Regency F2402M manual Minimum Clearance to Combustible Materials, Floor Protector

Page 7

INSTALLATION

AUSTRALIA ONLY

IMPORTANT

Use only the instructions and clearance dimensions on this page for heaters to be installed in Australia.

The Regency F2402M has been tested by theAHHATesting Laboratory and conforms to AS/NZS 2918:200, Report No. ATL19-04.

The Regency F2402M has been tested with the fl ue kits listed below. A default fl ue kit as listed in AS/NZS 2918:2001 may also be used.

These are the only fl ue kits certifi ed for use with this heater for installation in Australia.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Please read the section below carefully as clearances depend on whether the airmate or the rear heat defl ector is installed on the stove.

Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.

Residential Installation Clearances to Combustible Walls

Unit

From Unit

From Corner

From Flue Center-Line

 

A

B

C

D

E

F

 

 

 

 

 

 

 

Medium F2402M with Airmate*

450mm

125mm

150mm

755mm

290mm

445mm

with Rear Deflector*

450mm

150mm

225mm

755mm

315mm

555mm

 

 

 

 

 

 

 

*Airmate fitted, and 900mm long half round enamelled mild steel flue shield or half perforated decromesh flue shield fitted

*Rear firebox shield extension fitted, and full length half perforated decromesh flue surround or 900mm long half round enamelled mild steel flue shield fitted.

Flue systems tested:

Acorn Special Insulated

FLOMET Super Single

Shamic 1A

Floor Protector:

6mm thick fi bre cement sheet with thermal conductivity 0.41 W/m degree K underneath heater extending 300mm in front and 200 mm from the sides of the fi rebox opening.

Regency Freestanding Woodstove

7

Image 7
Contents Model F2402M Please Keep These Instructions For Future ReferenceModular Parts Regency Fireplace ProductTable of Contents Safety Label Unit Dimensions Residential Installation InstallationModular Installation Options Minimum Clearance to Combustible Materials Residential Installation Clearances to Combustible WallsFloor Protector 152 mm 45* 1143 mm 127 mm 45 1143 mm With Rear Deflector Minimum Alcove Clearance to Combustible MaterialsFloor Protection 15 381 mm 165 mm 27 685 mm 13 330 mm 54 1371 mm 49 1244 mmPedestal Assembly Stove Assembly Prior to InstallationRear Heat Deflector Assembly Airmate AssemblyLeg and Bottom Shield Assembly STEP-BY-STEP Chimney Connector InstallationMasonry Fireplace Masonry ChimneyFactory Built Chimney Method a 12 304.8 mm Clearance to Combustible Wall Member Combustible Wall Chimney Connector PASS-THROUGHSRecommended Flue Height Recommended Heights for Woodstove FlueElevation Example a Example b Mobile Home Installation Flue Baffle Listed Components For Mobile Home InstallationInstallation Canadian InstallationsDoor Handle Brick InstallationSTEP-BY-STEP Optional Accessories Installation Glass InstallationBlower/Fan First Fire Operating InstructionsOperating Instructions Draft ControlASH Disposal Safety GuidelinesSafety Precautions FAN OperationMaintenance Description 846-515 Parts ListStove Main Assembly DescriptionPEDESTAL, Bottom Shield & LEG Options Firebrick Regency Freestanding Woodstove Regency Freestanding Woodstove Regency Freestanding Woodstove Warranty Lifetime WarrantyWestern Australia Eastern Australia Distributors