Lopi DVL Insert EF II owner manual Fine Tuning the EMBER-FYRE Burner

Page 25

Finalizing the Installation

25

FINE TUNING THE EMBER-FYRE™ BURNER

Each installation is affected by altitude, vent configuration, and fuel quality. Because of this, the restrictor and air shutter may need to be fine tuned to each installation. Follow the hints below to fine- tune the burner for optimum performance and aesthetics.

Restrictor Adjustment:

Only those installations determined to be over-drafting require this adjustment. See the instructions on page 14 for details.

Air Shutter Hints:

For more glow, open the air shutter, however, this will make the flames more blue.

For yellow flames, close the air shutter, however, this may create less glow.

Correct

Lifting Flames

Ghosting Flames

Flickering Flames

 

Burner Ports

 

 

Burner

(holes)

 

 

The flames should burn right off the top of the burner ports (if they are too blue, adjust the air control).

Lifting flames indicate insufficient draft (restrictor is set too high).

Ghosting flames indicate

Flickering, short flames

insufficient air (restrictor set too

indicate excessive draft

high, air shutter shut down, or

(move air shutter to a higher

other venting error).

position).

Warning: If the vent configuration is installed incorrectly the vent may cause the flames inside the heater to lift or “ghost” – a dangerous situation. Inspect the flames after installation to insure proper performance. If the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the heater and contact the dealer for information on remedying the problem.

8.Replace the glass.

9.Attach the face following the directions included with the face.

NOTE: If using the Classic Arched, Artisan, Metropolitan or Victorian Lace Face you must use the face mounting brackets included with the heater (SKU 225-20054). See page 11 for details.

10.Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your dealer for a remedy.

New Brackets

Old Brackets

11. Give this manual to the home owner and fully explain the operation of this heater.

© Travis Industries

4060111

100-01174

Image 25
Contents Travis Industries, Inc DVL Insert EFIntroduction Important Information 2IntroductionSave Your Bill of Sale 4060111Table of Contents If YOU Smell GAS Safety PrecautionsDo not place anything inside Heating Specifications Features Installation OptionsDimensions Natural Gas PropaneInstallation for qualified installers only Fireplace Requirements Top Convection DeflectorLeveling Bolts Hearth RequirementsFactory-Built Metal Wood-Burning Fireplace Requirements Mantel Clearances ClearancesFace Height Width Face SizingGas Line Location Gas Line RequirementsGas Inlet Pressure Altitude Considerations Vent RequirementsVent Restrictor Vent InstallationVent Location Vent Configurations Inlet & Exhaust Re-LineVent Connector Removal and Installation Vent Connector Removal Surround Panel Installation Installation Without Surround PanelsElectrical Connection Installation of the On/Off Switch and RheostatGlass Frame Removal and Installation Finalizing the InstallationFinalizing the Installation Install the logs Log Set InstallationInstalling the Rock Wool Install the twigs, ember chunk, kibbles, and rock woolAir Shutter Adjustment Steps for Finalizing the InstallationPilot Flame Inspection Fine Tuning the EMBER-FYRE Burner Before You Begin 26OperationLocation of Controls Starting The Pilot Flame Operation28Operation Adjusting the Flame HeightStarting the Heater for the First Time Turning the Heater On and OffOperation29 Adjusting the Blower SpeedNormal Operating Sounds Normal Operating OdorsYearly Service Procedure 30MaintenanceMaintaining Your Heaters Appearance Troubleshooting Table MaintenanceHow this Heater Works 32MaintenanceWhat Turns the Main Burners On and Off What Prevents Gas BuildupWiring Diagram Maintenance33Replacement Parts List Safety Label Safety LabelYears 1 & 2 Coverage Parts & Labor Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyLP Conversion Instructions Burner ReplacementFollow the directions below to replace the orifices Optional Equipment for qualified installers onlyTo adjust the pilot flame, turn this screw Note if totally Firebacks Optional Equipment for qualified installers only Accent Light Important Installation Note for Models Using the FirebacksAccent Light Operation Lower Surround Panel Index

DVL Insert EF II specifications

The Lopi DVL Insert EF II is a remarkable heating solution that combines advanced technology with elegant design. As a part of Lopi’s prestigious line of gas inserts, the DVL Insert EF II is specifically engineered to provide efficient and reliable heating for homeowners. With an array of features, it stands out as an optimal choice for those looking to enhance their living space while maintaining energy efficiency.

One of the main features of the DVL Insert EF II is its exceptional heating efficiency. This insert is designed to provide a high heat output while minimizing energy consumption. With an impressive thermal efficiency rating, it significantly reduces heating costs and ensures that your home remains warm and inviting during the colder months. The insert is capable of heating areas up to 1,800 square feet, making it ideal for both large and small rooms.

The DVL Insert EF II boasts an advanced direct vent technology, which allows for efficient combustion while maintaining indoor air quality. This technology facilitates the intake of external air for combustion, ensuring that exhaust gases are safely vented outside, hence creating a clean and safe environment indoors. Additionally, this direct vent system enables flexible installation options, making it adaptable to various home layouts.

Another significant characteristic of the DVL Insert EF II is its impressive design. The insert features a contemporary aesthetic with clean lines and large viewing glass, allowing for an unobstructed view of the flame. The realistic flame effects and ember bed create a warm ambiance, making it a focal point in any room. Homeowners can also choose from various finishes and decorative options, ensuring that the insert complements their home decor.

Equipped with user-friendly controls, the DVL Insert EF II allows for easy adjustment of flame height and heat output. The intuitive remote control provides added convenience, enabling users to manage their comfort with just the touch of a button. Additionally, the insert is designed for easy maintenance, featuring removable components that simplify cleaning and upkeep.

In summary, the Lopi DVL Insert EF II exemplifies efficiency, elegance, and innovation. With its high thermal efficiency, direct vent technology, and stylish design, this gas insert is an excellent investment for any home. It not only provides warmth and comfort but also enhances the aesthetic appeal of your living space while promoting energy efficiency. Experience the warmth of the Lopi DVL Insert EF II and transform your home into a cozy retreat.