Hampton Direct H25-NG1, H25-LP1, H25-LP1 Propane installation manual Mination on a siding covered

Page 20

INSTALLATION

3)Attach the 4" dia. fl ex liner to the vent ter- minal ensuring that the fl ex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stainless steel).

4)Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

NOTE: For best results and optimum per- formance with each approved vent- ingsystem,itishighlyrecommended toapply“Mill-Pac”sealant(supplied) to every inner pipe connection. Fail- ure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional.

Note: The pipe seam should be facing down.

Note: To make the installation more aes- thetically pleasing, we recommend framing out a square that the cap can be mounted on.

Note: If installing ter-

mination on a siding covered

wall, a vinyl sid- ing standoff or furring strips must be used to ensure that the termination is not recessed into the

siding. For vinyl siding standoff installation refer to the Dura-Vent Termination instructions.

5)Slide the partially connected pipe and vent terminal assembly through the wall thimbles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 4 corners.

Note: The four screws provided for the vent cap should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

6)A bead of non-hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff.

7)Stretch the 4" dia. fl ex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar.

8)Cut the 4" dia. fl ex liner to the desired size.

Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with.

9)Secure the 4" dia. fl ex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel).

10)Slide the decorative Thimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall.

11)Slide the 90o elbow (crimp end up), the 45o elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. fl ex liner.

12)Install the spring spacers onto the pipe sec- tions.

13)Secure the 4" dia. fl ex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel).

14)Attach the 45o elbow onto the starter collar by sealingwithMill-Pacand/or hightemperature silicone and securing with 3 of the #8 x 1/2" (black) screws.

15)Attach the pipe section to the 45o elbow by sealingwithMill-Pacand/or hightemperature silicone and securing with 3 of the #8 x 1/2" screws (black). Pipe seams should be facing the wall.

16)Attach the 90oelbow onto the pipe section by sealingwithMill-Pacand/or hightemperature silicone and securing with 3 of the #8 x 1/2" screws (black).

17)Slide the adjustable pipe section onto the 90o elbow. Slide the trim collar over the adjust- able pipe sections to cover the joint of the telescopic section.) The fl ex may have to be compressed back in order for the adjustable pipe to properly mate to the elbow. Seal with Mill-Pacand/orhightemperaturesiliconeand secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down.

18)Install the trim collar over the starter collar and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint.

20

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Image 20
Contents H25 Direct Vent Gas Fireplace To the New Owner Unit DimensionsHampton Table of Contents Safety Label Copy of Safety Label for H25-NG1 & H25-LP1Requirements MA Code CO DetectorInstallation Important MessageInstructions Before YOU StartGeneral Safety Information Installation ChecklistClearances to Combustibles This includesOptional FAN Installation Locating Your GAS StoveManufactured Mobile Home Additional Requirements Fan Kit ContainsInstallation Precautions Vent Restrictor PositionRotating 45O Elbow Remove all 4 screws WashersExterior Vent Terminal Locations 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Rigid Pipe Venting Systems AlternateHorizontal CapsVenting Arrangements Dura-Vent Snorkel TerminationHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalVertical Termination with CO-LINEAR Flex System Straight Vertical TerminationsDescription Alternate Approved CapsDV Stove Horizontal Vent KIT Qty. DescriptionMination on a siding covered Optional Components Planning Your venting InstallationMinimum components for a Horizontal Installation Dura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Minimum components for a Dura-Vent Horizontal Installation Below Grade Snorkel InstallationHorizontal Terminations Minimum components for a Dura-Vent Vertical TerminationVertical Terminations Offset Chart Approved for US Installations Only Converting a Factory Built Metal ChimneyAeration Adjustment Cathedral CeilingsHigh Elevation GAS ConnectionClockwise to open Counter-clockwise to close GAS Pipe Pressure TestingValve Description Conversion KIT #434-969 from NG to LP LPG Conversion Kit Contains QtyGlow on logs Installation of the DC Sparker for the H25-1 Unit Only LOG SET Installation Shut off the gas supplyLift off the Cast Top and remove the Glass Front see manual Are fragile, handle with care do not force into positionLogs must be oriented as shown below Remote Control Wall ThermostatOn an interior wall Rear View Decorative Door GrillWiring Diagrams Final CheckFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsNormal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions FAN Maintenance LOG ReplacementGlass Replacement Replacement 946-327 GlassInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve ScrewsParts List Main AssemblyBurner & LOG Assembly Hampton H25-1 Direct Vent Freestanding Gas Stove Hampton H25-1 Direct Vent Freestanding Gas Stove Hampton H25-1 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H25-LP1 Propane, H25-NG1, H25-LP1 specifications

Hampton Direct H25 series, which includes the H25-NG1, H25-LP1, and H25-LP1 Propane models, represents an innovative lineup of gas stoves designed to deliver efficient heating with modern aesthetics. These stoves are perfect for residential and recreational use, providing an economical solution for space heating with exceptional comfort and performance.

One of the standout features of the H25 series is its multi-fuel capability. The H25-NG1 operates on natural gas, while the H25-LP1 and H25-LP1 Propane models utilize liquid propane. This flexibility allows homeowners to select the model that best fits their energy source availability. Each of these units is designed with a powerful heat output, ensuring efficient coverage of living spaces, making them suitable for open floor plan homes and larger areas.

The stoves incorporate advanced combustion technologies, which enable them to burn fuel more efficiently. This leads to less environmental impact, lower emissions, and improved energy use. The H25 series devices utilize a patented firebox design that maximizes heat retention, resulting in extended heating times and better temperature control. Users can expect significant energy savings, as the stoves are engineered to extract more heat from the fuel consumed.

Aesthetically, the H25 series offers an elegant design that adds a contemporary touch to any room. The clean lines and modern finish allow the units to blend seamlessly with various interior styles. Moreover, the units feature large viewing windows that provide a mesmerizing flame display, creating a cozy and inviting atmosphere.

Ease of use is another critical characteristic. Each model comes with user-friendly controls that allow homeowners to adjust the flame height and heat output easily. Additionally, the units have safety features, including automatic shut-off valves, ensuring peace of mind.

The H25 series is engineered for durability, featuring high-quality materials that withstand the test of time. Whether selected for a primary residence or a cozy retreat, the Hampton Direct H25-NG1, H25-LP1, and H25-LP1 Propane models offer an outstanding combination of efficiency, design, and performance that aligns with today’s heating needs.