Omnitron Systems Technology 564 SS owner manual Maintenance, Troubleshooting Table

Page 23

 

 

 

 

Maintenance

2 3

 

 

 

 

Troubleshooting Table

 

 

 

 

 

 

 

 

 

 

 

Problem:

Possible Cause:

Don't Call for Service

 

 

 

 

 

Until You:

 

 

 

 

 

 

 

 

 

Pilot

Will Not

A gas shut off valve is turned off

Check all gas shut off valves

 

 

The gas control knob isn't turned to "PILOT"

See "Starting the Pilot Light" Step C

 

 

Light

 

 

The valve control knob isn't pushed in

See "Starting the Pilot Light" Step C

 

 

 

 

The igniter wasn't pressed repeatedly

See "Starting the Pilot Light" Step C

 

 

 

 

No Propane in Tank

Check Tank Level

 

 

 

 

 

 

 

 

 

Main

Burners

The pilot light has gone out

See "Starting the Pilot Light"

 

 

The gas control valve is turned to "PILOT" or "OFF"

See "Starting the Pilot Light"

 

 

Will

Not Start

 

 

The ON/OFF switch is turned to "OFF"

Turn the ON/OFF switch to "ON"

 

 

 

 

The remote control is not working correctly

See the remote control instructions

 

 

 

 

The thermostat is disconnected or set too low

See "Thermostat Operation"

 

 

 

 

 

 

 

 

 

Remote Control

The pilot light has gone out

See "Starting the Pilot Light"

 

 

The gas control valve is turned to "PILOT" or "OFF"

See "Starting the Pilot Light"

 

 

Does Not Work

 

 

The ON/OFF switch is turned to "OFF"

Turn the ON/OFF switch to "ON"

 

 

 

 

The remote is too far away from the fireplace

Use the remote closer to the fireplace

 

 

 

 

The remote control receiver is turned "Off"

See the remote control instructions

 

 

 

 

One of the two remote control batteries is dead

See the remote control instructions

 

 

 

 

 

 

Thermostat Does

The pilot light has gone out

See "Starting the Pilot Light"

 

 

Not Work

The gas control valve is turned to "PILOT" or "OFF"

See "Starting the Pilot Light"

 

 

The ON/OFF switch is turned to "OFF"

Turn the ON/OFF switch to "ON"

 

 

 

 

The thermostat is set too low

See "Thermostat Operation"

Fireplace Will

Not Distribute

H e a t

The fireplace is not getting electricity

Check the breaker switch

The fireplace is not up to temperature

See "Operating Your Fireplace"

Pilot Goes Out

The gas supply has been shut off

Keep the gas supply turned on

 

 

Intermittently

 

 

 

 

 

Flames Are Too

The fireplace has just been started

This is normal - see "Starting the Fireplace

 

for the First Time"

Blue

 

Improper air shutter adjustment

Adjust Air Shutter - contact your dealer

 

 

 

 

Flames Are Too

The flame height may be turned too low

Turn the flame height to "HI" -

 

See "Adjusting the Flame Height"

Short (Under 6")

 

 

 

 

 

 

Thin Layer of

The logs or coals are placed incorrectly

See "Log Set Installation"

 

 

Soot Covers the Improper air shutter adjustment

Adjust Air Shutter - contact your dealer

Glass

© Travis Industries

4070626

100-01189_000

Image 23
Contents SS Fireplace Operation MaintenanceSave Your Bill of Sale Installation WarningsIntroduction Introduction Important InformationHeating Specifications Table of ContentsFeatures If YOU Smell GAS Safety PrecautionsDo not place anything inside Location of Controls OperationBefore You Begin Starting The Pilot Flame Turning the Fireplace On and Off Adjusting the Flame HeightStarting the Fireplace for the First Time Normal Operating Odors Adjusting the Optional Blower SpeedNormal Operating Sounds Maintaining Your Fireplaces Appearance 0MaintenanceYearly Service Procedure Grill Installation and Removal Maintenance1Face Installation and Removal 2MaintenanceRe-Attaching the Glass Frame Glass Frame Removal and Installation4Maintenance Log Set Overview Log Set InstallationRear Log Installation 6MaintenanceRight Log Installation Left Log Installation 8MaintenanceLeft Twig Installation Right Twig Installation Ember Installation Maintenance2Glass Cleaning Troubleshooting Table MaintenanceWhat Prevents Gas Buildup How this Fireplace WorksWhat Turns the Main Burners On and Off Optional Blower Wiring Harness Wiring DiagramReplacement Parts List Millivolt Wiring stock configurationYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborBlower Firebacks AccessoriesOptional Equipment Index Index

564 SS specifications

Omnitron Systems Technology's iConverter 564 SS is a robust and versatile solution designed for organizations that require reliable media conversion and networking capabilities. This compact device specializes in converting Gigabit Ethernet signals over fiber optic cables, enabling long-distance data transmission while ensuring minimal signal loss. The iConverter 564 SS supports a wide range of applications including telecommunications, enterprise networks, and industrial automation, providing a crucial link for various networking demands.

One of the standout features of the iConverter 564 SS is its modular design. The device supports a range of pluggable modules that can accommodate various types of fiber interfaces, including multimode and single-mode options. This flexibility allows users to customize their setups according to specific network requirements, whether they need to connect to legacy systems or modern high-speed networks.

In terms of technology, the iConverter 564 SS employs advanced optical components and sophisticated signal processing algorithms to ensure high performance. The device is capable of supporting connections at distances up to 120 kilometers, depending on the fiber type and environmental conditions. This makes it suitable for extensive networks across campuses or across cities.

Additionally, the iConverter 564 SS features a user-friendly management interface, which simplifies the configuration and monitoring of network performance. With support for SNMP, users can easily manage their network environments and receive alerts for any potential issues. This proactive approach helps maintain network reliability and uptime.

The iConverter 564 SS is also built with robust environmental specifications. It operates efficiently in wide temperature ranges and is designed to withstand various industrial conditions. This durability ensures that the device can be deployed in both controlled environments and harsher outdoor settings.

Security is another priority for the iConverter 564 SS, which supports various encryption and authentication protocols, safeguarding data during transmission. This is essential for businesses handling sensitive information.

In summary, Omnitron Systems Technology's iConverter 564 SS is a versatile media converter that excels in performance, flexibility, and reliability. With its modular design, advanced technologies, comprehensive management tools, and strong security features, it is a dedicated solution for organizations seeking to enhance their network capabilities while ensuring future scalability.