Regency L676E-LP, L676E-NG Rigid Pipe Venting Systems, Basic Horizontal & Vertical Terminations

Page 16

INSTALLATION

RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS

INSTALLATION

Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as gal- vanized fi nish.

The minimum components required for a basic horizontal termination are:

1Horizontal Termination Cap

190o Elbow

1Rigid Pipe Adaptor

1Wall Thimble

1Length of pipe to suit wall thickness

The minimum components required for a basic vertical termination are:

1Vertical Termination Cap

1Rigid Pipe Adaptor

1Lengths of pipe to adequately penetrate roof

1Ceiling Firestop

1Flashing

1Storm Collar

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

*A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.

Alternate

Horizontal Termination

Caps

WARNING:

Do not combine venting components from different venting systems.

Use of the the AstroCap XLTM is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS and Selkirk Direct- Temp systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

IMPORTANT NOTE

The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.

Only the AstroCap XL and Snorkels are certified for horizontal terminations.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCap XLTM is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®Direct Vent GS and Selkirk Direct-Temp. AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

16

Regency® L676E Direct Vent Gas Fireplace

Image 16
Contents Libertytm L676E Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalRequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceHeatwave Duct KIT Heat Release KITClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing Important Header must be metal studUnit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionFactory set for NG units Factory set for LP unitsExterior Vent Termination Requirements = Clearance to permanently closed window *min /30cmVenting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o Elbows Allowable Vertical Terminations Rigid PipeUnit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLPilot Adjustment TestingAeration GAS Line Installation AdjustmentBattery Wires BACK-UP Battery InstallationHeat Shield Brick Panel Installation Handle with care. do not Force Into PositionExterior Brick Panel Installation LOG SET Installation 03-25Complete Log Set Installation Wiring Diagram Do not cut the ground terminal off under any circumstancesOperating Instructions GAS Control ValveMatching Remote Handset & Control BOX ID Code Operating InstructionsLighting Procedure Shutdown ProcedureOperation During Power Outage Backup BatteryFor Your Safety Read Before Lighting Copy of Lighting Plate InstructionsMaintenance Control BOX Replacement Backup Battery Latch LocationBack-up Battery Power Receptacle D EValve Tray Replacement Remove the exterior brick panelsWire Harness Connectors Wire Harness Disconnected Back-up Battery shownHarness Bottom Brick PanelValve Tray Main Assembly Parts ListDescription Burner & LOG Assembly Regency L676E Direct Vent Gas Fireplace Regency L676E Direct Vent Gas Fireplace Regency L676E Direct Vent Gas Fireplace Warranty Warranty Limited LifetimeInstaller Please complete the following information

L676E-LP, L676E-NG specifications

Regency L676E-LP and L676E-NG are two remarkable gas fireplaces designed to elevate any living space with their blend of efficiency, aesthetics, and innovative technology. These models stand out with their versatile design, suitable for both new and existing homes, while offering homeowners an exceptional heating experience.

Both the L676E-LP (liquid propane) and L676E-NG (natural gas) fireplaces showcase a stylish contemporary design that fits seamlessly into modern and traditional decors alike. With a sleek and elegant appearance, these fireplaces serve as a stunning focal point in any room, creating a cozy ambiance while efficiently warming the space.

One of the key features of the L676E series is its high-efficiency rating. These gas fireplaces are engineered to produce substantial heat while minimizing energy consumption. Equipped with advanced energy-efficient technology, they provide a significant reduction in utility costs compared to traditional heating methods. The L676E models also come with an impressive heat output, making them suitable for larger areas, effectively maintaining a comfortable environment during colder months.

The L676E fireplaces are built with a powerful burner system that ensures even heat distribution throughout the room. The innovative technology allows for adjustable flame heights, enabling users to customize the intensity of the fire to suit their mood. The clean-burning design also contributes to an environmentally-friendly experience, producing minimal emissions and reducing the carbon footprint.

Another standout characteristic is the ease of use and convenience offered by both models. Featuring an intuitive remote control system, users can adjust settings effortlessly. The option for thermostat control further enhances comfort, allowing the fireplace to maintain a consistent temperature automatically.

Safety is paramount in the design of the L676E-LP and L676E-NG fireplaces. They are equipped with advanced safety features, including an automatic shutdown system and a protective glass front to prevent accidental burns. Additionally, their durable construction ensures long-lasting performance and reliability.

In summary, the Regency L676E-LP and L676E-NG gas fireplaces merge cutting-edge technology with elegant design. Their high efficiency, impressive heating output, and safety features make them a valuable addition to any home, providing both comfort and style. Whether for new construction or retrofitting an existing space, these models represent an ideal choice for homeowners seeking a blend of functionality and sophistication.