Regency Wraps C33-NG3, C33-LP3 installation manual Optional Outside AIR, Draft Hood, Venting

Page 9

INSTALLATION

LEG AND BOTTOM SHIELD ASSEMBLY

These instructions apply to the steel leg, painted cast leg and the gold plated cast leg. It will be easier to attach the legs to the stove if it is tipped on its back (preferably on a soft surface to prevent scratching).

1)Remove the 4 bolts in the underside of the base and discard.

2)Put the bottom shield up against the bottom of the stove and loosely install the four sup- plied bolts and washers into the threaded holes in the four corners of the bottom the unit. Once the bolts are started, slip the leg under the washer and tighten the bolts.

3)Hook up wires to Burner ON/OFF switch and valve assembly as per pedestal assembly diagram (diagram 1).

4)Level the stove by adjusting the levelling bolts in the bottom of each leg.

OPTIONAL

OUTSIDE AIR

If needed, outside air for combustion can be brought in either through the bottom of the ped- estal or through the rear plate of the pedestal.

The pedestal cover plate must be installed when using outside combustion air. Loosen the 4 screws on the rear of the pedestal and slide the cover plate over them. Slide the plate to the left to center it and tighten down the 4 screws.

Outside Air Through

Pedestal Bottom

Once you have properly marked the position of your unit as outlined in "General Informa- tion" and "Clearances to Combustibles", cut a minimum 3 inch diameter hole though the fl oor directly under your pedestal base to the outside. Pipe fresh air into the pedestal area by using a minimum 3" duct pipe with a mesh grill at the outside termination.

Note: Blanking plate combustion air hole is 4" diameter.

Rear View

Outside Air Through

Pedestal Rear

Remove the blanking plate from the rear of the pedestal cover plate and bend the two tabs out 90 degrees. Pipe fresh air into the pedestal area by using a minimum 3" duct pipe with a mesh grill at the outside termination. Attach the pipe to the tabs with screws.

Note: The hole in the rear pedestal cover plate is 4" diameter.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

DRAFT HOOD

The heater has a draft hood built into its back. It must not be altered or obstructed, and the unit must be installed so that the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the burner.

VENTING

This heater is a vented appliance and must be connected to a chimney/fl ue in accordance with installation codes.

Note: The rear cover plate is only attached when outside air is being used. Do not install it when using room air for combustion.

For your safety this heater is equipped with a ventsafetyswitch.Thisthermallyactuatedswitch is located within the draft hood and will detect either a blocked chimney or backdraft condition where the chimney fl ow has reversed and will react by shutting off the gas supply.

Note: Thespillswitchismanuallyresettable and comes from the factory in the open position. Before trying to start up the unit, make sure the red button on the spill switch is pushed in.

Venting Requirements

Four inch diameter vent is required. B-Vent, ClassAorMasonrywithalinerareallacceptable. Follow all venting manufacturer’s requirements and local building codes. For altitudes above 2000 ft. we recommend that a minimum fl ue height of 12 ft. is used.

Note: Proper sizing of gas vents is critical to proper operation of all gas stoves and fireplaces. Ensure that proper sizing tables or vent manufacturers instructions are followed.

Side View

Regency® CLASSIC C33-3 Freestanding Gas Stove

9

Image 9
Contents C33 Classic Freestanding Gas Stove To the New Owner Table of Contents Safety Label MA Code CO Detector RequirementsGeneral Safety Information InstallationInstallation Checklist Before YOU StartC33-3 Reference Dimensions Optional FAN InstallationClearances to Combustibles This includesWiring Pedestal AssemblyOptional Outside AIR Draft HoodVenting GAS Connection GAS Pipe Pressure TestingSystem Data High ElevationValve Installation DC SparkerWith Pedestal With Bottom ShieldOperation Test for LOG SET Flue Spillage InstallationRemote Control Installation Safety LatchRemote Wall Switch Wall Thermostat InstallationWiring Diagrams Normal Operating Sounds of GAS Appliances Shutdown Procedure Do Not Attempt To Clean The Glass While It is still hotOperating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingGeneral Vent Maintenance MaintenanceAeration Adjustment Pilot AdjustmentGlass Replacement LOG ReplacementClean any fingerprints off before turning the unit on GOLD-PLATED DoorsRemoving Valve Assembly InstallingTo remove valve from valve assembly, continue Main Assembly Parts ListBurner & Logs Base Options Regency Classic C33-3 Freestanding Gas Stove Regency Classic C33-3 Freestanding Gas Stove Regency Classic C33-3 Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information