INSTALLATION
AUSTRALIA ONLY
IMPORTANT
Use only the instructions and clearance dimensions on this page for heaters to be installed in Australia.
The Regency F2402M has been tested by theAHHATesting Laboratory and conforms to AS/NZS 2918:200, Report No.
The Regency F2402M has been tested with the fl ue kits listed below. A default fl ue kit as listed in AS/NZS 2918:2001 may also be used.
These are the only fl ue kits certifi ed for use with this heater for installation in Australia.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the rear heat defl ector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Residential Installation Clearances to Combustible Walls
Unit | From Unit | From Corner | From Flue | |||
| A | B | C | D | E | F |
|
|
|
|
|
|
|
Medium F2402M with Airmate* | 450mm | 125mm | 150mm | 755mm | 290mm | 445mm |
with Rear Deflector* | 450mm | 150mm | 225mm | 755mm | 315mm | 555mm |
|
|
|
|
|
|
|
*Airmate fitted, and 900mm long half round enamelled mild steel flue shield or half perforated decromesh flue shield fitted
*Rear firebox shield extension fitted, and full length half perforated decromesh flue surround or 900mm long half round enamelled mild steel flue shield fitted.
Flue systems tested:
Acorn Special Insulated
FLOMET Super Single
Shamic 1A
Floor Protector:
6mm thick fi bre cement sheet with thermal conductivity 0.41 W/m degree K underneath heater extending 300mm in front and 200 mm from the sides of the fi rebox opening.
Regency Freestanding Woodstove | 7 |