Burnham AL SL warranty Service Information, Wiring, Water Temperature Regulation

Page 8

qDo not apply heat to cold inlet.

qIf there is a check valve (sometimes in water meter), backflow preventer or pressure-reducing valve, install an adequate size expansion tank.

G.FILLING THE HEATER

qCompletely fill heater.

qWater connections completed and free of leaks.

qCheck for proper installation of relief valve.

qClose drain valve.

qOpen highest hot water faucet.

qOpen cold water inlet valve and fill system.

H.WIRING

See Figure 1 & 2 and separate TPI control wiring diagrams.

qTPI requires 24V to operate. See TPI installation for details.

qWire either as a heating zone or separate circulator.

qWater heater temperature is controlled by TPI thermostat.

qWARNING: Boiler must have high limit control set no more than 200°F.

SERVICE INFORMATION

WATER TEMPERATURE REGULATION

WARNING: Exposure to 125°F or hotter water can cause scalding injuries. Appropriate caution must be taken when using hot water. Special supervision must be given to those who cannot act quickly such as children, disabled or elderly persons.

The input of heat into the tank is controlled by an immersion thermostat. These automatic controls are set at the factory to maintain a water temperature of 120°F. Note: Although these thermostats are designed to industry standards, they can fail to control temperature properly without any notice, and therefore should be tested periodically for your protection.

DANGER: IF YOU DISCOVER EXTREME HOT WATER COMING FROM THE FAUCET, IMMEDIATELY SHUT OFF THE MAIN SWITCH TO THE BOILER AND CALL COMPETENT SERVICE PERSONNEL. ANY OVERHEATED WATER IS A POTENTIAL HAZARD TO LIFE AND PROPERTY. DO NOT OPER- ATE UNTIL THE SOURCE OF THE PROBLEM HAS BEEN DETERMINED AND ELIMINATED.

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly persons are at the highest risk of being scalded.

See instruction manual before setting temperature at the water heater.

Feel water before bathing or showering.

Proper maintenance is important for any product. It is suggested that the purchaser follow the preventive maintenance program outlined below.



Image 8
Contents Including Warranty Information Indirect Fired Water HeaterSpecifications & Ratings General InformationIndex Installation Guidelines Inspecting and Preparing the Water HeaterLocation Protection from Water DamageInstalling the Removable Heat Exchanger Water Supply ConnectionsTPI Thermostat Installation TPI Wiring ControlsBoiler Supply Connections Filling the HeaterInstallation Checklist Water Temperature Regulation Service InformationWiring Emergency Water Temperature ControlsTemperature Adjustment TPI Control Diagram TPI Control Diagram Installation Diagram Using Zone Valves Installation Diagram Using Separate CirculatorCoil Detail & Tightening Sequence Circulator & Burner Control Wiring Diagrams Wiring for Burner Control L8148EWiring for 4 Zone Valve Zone Valve Wiring DiagramsWiring for 3 Wire Zone Valve Switching relay Wiring Diagrams Switching relay Wiring Diagrams con’t Switching Relay SR-504 with Priority OptionHOW to Obtain Service Assistance Sales Support10/2/1 Limited Warranty TEN 10 Year Limited Tank Replacement Warranty DurationONE 1 Year Limited Parts Warranty Exclusions and LimitationsModel & Serial Number Information Page Page Optional Lifetime Warranty Registration Card Alliance SL Water Heater Serial Number 9 Digits