Omnitron Systems Technology 564 SS Table of Contents, Features, Heating Specifications

Page 3

Introduction

3

Table of Contents

Introduction and Important Information

 

Introduction

2

Important Information

2

Installation Warnings

2

Features

3

Heating Specifications

3

Safety Precautions

 

Safety Precautions

4

Operation

 

Before You Begin

6

Location of Controls

6

Starting The Pilot Flame

6

Starting the Fireplace for the First Time

8

Turning the Fireplace On and Off

8

Adjusting the Flame Height

8

Adjusting the Optional Blower Speed

9

Normal Operating Sounds

9

Normal Operating Odors

9

Maintenance

 

Maintaining Your Fireplace's Appearance

10

Yearly Service Procedure

10

Grill Installation and Removal

11

Face Installation and Removal

12

Glass Frame Removal and Installation

13

Log Set Installation

15

Glass Cleaning

22

Troubleshooting Table

23

How this Fireplace Works

24

Wiring Diagram

25

Replacement Parts List

25

Warranty

 

Warranty

24

Optional Equipment

 

Optional Equipment List

27

Index

 

Index

28

Features

Works During Power Outages (millivolt system)

Convenient Operating Controls

Optional Thermostat or Remote Control

Variable-Rate Heat Output

Realistic "Wood Fire" Look

Low Maintenance

Optional Blower for Effective Heat Distribution

Heating Specifications

 

Natural Gas

Propane

Approximate Heating Capacity (in square feet)*

950

950

Maximum BTU Input Per Hour

20,500

20,500

Minimum BTU Input on Low

5,100

4,200

Steady State Efficiency** (with blowers on)

76.5 %

74.2 %

*Heating capacity will vary with floor plan, insulation, and outside temperature.

**Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system.

© Travis Industries

4070626

100-01189_000

Image 3
Contents SS Fireplace Operation MaintenanceSave Your Bill of Sale Installation WarningsIntroduction Introduction Important InformationTable of Contents FeaturesHeating Specifications If YOU Smell GAS Safety PrecautionsDo not place anything inside Operation Before You BeginLocation of Controls Starting The Pilot Flame Adjusting the Flame Height Starting the Fireplace for the First TimeTurning the Fireplace On and Off Adjusting the Optional Blower Speed Normal Operating SoundsNormal Operating Odors 0Maintenance Yearly Service ProcedureMaintaining Your Fireplaces Appearance Grill Installation and Removal Maintenance1Face Installation and Removal 2MaintenanceRe-Attaching the Glass Frame Glass Frame Removal and Installation4Maintenance Log Set Overview Log Set InstallationRear Log Installation 6MaintenanceRight Log Installation Left Log Installation 8MaintenanceLeft Twig Installation Right Twig Installation Ember Installation Maintenance2Glass Cleaning Troubleshooting Table MaintenanceHow this Fireplace Works What Turns the Main Burners On and OffWhat Prevents Gas Buildup Optional Blower Wiring Harness Wiring DiagramReplacement Parts List Millivolt Wiring stock configurationYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborAccessories Optional EquipmentBlower Firebacks Index Index

564 SS specifications

Omnitron Systems Technology's iConverter 564 SS is a robust and versatile solution designed for organizations that require reliable media conversion and networking capabilities. This compact device specializes in converting Gigabit Ethernet signals over fiber optic cables, enabling long-distance data transmission while ensuring minimal signal loss. The iConverter 564 SS supports a wide range of applications including telecommunications, enterprise networks, and industrial automation, providing a crucial link for various networking demands.

One of the standout features of the iConverter 564 SS is its modular design. The device supports a range of pluggable modules that can accommodate various types of fiber interfaces, including multimode and single-mode options. This flexibility allows users to customize their setups according to specific network requirements, whether they need to connect to legacy systems or modern high-speed networks.

In terms of technology, the iConverter 564 SS employs advanced optical components and sophisticated signal processing algorithms to ensure high performance. The device is capable of supporting connections at distances up to 120 kilometers, depending on the fiber type and environmental conditions. This makes it suitable for extensive networks across campuses or across cities.

Additionally, the iConverter 564 SS features a user-friendly management interface, which simplifies the configuration and monitoring of network performance. With support for SNMP, users can easily manage their network environments and receive alerts for any potential issues. This proactive approach helps maintain network reliability and uptime.

The iConverter 564 SS is also built with robust environmental specifications. It operates efficiently in wide temperature ranges and is designed to withstand various industrial conditions. This durability ensures that the device can be deployed in both controlled environments and harsher outdoor settings.

Security is another priority for the iConverter 564 SS, which supports various encryption and authentication protocols, safeguarding data during transmission. This is essential for businesses handling sensitive information.

In summary, Omnitron Systems Technology's iConverter 564 SS is a versatile media converter that excels in performance, flexibility, and reliability. With its modular design, advanced technologies, comprehensive management tools, and strong security features, it is a dedicated solution for organizations seeking to enhance their network capabilities while ensuring future scalability.