FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

A) This appliance has a pilot which must be lighted

a qualified service technician. Force or attempted

by hand, following the instructions below

repair may result in a fire or explosion.

exactly.

D) Do not use this appliance if any part has been under

B) BEFORE LIGHTING smell all around the appliance

water. Immediately call a qualified service techni-

area for gas. Be sure to smell next to the floor

cian to inspect the appliance and to replace any part

because some gas is heavier than air and will

of the control system and any gas control which has

settle on the floor.

been under water.

WHAT TO DO IF YOU SMELL GAS

This appliance needs fresh air for safe operation and

- Do not try to light any appliance

must be installed so there are provisions for adequate

- Do not touch any electric switch, do not use any

combustion and ventilation air.

phone in your building

CAUTION: Hot while in operation. Do not touch.

- Immediately call your gas supplier from a

neighbors phone. Follow the gas supplier’s in-

Severe Burns may result. Due to high surface

structions.

temperatures keep children, clothing and

- If you cannot reach your gas supplier, call the

furniture, gasoline and other liquids having

fire department.

fammablevaporsaway.Keepburnerandcontrol

C)Use only your hand to push in or turn the gas compartment clean. See installation and

control knob. Never use tools. If the knob will not operatinginstructionsaccompanyingappliance.

push in or turn by hand, don’t try to repair it, call

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this

Release knob and it will pop back up. Pilot should

label.

 

 

 

remain lit. If it goes out, repeat steps 3) and 4).

1) Push in gas control knob slightly and turn

If knob does not pop up when released, stop and

clockwise

to “OFF”. Knob cannot be turned

immediately call your service technician or gas

from “PILOT” to “OFF” unless knob is pushed in

supplier.

 

 

 

 

 

 

 

 

 

 

 

 

slightly. Do

not

force.

 

If the pilot will not stay lit after several tries, turn the

2) Wait five (5) minutes to clear out any gas. If you

gas control knob to “OFF” and call your service

then smell gas STOP! follow “B” in the safety

technician or gas supplier.

 

 

 

 

 

 

 

 

 

 

 

 

information above on this label. If you don’t smell

5) Turn gas control knob counterclockwise

 

 

to “ON”.

gas, go to the next step.

 

6) Use rocker switch to operate main burner.

3) Turn knob

on

gas control

counterclockwise

PILOT BURNER

 

 

 

 

 

 

 

 

 

 

 

 

to “PILOT”.

 

 

VEILLEUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4) Push in control

knob all the

way and hold in.

THERMOPILE

 

 

 

 

 

 

 

 

 

 

 

 

Immediately push black button on spark igniter

ELEMENT

 

 

 

 

 

 

 

 

 

Gas Inlet

 

 

 

 

 

 

 

 

 

 

 

until pilot

lights. Continue to

hold the control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMO-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

knob in for about 1/2 minute after the pilot is lit.

ELECTRIQUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO TURN OFF GAS APPLIANCE

1) Push in the gas control knob slightly and turn

clockwise

to “OFF”. Do not force.

2)Turn off all electric power to the appliance if service is to be performed.

You may shut off the pilot during prolonged non use periods to conserve fuel.

DO NOT REMOVE THIS INSTRUCTION PLATE

908-649c

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING:

DO NOT SPRAY AEROSOLS IN THE VICINITY OF

THIS APPLIANCE WHILE IN OPERATION.

Regency F38-2 Freestanding Gas Heater

15

Image 15
Contents Please Keep These Instructions For Future Reference ManualTo the New Owner Table of Contents Regency Gas Fireplace Safety LabelBefore YOU Start InstallationGeneral Safety Information General InformationFlueing Installation ChecklistClearances to Combustibles Draft DiverterT. Valve Description GAS Pipe Pressure TestingGAS Connection Flueing RequirementsReverse steps 3 to Conversion KIT# 731-968 from NG to LPGLPG Conversion Kit Contains Qty Description #52 and tightenAeration Adjustment LOG SET InstallationF38-2 with 38 mj F02-47 A02-65 D02-46 E02-45 B02-56 C02-44 Test for Flue Spillage Front Door Installation14 GA 15.24 16 GA 18 GA 20 GA 22 GA Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Pilot AdjustmentGlass Replacement MaintenanceMaintenance Instructions LOG ReplacementInstalling Glass FAN MaintenanceRemoving Valve Parts List Main AssemblyPart# Aust. New Zealand Description Burner & LOG Assembly Door Assembly Warranty Lifetime Warranty