Regency Wraps C33-NG3 Safety Latch, Door Handle, Remote Control Installation, Remote Wall Switch

Page 13

INSTALLATION

SAFETY LATCH

Secure door in the closed position using the door securing bracket and the screw provided.

Note: Door securing bracket is there for safety.

Note: The door must be kept closed at all times, except during maintenance. The unit must never be operated without the glass in the door, or with the door open.

DOOR HANDLE

Attach spring handle by rotating counter clock- wise onto rod. Ensure that the spring fi ts into the entire length of the rod.

REMOTE CONTROL

INSTALLATION

Use the Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver (protection from extreme heat is very important). Run wiresfrom the fi replace to that location. Use the Thermostat Wire Table.

2)Connect the two wires to the gas valve. See diagram below.

CAUTION

Do not wire the millivolt remote control wires to the 120V AC wires.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

REMOTE WALL

SWITCH

1)Run the wire through the opening in the rear of the unit. Be careful not to damage any wires.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run use the Thermostat Wire Table.

2)Connect the wire to the wall switch and install into receptacle box.

CAUTION

Do not wire the millivolt wall switch for gas appliance to the 120V AC wires

WALL THERMOSTAT

INSTALLATION

Regency® offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

Connect the wires as per the wiring diagram. Use the Thermostat Wire Table to determine the maximum wire length.

CAUTION

Do not wire the millivolt wall ther- mostat wires to the 120V AC wires

Note: Preferableifthethermostatisinstalled on an interior wall.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50

Ft.

16 GA.

32

Ft.

18 GA.

20

Ft.

20 GA.

12

Ft.

22 GA.

9

Ft.

 

 

 

 

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:

1)Clocking the appliance to ensure the cor- rect fi ring rate (rate noted on label) after 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage to the unit is not the responsibility of the manufacturer and will not be covered by the warranty.

Regency® CLASSIC C33-3 Freestanding Gas Stove

13

Image 13
Contents C33 Classic Freestanding Gas Stove To the New Owner Table of Contents Safety Label MA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Before YOU StartC33-3 Reference Dimensions Optional FAN InstallationClearances to Combustibles This includesWiring Pedestal AssemblyDraft Hood Optional Outside AIRVenting GAS Connection GAS Pipe Pressure TestingSystem Data High ElevationValve Installation DC SparkerWith Pedestal With Bottom ShieldOperation Test for LOG SET Flue Spillage InstallationRemote Control Installation Safety LatchRemote Wall Switch Wall Thermostat InstallationWiring Diagrams Normal Operating Sounds of GAS Appliances Do Not Attempt To Clean The Glass While It is still hot Shutdown ProcedureOperating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingGeneral Vent Maintenance MaintenanceAeration Adjustment Pilot AdjustmentGlass Replacement LOG ReplacementClean any fingerprints off before turning the unit on GOLD-PLATED DoorsInstalling Removing Valve AssemblyTo remove valve from valve assembly, continue Main Assembly Parts ListBurner & Logs Base Options Regency Classic C33-3 Freestanding Gas Stove Regency Classic C33-3 Freestanding Gas Stove Regency Classic C33-3 Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information