Regency F38-LPG2, F38-NG2 installation manual Removing Valve

Page 19

MAINTENANCE

If your valve requires maintenance or replace- ment, follow these instructions:

NOTE: Always shut off the gas supply before removing the valve.

1)Open front pedestal door and unhook chain. You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn't scratch the paint. See diagram below.

REMOVING VALVE

4) Remove the two outside frame pieces by 9) Carefully lift the burner tray assembly out. removing two screws per side. See diagram

below.

2)Undo the six screws holding the control panel in place.

3)Disconnect all wires from the back of the panel and then remove panel. You should lay the panel on a soft cloth so it doesn't get marked up. See diagram below.

5) Carefully remove the logs and lava rock.

6)At this point you should disconnect the gas at the valve.

7)Remove the burner by removing the two 1/4" hex head screws. See diagram be- low.

Note: Use a magnetic type screwdriver.

8)Remove eight 1/4" hex head screws holding the burner tray assembly in place.

10)To replace the burner tray assembly, simply reverse these instructions.

Regency F38-2 Freestanding Gas Heater

19

Image 19
Contents Please Keep These Instructions For Future Reference ManualTo the New Owner Table of Contents Regency Gas Fireplace Safety LabelBefore YOU Start InstallationGeneral Safety Information General InformationFlueing Installation ChecklistClearances to Combustibles Draft DiverterT. Valve Description GAS Pipe Pressure TestingGAS Connection Flueing RequirementsReverse steps 3 to Conversion KIT# 731-968 from NG to LPGLPG Conversion Kit Contains Qty Description #52 and tightenLOG SET Installation Aeration AdjustmentF38-2 with 38 mj F02-47 A02-65 D02-46 E02-45 B02-56 C02-44 Test for Flue Spillage Front Door Installation14 GA 15.24 16 GA 18 GA 20 GA 22 GA Final CheckWiring Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Pilot AdjustmentGlass Replacement MaintenanceMaintenance Instructions LOG ReplacementInstalling Glass FAN MaintenanceRemoving Valve Main Assembly Parts ListPart# Aust. New Zealand Description Burner & LOG Assembly Door Assembly Warranty Lifetime Warranty