Enviro EG-40 owner manual Electrical Requirements, Installing Remote Thermostat or Wall Switch

Page 13

11. ELECTRICAL REQUIREMENTS

The ENVIROGAS EG-40 FPI. BV. will operate without an external electrical power supply. This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners.

The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1,

SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.

NOTE:

Operation of the fan increases the efficiency and heat output of the unit.

This unit is able to operate with a millivolt rated thermostat.

To connect the thermostat use the two- (2) purple wires in the harness. Install the thermostat in series with the purple wires.

CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING; Electrical grounding instructions. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard, and should be plugged directly into a properly grounded three-prong outlet. DO NOT cut or remove the grounding prong from this plug.

INSTALLING REMOTE THERMOSTAT OR WALL SWITCH

RECOMMENDED WIRE SIZE for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire)

1.Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch.

2.Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. Use the terminals marked (TP/TH and TH).

RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE)

WHEN USING WALL THERMOSTAT

WIRE SIZE

MAXIMUM LENGTH

14 GAUGE

100 FEET

16 GAUGE

64 FEET

18 GAUGE

40 FEET

20 GAUGE

18 FEET

13

Image 13
Contents What to do if YOU Smell GAS N E R S M a N U a LFor Your Safety Safety PrecautionsGeneral Specifications Table of ContentsCode Approvals Preparation for Installation Assembly and Installation InstructionsAssembling and Installing Your Envirogas Appliance Dimensions Deciding Where to Locate Your StoveUnit Dimensions Vent Terminal Clearances Venting Fireplace Inserts VentingDo not Place Embers on the Rear Burner Installing the Logset Installing the Glowing EmbersOperating Instructions For Your Safety Read Before OperatingLighting Instructions What to do if YOU Smell GASRoutine Maintenance Problem Cause Solution Trouble ShootingGAS Line Connection Never USE AN Open Flame for Leak TestingOrifice SIZES, Pressure and BTU’S Natural GAS Propane GAS Front BurnerElectrical Requirements Installing Remote Thermostat or Wall SwitchService Parts available from your local Envirogas Dealer Parts and AccessoriesFuel Type Conversion To a Maximum of Seven Years WarrantyModel EG 40 FPI Installation Data Sheet