WARNING; for installation only in a solid fuel burning fireplace with a working flue and
constructed of non-combustible material.
FOR INSTALLATIONS ABOVE 2000 FEET

 

TABLE OF CONTENTS

 

1

Code Approvals

3

2

Specifications

3

3

Assembly and Installation Instruction

4

4 Deciding Where to Locate Your Stove………………………………………………..5

5

Venting

7

6

Installation of Log Sets and Embers

8

7

Operating Instructions

9

8

Routine Maintenance

10

9

Trouble Shooting

11

10

Gas Line Connection

12

11

Electrical Requirements

13

13

Parts and Accessories

14

 

Air Shutter Adjustment

15

14

Warranty

16

15

Installation Data Sheet

17

1. CODE APPROVALS

Canadian Standards Association has tested these appliances, and found them to comply with the established standards for GAS FIRED VENTED ROOM HEATER in CANADA and the USA as follows:

ENVIROGAS EG-40 VENTED ROOM HEATER (EG-40 FPI BV Nat & LPG.)

TESTED TO: ANSI Z21.11.1-1991,Z21.11.1A.-1193 CAN 1-2.1M 86.

2. SPECIFICATIONS

ENVIROGAS 40 (FIREPLACE INSERT) VENTED ROOM HEATER

Vented Type, designated by the suffix BV, this unit must be vented through a conventional chimney with a

certified chimney liner kit.

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bedsitting room.

Must be installed on a non-combustible surface.

Must be installed in accordance with local codes.

If none exist use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

Must be properly connected to a venting system.

In Canada, these appliances are certified for altitudes of 0-2,000 feet and must be derated by 10% for installation at elevations between 2,000 and 4,500 feet.

In the USA, this appliance is certified for elevations up to 2,000 feet. For elevations above 2,000 feet, input should be reduced 4% for every 1,000 feet above sea level.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous

operating conditions and was determined independently of any installed system.

3

Image 3
Contents What to do if YOU Smell GAS N E R S M a N U a LSafety Precautions For Your SafetyGeneral Table of Contents SpecificationsCode Approvals Assembly and Installation Instructions Preparation for InstallationAssembling and Installing Your Envirogas Appliance Deciding Where to Locate Your Stove DimensionsUnit Dimensions Vent Terminal Clearances Venting Fireplace Inserts VentingDo not Place Embers on the Rear Burner Installing the Logset Installing the Glowing EmbersWhat to do if YOU Smell GAS For Your Safety Read Before OperatingOperating Instructions Lighting InstructionsRoutine Maintenance Problem Cause Solution Trouble ShootingNatural GAS Propane GAS Front Burner Never USE AN Open Flame for Leak TestingGAS Line Connection Orifice SIZES, Pressure and BTU’SElectrical Requirements Installing Remote Thermostat or Wall SwitchService Parts available from your local Envirogas Dealer Parts and AccessoriesFuel Type Conversion To a Maximum of Seven Years WarrantyModel EG 40 FPI Installation Data Sheet