Hampton Direct H25-NG1, H25-LP1, H25-LP1 Propane installation manual Glow on logs

Page 30

INSTALLATION

7)

Turn control knob to the “OFF” position.

12) Using the Allen wrench as shown in

 

 

Fig.4, rotate the screw clockwise until

8)

Remove the black protection cap by

snug, do not overtighten.

 

hand from the high-low knob (Fig.1).

 

 

 

 

 

 

 

15)

Reverse step 2.

16)

Attach the label "This unit has been

 

converted to LPG" near or on top of the

 

serial # decal.

17)

Replace yellow "NG" label with red

 

"LPG" label.

18)

Check for gas leaks.

19)

Check inlet and outlet pressures.

20)

Check operation of fl ame control.

Fig. 1

9)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to grip

the wrench by the short side.

13)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5).

21) Check for proper fl ame appearance and

glow on logs.

Red o-ring visible

Fig.5

LPG Configuration

Fig.2

10)Check that the screw is clean and if necessary remove dirt.

11)Flip the screw (Fig. 3).

Fig.3

14)Re-assemble the black protection cap (Fig. 6).

Fig. 6

WARNING!

Also check that the pilot and

main burner injectors

are appropriate for the gas type.

30

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Image 30
Contents H25 Direct Vent Gas Fireplace Unit Dimensions HamptonTo the New Owner Table of Contents Safety Label Copy of Safety Label for H25-NG1 & H25-LP1Requirements MA Code CO DetectorInstructions InstallationImportant Message Before YOU StartClearances to Combustibles General Safety InformationInstallation Checklist This includesManufactured Mobile Home Additional Requirements Optional FAN InstallationLocating Your GAS Stove Fan Kit ContainsInstallation Rotating 45O Elbow PrecautionsVent Restrictor Position Remove all 4 screws WashersExterior Vent Terminal Locations 6-5/8 Rigid Pipe Cross Reference Chart Description6-5/8 Rigid Pipe Cross Reference Chart Horizontal Rigid Pipe Venting SystemsAlternate CapsVenting Arrangements Dura-Vent Snorkel TerminationHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalDescription Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT Qty. DescriptionMination on a siding covered Planning Your venting Installation Minimum components for a Horizontal InstallationOptional Components Planning Your Dura-Vent Installation DURA-VENT Termination KITDura-Vent Basic Horizontal Kit # Horizontal Terminations Minimum components for a Dura-Vent Horizontal InstallationBelow Grade Snorkel Installation Minimum components for a Dura-Vent Vertical TerminationVertical Terminations Offset Chart Approved for US Installations Only Converting a Factory Built Metal ChimneyHigh Elevation Aeration AdjustmentCathedral Ceilings GAS ConnectionGAS Pipe Pressure Testing Valve DescriptionClockwise to open Counter-clockwise to close Conversion KIT #434-969 from NG to LP LPG Conversion Kit Contains QtyGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Lift off the Cast Top and remove the Glass Front see manual LOG SET InstallationShut off the gas supply Are fragile, handle with care do not force into positionLogs must be oriented as shown below On an interior wall Remote ControlWall Thermostat Rear View Decorative Door GrillWiring Diagrams Final CheckFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances Glass Replacement FAN MaintenanceLOG Replacement Replacement 946-327 GlassRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue ScrewsParts List Main AssemblyBurner & LOG Assembly Hampton H25-1 Direct Vent Freestanding Gas Stove Hampton H25-1 Direct Vent Freestanding Gas Stove Hampton H25-1 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H25-LP1 Propane, H25-NG1, H25-LP1 specifications

Hampton Direct H25 series, which includes the H25-NG1, H25-LP1, and H25-LP1 Propane models, represents an innovative lineup of gas stoves designed to deliver efficient heating with modern aesthetics. These stoves are perfect for residential and recreational use, providing an economical solution for space heating with exceptional comfort and performance.

One of the standout features of the H25 series is its multi-fuel capability. The H25-NG1 operates on natural gas, while the H25-LP1 and H25-LP1 Propane models utilize liquid propane. This flexibility allows homeowners to select the model that best fits their energy source availability. Each of these units is designed with a powerful heat output, ensuring efficient coverage of living spaces, making them suitable for open floor plan homes and larger areas.

The stoves incorporate advanced combustion technologies, which enable them to burn fuel more efficiently. This leads to less environmental impact, lower emissions, and improved energy use. The H25 series devices utilize a patented firebox design that maximizes heat retention, resulting in extended heating times and better temperature control. Users can expect significant energy savings, as the stoves are engineered to extract more heat from the fuel consumed.

Aesthetically, the H25 series offers an elegant design that adds a contemporary touch to any room. The clean lines and modern finish allow the units to blend seamlessly with various interior styles. Moreover, the units feature large viewing windows that provide a mesmerizing flame display, creating a cozy and inviting atmosphere.

Ease of use is another critical characteristic. Each model comes with user-friendly controls that allow homeowners to adjust the flame height and heat output easily. Additionally, the units have safety features, including automatic shut-off valves, ensuring peace of mind.

The H25 series is engineered for durability, featuring high-quality materials that withstand the test of time. Whether selected for a primary residence or a cozy retreat, the Hampton Direct H25-NG1, H25-LP1, and H25-LP1 Propane models offer an outstanding combination of efficiency, design, and performance that aligns with today’s heating needs.