Omnitron Systems Technology 564 SS owner manual 2Maintenance, Glass Cleaning

Page 22

2 2Maintenance

Glass Cleaning

The glass may be cleaned with a non- abrasive cleaner. To clean the inside of the glass, simply remove the glass frame, place it on a non-scratching surface, and clean the inside surface.

If the outside surface of the glass frame requires cleaning, follow the directions below to remove the outer glass frame and screen.

WARNING: do not operate the fireplace without the glass frame and screen in place.

Six sets of tabs hold the glass (and glass gasket) in place. Four of these tabs are at the corners, two are at the top and bottom of the glass frame.

Gasket

 

Tabs

Inner Frame

Outer Frame

REMOVAL INSTRUCTIONS: carefully bend the tabs out with needle-nose pliers (there are tabs on the inner and outer frame - the center tabs only have tabs on the inner frame). Do not pry these tabs, this may cause the glass to crack.

REPLACEMENT INSTRUCTIONS: carefully bend the tabs inward, making sure the tabs contact the gasket, not the glass. Bend the tab inwards 30°- do not over-bend the tabs.

With the outer glass frame and screen removed, the outer surface of the glass may be cleaned.

Inner glass frame

The optional screen is sandwiched between the inner and outer glass frame.

Outer glass frame

© Travis Industries

4070626

100-01189_000

Image 22
Contents Operation Maintenance SS FireplaceIntroduction Important Information Installation WarningsIntroduction Save Your Bill of SaleFeatures Table of ContentsHeating Specifications Safety Precautions If YOU Smell GASDo not place anything inside Before You Begin OperationLocation of Controls Starting The Pilot Flame Starting the Fireplace for the First Time Adjusting the Flame HeightTurning the Fireplace On and Off Normal Operating Sounds Adjusting the Optional Blower SpeedNormal Operating Odors Yearly Service Procedure 0MaintenanceMaintaining Your Fireplaces Appearance Maintenance1 Grill Installation and Removal2Maintenance Face Installation and RemovalGlass Frame Removal and Installation Re-Attaching the Glass Frame4Maintenance Log Set Installation Log Set Overview6Maintenance Rear Log InstallationRight Log Installation 8Maintenance Left Log InstallationLeft Twig Installation Right Twig Installation Maintenance2 Ember InstallationGlass Cleaning Maintenance Troubleshooting TableWhat Turns the Main Burners On and Off How this Fireplace WorksWhat Prevents Gas Buildup Millivolt Wiring stock configuration Wiring DiagramReplacement Parts List Optional Blower Wiring HarnessYears 3 Through 5 Coverage Parts & Labor Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyOptional Equipment AccessoriesBlower Firebacks Index Index

564 SS specifications

Omnitron Systems Technology's iConverter 564 SS is a robust and versatile solution designed for organizations that require reliable media conversion and networking capabilities. This compact device specializes in converting Gigabit Ethernet signals over fiber optic cables, enabling long-distance data transmission while ensuring minimal signal loss. The iConverter 564 SS supports a wide range of applications including telecommunications, enterprise networks, and industrial automation, providing a crucial link for various networking demands.

One of the standout features of the iConverter 564 SS is its modular design. The device supports a range of pluggable modules that can accommodate various types of fiber interfaces, including multimode and single-mode options. This flexibility allows users to customize their setups according to specific network requirements, whether they need to connect to legacy systems or modern high-speed networks.

In terms of technology, the iConverter 564 SS employs advanced optical components and sophisticated signal processing algorithms to ensure high performance. The device is capable of supporting connections at distances up to 120 kilometers, depending on the fiber type and environmental conditions. This makes it suitable for extensive networks across campuses or across cities.

Additionally, the iConverter 564 SS features a user-friendly management interface, which simplifies the configuration and monitoring of network performance. With support for SNMP, users can easily manage their network environments and receive alerts for any potential issues. This proactive approach helps maintain network reliability and uptime.

The iConverter 564 SS is also built with robust environmental specifications. It operates efficiently in wide temperature ranges and is designed to withstand various industrial conditions. This durability ensures that the device can be deployed in both controlled environments and harsher outdoor settings.

Security is another priority for the iConverter 564 SS, which supports various encryption and authentication protocols, safeguarding data during transmission. This is essential for businesses handling sensitive information.

In summary, Omnitron Systems Technology's iConverter 564 SS is a versatile media converter that excels in performance, flexibility, and reliability. With its modular design, advanced technologies, comprehensive management tools, and strong security features, it is a dedicated solution for organizations seeking to enhance their network capabilities while ensuring future scalability.