INSTALLATION

OPTIONAL WALL

OPTIONAL REMOTE

THERMOSTAT

CONTROL

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing

A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:

Note: Preferable if the thermostat is installed on an interior wall.

Regency offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 240 V wires.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

15.24

m

16 GA.

9.75

m

18 GA.

6.10

m

20 GA.

3.66

m

22 GA.

2.71

m

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location, use Thermostat Wire Table.

2)Connect the wires as per the wiring diagram above.

CAUTION

Do not connect the millivolt

remote control wires to

the 240V wires.

3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

correctly. This includes:

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.

12

Regency F38-2 Freestanding Gas Stove

Image 12
Contents Manual Please Keep These Instructions For Future ReferenceTo the New Owner Table of Contents Safety Label Regency Gas FireplaceInstallation General Safety InformationGeneral Information Before YOU StartInstallation Checklist Clearances to CombustiblesDraft Diverter FlueingGAS Pipe Pressure Testing GAS ConnectionFlueing Requirements T. Valve DescriptionConversion KIT# 731-968 from NG to LPG LPG Conversion Kit Contains Qty Description#52 and tighten Reverse steps 3 toAeration Adjustment LOG SET InstallationF38-2 with 38 mj F02-47 A02-65 D02-46 E02-45 B02-56 C02-44 Front Door Installation Test for Flue SpillageFinal Check 14 GA 15.24 16 GA 18 GA 20 GA 22 GAWiring Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsPilot Adjustment Normal Operating Sounds GAS AppliancesMaintenance Maintenance InstructionsLOG Replacement Glass ReplacementFAN Maintenance Installing GlassRemoving Valve Parts List Main AssemblyPart# Aust. New Zealand Description Burner & LOG Assembly Door Assembly Warranty Warranty Lifetime