Regency L676E-LP, L676E-NG installation manual Maintenance

Page 36

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1) Alwaysturnoffthegasvalvebeforecleaning.

 

For relighting, refer to lighting instructions.

 

Keep the burner and control compartment

 

clean by brushing and vacuuming at least

 

once a year. When cleaning the logs, use a

 

soft clean paint brush as the logs are fragile

 

and easily damaged.

2)

Clean appliance and door with a damp

 

cloth (never when unit is hot). Never use

 

an abrasive cleaner. The glass should be

 

cleaned with a gas fi replace glass cleaner.

 

The glass should be cleaned when it

 

starts looking cloudy.

3) The heater is fi nished in a heat resistant

 

paint and should only be refinished with heat

 

resistant paint. Regency® uses StoveBright

 

Paint - Metallic Black #6309.

4)

Make a periodic check of burner for proper

 

position and condition. Visually check the

 

flame of the burner periodically, making sure

 

the fl ames are steady; not lifting or fl oating.

 

If there is a problem, call a qualifi ed service

 

person.

5) The appliance and venting system must be

 

inspected before use, and at least annually,

 

by a qualifi ed fi eld service person, to ensure

 

that the fl ow of combustion and ventilation

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semiannually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2)Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation,suchaswaterdropletsforming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

DOOR GLASS

Your Regency® fi replace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approvedglasscleaneravailableatallauthorized dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

*Do not clean when the glass is hot.

*The use of substitute glass will void all product warranties.

*Care must be taken to avoid breakage of the glass.

*Do not strike or abuse the glass.

*Do not operate this fi replace without the glass front or with a cracked or broken glass front.

*Wear gloves when removing damaged or broken glass.

*Replacement of the glass panel(s) should be done by a licensed or qualifi ed service per son.

GLASS REPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.

Replacement glass is shipped already installed into the door frame.

MAINTENANCE

air is not obstructed.

Note: Never operate the appliance without the glass properly secured in place.

6)Donotusethisapplianceifanyparthasbeen under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

7)In the event this appliance has been serviced check that the vent-air system has been properly resealed & reinstalled in accordance with the manufacturer's instructions.

8)Verify operation after servicing.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's performance which is not covered under warranty.

CAUTION: Wear gloves when removing damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

GLASS GASKET

If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-155).

36

Regency® L676E Direct Vent Gas Fireplace

Image 36
Contents Libertytm L676E Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceHeatwave Duct KIT Heat Release KITClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing Important Header must be metal studUnit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionFactory set for NG units Factory set for LP unitsExterior Vent Termination Requirements = Clearance to permanently closed window *min /30cmVenting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Allowable Vertical Terminations Rigid PipeUnit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLPilot Adjustment TestingAeration GAS Line Installation AdjustmentBACK-UP Battery Installation Battery WiresHeat Shield Brick Panel Installation Handle with care. do not Force Into PositionExterior Brick Panel Installation LOG SET Installation 03-25Complete Log Set Installation Wiring Diagram Do not cut the ground terminal off under any circumstancesOperating Instructions GAS Control ValveMatching Remote Handset & Control BOX ID Code Operating InstructionsLighting Procedure Shutdown ProcedureOperation During Power Outage Backup BatteryFor Your Safety Read Before Lighting Copy of Lighting Plate InstructionsMaintenance Control BOX Replacement Backup Battery Latch LocationBack-up Battery Power Receptacle D EValve Tray Replacement Remove the exterior brick panelsWire Harness Connectors Wire Harness Disconnected Back-up Battery shownHarness Bottom Brick PanelValve Tray Parts List Main AssemblyDescription Burner & LOG Assembly Regency L676E Direct Vent Gas Fireplace Regency L676E Direct Vent Gas Fireplace Regency L676E Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

L676E-LP, L676E-NG specifications

Regency L676E-LP and L676E-NG are two remarkable gas fireplaces designed to elevate any living space with their blend of efficiency, aesthetics, and innovative technology. These models stand out with their versatile design, suitable for both new and existing homes, while offering homeowners an exceptional heating experience.

Both the L676E-LP (liquid propane) and L676E-NG (natural gas) fireplaces showcase a stylish contemporary design that fits seamlessly into modern and traditional decors alike. With a sleek and elegant appearance, these fireplaces serve as a stunning focal point in any room, creating a cozy ambiance while efficiently warming the space.

One of the key features of the L676E series is its high-efficiency rating. These gas fireplaces are engineered to produce substantial heat while minimizing energy consumption. Equipped with advanced energy-efficient technology, they provide a significant reduction in utility costs compared to traditional heating methods. The L676E models also come with an impressive heat output, making them suitable for larger areas, effectively maintaining a comfortable environment during colder months.

The L676E fireplaces are built with a powerful burner system that ensures even heat distribution throughout the room. The innovative technology allows for adjustable flame heights, enabling users to customize the intensity of the fire to suit their mood. The clean-burning design also contributes to an environmentally-friendly experience, producing minimal emissions and reducing the carbon footprint.

Another standout characteristic is the ease of use and convenience offered by both models. Featuring an intuitive remote control system, users can adjust settings effortlessly. The option for thermostat control further enhances comfort, allowing the fireplace to maintain a consistent temperature automatically.

Safety is paramount in the design of the L676E-LP and L676E-NG fireplaces. They are equipped with advanced safety features, including an automatic shutdown system and a protective glass front to prevent accidental burns. Additionally, their durable construction ensures long-lasting performance and reliability.

In summary, the Regency L676E-LP and L676E-NG gas fireplaces merge cutting-edge technology with elegant design. Their high efficiency, impressive heating output, and safety features make them a valuable addition to any home, providing both comfort and style. Whether for new construction or retrofitting an existing space, these models represent an ideal choice for homeowners seeking a blend of functionality and sophistication.