs Over Grommets at Unit Back Installation of KitProblem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Options DiagramParts To the Dealer WarrantyWarranty Warranty Installation Data Sheet

C-11275 specifications

Enviro C-11275 is an innovative solution designed specifically for enhancing environmental management and sustainability efforts across various sectors. As industries begin to recognize the importance of minimizing ecological footprints, the demand for advanced technologies and products like Enviro C-11275 has surged. This product is engineered to address pressing environmental challenges, offering a blend of efficiency, reliability, and versatility.

One of the main features of Enviro C-11275 is its eco-friendly formulation, which significantly reduces harmful emissions compared to traditional alternatives. This characteristic aligns with global sustainability goals and regulatory requirements, making it an ideal choice for companies striving to meet their corporate social responsibilities. Moreover, the product is designed to be biodegradable, ensuring that it does not linger in the environment, thereby contributing to soil and water health.

Enviro C-11275 incorporates advanced nanotechnology that enhances its performance. The application of nanoscale additives allows for improved reactivity and a higher efficacy in contaminant removal. This technology ensures that even in small doses, Enviro C-11275 can achieve substantial results in remediation projects, making it cost-effective and efficient.

Furthermore, Enviro C-11275 features a user-friendly application system. Whether applied via spraying, injection, or mixing, the flexibility of its use allows for a wide range of practical applications, from agricultural to industrial cleaning. This adaptability makes it suitable for diverse fields, including manufacturing, waste management, and even residential maintenance.

One of the standout characteristics of Enviro C-11275 is its safety profile. Composed of non-toxic ingredients, it poses minimal risk to human health and the environment, setting it apart from other chemical solutions that often carry hazardous warnings. This safety aspect is paramount, particularly in industries where workers are regularly exposed to potentially harmful substances.

In addition, Enviro C-11275 is backed by extensive research and development. The formulation is the result of rigorous testing and validation, ensuring that it not only performs well but also meets stringent environmental standards. This commitment to excellence provides users with confidence in its efficacy and reliability.

Overall, Enviro C-11275 emerges as a leading contender for businesses focused on environmental stewardship. With its eco-friendly formulation, advanced nanoscale technology, versatile application methods, and strong safety profile, it stands as a testament to the ongoing evolution of sustainable products aimed at protecting our planet for future generations.