GAS CONTROL VALVE

The gas control knob is located on the right hand side of the firebox behind the right side exterior brick panel.

1)Remove the right side exterior brick panel.

Right Side Exterior Brick Panel

2)Loosen the 2 screws that hold the right side heat shield in place.

Heat

Shield

3)Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox).

MATCHING REMOTE

HANDSET & CONTROL

BOX ID CODE

The Remote Control Handset has a set of unique ID codes that is pre-programmed into its memory. This set of ID codes helps to differentiate one Remote Control Handset from another so that only the control box with a matching ID code will respond to the appropriate Remote Control Handset.

To ensure the remote control is matched to the receiver correctly, please follow the steps below:

1.Install the 2 x AAA alkaline batteries into the Remote Control.

2.Unplug and re-plug the power cord. The power cord is located on the left hand side of the appliance and will be plugged into the receptacle.

3.Press and hold the PROG and FAN buttons simultaneously for up to 20 seconds. During this time, the remote will display LC while it is transmitting codes to the receiver.

4.Once it is successfully transmitted, wait for 20 seconds and press the ON/OFF button on the remote control once and the burners will come on.

If is does not work the fi rst time, repeat steps 2 and 3.

5.The remote control is now programmed to the receiver and the appliance can now be operated with it.

The control box will only learn the Remote ID codes during the fi rst 30 seconds after power is appliedand will ignore thisspecial commandfrom the Remote after the fi rst 30 seconds.

NOTE: This must only be performed by a quali- fi ed installer.

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

5)Verify that the venting and cap are unobstructed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

FIRST FIRE

The FIRST FIRE in your heater is part of the paint curing process. To ensure the paint is properly cured,it is recommendedyou burnyourfireplace for at least four (4) hours the fi rst time.

When fi rst operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: The main burner will always start on "HIGH" and resume it's last setting after 20 seconds of operation.

NOTE: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOTATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

OPERATION

Regency® L676E Direct Vent Gas Fireplace

33

Image 33
Contents Libertytm L676E Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelMA Code CO Detector RequirementsUnit Dimensions General Safety Information InstallationInstallation Checklist Important Message Save These InstructionsLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeatwave Duct KIT Heat Release KITClearances Mantel LEG Clearances Mantel ClearancesImportant Header must be metal stud Framing & FinishingPrior to Installation Unit AssemblyVent Restrictor Position Venting IntroductionFactory set for NG units Factory set for LP units= Clearance to permanently closed window *min /30cm Exterior Vent Termination RequirementsHorizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems58DVA-16AB 8 Rigid Pipe Cross Reference ChartL676 & L900 Direct Vent Fireplace Allowable Horizontal Terminations Vent Restrictor SettingHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Rigid Pipe Allowable Vertical TerminationsUnit Installation with Horizontal Termination This allows for small adjustments Unit Installation With Vertical TerminationDiagram Minimum VentAstrocap XL Unit InstallationTesting Pilot AdjustmentAeration GAS Line Installation AdjustmentBACK-UP Battery Installation Battery WiresHeat Shield Handle with care. do not Force Into Position Brick Panel InstallationExterior Brick Panel Installation 03-25 LOG SET InstallationComplete Log Set Installation Do not cut the ground terminal off under any circumstances Wiring DiagramGAS Control Valve Operating InstructionsMatching Remote Handset & Control BOX ID Code Operating InstructionsShutdown Procedure Lighting ProcedureOperation During Power Outage Backup BatteryCopy of Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Backup Battery Latch Location Control BOX ReplacementD E Back-up Battery Power ReceptacleRemove the exterior brick panels Valve Tray ReplacementBack-up Battery shown Wire Harness Connectors Wire Harness DisconnectedHarness Bottom Brick PanelValve Tray Parts List Main AssemblyDescription Burner & LOG Assembly Regency L676E Direct Vent Gas Fireplace Regency L676E Direct Vent Gas Fireplace Regency L676E Direct Vent Gas Fireplace Warranty Limited Lifetime WarrantyInstaller Please complete the following information

L676E-LP, L676E-NG specifications

Regency L676E-LP and L676E-NG are two remarkable gas fireplaces designed to elevate any living space with their blend of efficiency, aesthetics, and innovative technology. These models stand out with their versatile design, suitable for both new and existing homes, while offering homeowners an exceptional heating experience.

Both the L676E-LP (liquid propane) and L676E-NG (natural gas) fireplaces showcase a stylish contemporary design that fits seamlessly into modern and traditional decors alike. With a sleek and elegant appearance, these fireplaces serve as a stunning focal point in any room, creating a cozy ambiance while efficiently warming the space.

One of the key features of the L676E series is its high-efficiency rating. These gas fireplaces are engineered to produce substantial heat while minimizing energy consumption. Equipped with advanced energy-efficient technology, they provide a significant reduction in utility costs compared to traditional heating methods. The L676E models also come with an impressive heat output, making them suitable for larger areas, effectively maintaining a comfortable environment during colder months.

The L676E fireplaces are built with a powerful burner system that ensures even heat distribution throughout the room. The innovative technology allows for adjustable flame heights, enabling users to customize the intensity of the fire to suit their mood. The clean-burning design also contributes to an environmentally-friendly experience, producing minimal emissions and reducing the carbon footprint.

Another standout characteristic is the ease of use and convenience offered by both models. Featuring an intuitive remote control system, users can adjust settings effortlessly. The option for thermostat control further enhances comfort, allowing the fireplace to maintain a consistent temperature automatically.

Safety is paramount in the design of the L676E-LP and L676E-NG fireplaces. They are equipped with advanced safety features, including an automatic shutdown system and a protective glass front to prevent accidental burns. Additionally, their durable construction ensures long-lasting performance and reliability.

In summary, the Regency L676E-LP and L676E-NG gas fireplaces merge cutting-edge technology with elegant design. Their high efficiency, impressive heating output, and safety features make them a valuable addition to any home, providing both comfort and style. Whether for new construction or retrofitting an existing space, these models represent an ideal choice for homeowners seeking a blend of functionality and sophistication.