Hampton Direct H25-LP1 Propane, H25-NG1, H25-LP1 Conversion KIT #434-969 from NG to LP

Page 29

INSTALLATION

CONVERSION KIT #434-969 FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.

LPG Conversion Kit Contains:

Qty. Part #

Description

1904-163 Burner Orifi ce #54

1918-590 Decal "Converted to

LPG"

1908-528 Red "LPG" label

1

904-529

5/32" Allen Key

1

910-037

LPG Injector

 

 

(Pilot Orifi ce)

1

918-480

Instruction Sheet

DC Sparker Kit Contains:

Qty. Part #

Description

1820-475 Bracket DC Sparker

1820-476 Bracket DC Sparker

1904-153 Washer #8 External Star

1 904-330

Nut 8-32 Hex

1904-438 Plug Nylon 0.750 Hole, Black (for H25 only)

1904-531 Bushing Split Plastic

0.500 in.

1904-543 Screw 8-32 x 3/4 Pan Head

2904-553 Screw #8 x 1/2 Type "B", Black Oxide

1

910-073

Spark Generator

 

 

Battery Holder

1

910-074

Spark Generator

 

 

Switch C/W Wire

1910-078 Battery Size AA Energizer En91

2910-199 Clip Wire Holder

1910-903 Wire Fan To Power Cord

Ground 30 in.

904-781 Velcro Hook, Black

Installation of the LPG

Conversion Kit:

1)Shut off the gas supply.

2)P33-4 Only:

a)Remove the louvers (and bay door if it is installed).

b)Open the fl ush door and remove the door.

c)Remove the logs, embers, and brick panels (if used).

d)Remove the 2 screws holding the Burner Assembly to the fi rebox base. Push the Burner Assembly to the left and lift out.

Remove the 2 screws, push Burner

Assembly to the left and lift out.

2)H25-1 Only:

a)Lift off the Cast Top and remove the glass front (refer to Glass Replacement section in the H25-1 manual) and carefully remove the logs and lava rock (refer to Log Installation section in manual).

b)Remove burner by removing the 2 screws on each side and then lifting the burner tray out.

Screws

Note: Use a magnetic type

screwdriver if possible.

Pilot assembly is now accessible for

steps 4) to 9).

3)Pull off the pilot cap to expose the pilot orifi ce.

4)Unscrew the pilot orifi ce with the Allen key and replace with the LPG pilot orifi ce in the kit and replace pilot cap.

5)Remove burner orifi ce with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind

the orifi ce.

Burner Orifi ce

6)Reinstall new burner orifi ce LPG stamped #54 and tighten.

Hampton® H25-1 Direct Vent Freestanding Gas Stove

29

Image 29
Contents H25 Direct Vent Gas Fireplace To the New Owner Unit DimensionsHampton Table of Contents Copy of Safety Label for H25-NG1 & H25-LP1 Safety LabelMA Code CO Detector RequirementsImportant Message InstallationInstructions Before YOU StartInstallation Checklist General Safety InformationClearances to Combustibles This includesLocating Your GAS Stove Optional FAN InstallationManufactured Mobile Home Additional Requirements Fan Kit ContainsInstallation Vent Restrictor Position PrecautionsRotating 45O Elbow Remove all 4 screws WashersExterior Vent Terminal Locations Description 6-5/8 Rigid Pipe Cross Reference Chart6-5/8 Rigid Pipe Cross Reference Chart Alternate Rigid Pipe Venting SystemsHorizontal CapsDura-Vent Snorkel Termination Venting Arrangements+ H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsStraight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemDescription Alternate Approved CapsQty. Description DV Stove Horizontal Vent KITMination on a siding covered Optional Components Planning Your venting InstallationMinimum components for a Horizontal Installation Dura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Below Grade Snorkel Installation Minimum components for a Dura-Vent Horizontal InstallationHorizontal Terminations Minimum components for a Dura-Vent Vertical TerminationVertical Terminations Offset Chart Converting a Factory Built Metal Chimney Approved for US Installations OnlyCathedral Ceilings Aeration AdjustmentHigh Elevation GAS ConnectionClockwise to open Counter-clockwise to close GAS Pipe Pressure TestingValve Description LPG Conversion Kit Contains Qty Conversion KIT #434-969 from NG to LPGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Shut off the gas supply LOG SET InstallationLift off the Cast Top and remove the Glass Front see manual Are fragile, handle with care do not force into positionLogs must be oriented as shown below Wall Thermostat Remote ControlOn an interior wall Rear View Decorative Door GrillFinal Check Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions LOG Replacement FAN MaintenanceGlass Replacement Replacement 946-327 GlassTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve ScrewsMain Assembly Parts ListBurner & LOG Assembly Hampton H25-1 Direct Vent Freestanding Gas Stove Hampton H25-1 Direct Vent Freestanding Gas Stove Hampton H25-1 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H25-LP1 Propane, H25-NG1, H25-LP1 specifications

Hampton Direct H25 series, which includes the H25-NG1, H25-LP1, and H25-LP1 Propane models, represents an innovative lineup of gas stoves designed to deliver efficient heating with modern aesthetics. These stoves are perfect for residential and recreational use, providing an economical solution for space heating with exceptional comfort and performance.

One of the standout features of the H25 series is its multi-fuel capability. The H25-NG1 operates on natural gas, while the H25-LP1 and H25-LP1 Propane models utilize liquid propane. This flexibility allows homeowners to select the model that best fits their energy source availability. Each of these units is designed with a powerful heat output, ensuring efficient coverage of living spaces, making them suitable for open floor plan homes and larger areas.

The stoves incorporate advanced combustion technologies, which enable them to burn fuel more efficiently. This leads to less environmental impact, lower emissions, and improved energy use. The H25 series devices utilize a patented firebox design that maximizes heat retention, resulting in extended heating times and better temperature control. Users can expect significant energy savings, as the stoves are engineered to extract more heat from the fuel consumed.

Aesthetically, the H25 series offers an elegant design that adds a contemporary touch to any room. The clean lines and modern finish allow the units to blend seamlessly with various interior styles. Moreover, the units feature large viewing windows that provide a mesmerizing flame display, creating a cozy and inviting atmosphere.

Ease of use is another critical characteristic. Each model comes with user-friendly controls that allow homeowners to adjust the flame height and heat output easily. Additionally, the units have safety features, including automatic shut-off valves, ensuring peace of mind.

The H25 series is engineered for durability, featuring high-quality materials that withstand the test of time. Whether selected for a primary residence or a cozy retreat, the Hampton Direct H25-NG1, H25-LP1, and H25-LP1 Propane models offer an outstanding combination of efficiency, design, and performance that aligns with today’s heating needs.