Omnitron Systems Technology 564 SS owner manual Starting The Pilot Flame

Page 7

Operation

Starting The Pilot Flame

The pilot flame is required to ignite the main burners (it also plays a safety role). It should be

left on once lit. It will stay lit unless the gas a control valve is turned to "OFF". However, the

pilot will go out if the gas is shut off, the propane tank runs out (or low) or if the stove malfunctions. If the pilot turns off frequently, call your dealer for information. To start the pilot follow the directions below:

WARNING:

When lighting or re-lighting the pilot,

the glass must be removed (see page

b

 

1 0 ) .

 

a Remove the glass (see page 10 for details).

bPush the gas control knob in slightly and turn it to the "OFF" position. The knob will not

turn from "ON" to "OFF" unless the knob is

depressed slightly. Wait five minutes to let c any gas that may have accumulated inside

the firebox escape. If you smell leaking gas, follow the directions on the cover "IF YOU SMELL GAS".

cTurn the gas control knob to the "PILOT" position and press the knob in, this will allow

gas to flow to the pilot light. Press the

button on the pilot igniter repeatedly until d you see the pilot light.

WARNING:

If the pilot does not light after 15 seconds, release the knob and call your dealer for service. Do not attempt to light pilot until service has been performed .

e

N O T E :

You may wish to remove the log set to gain a better view of the pilot (see page 1 5 ) .

d Keep the gas control knob depressed for 30 seconds once it is lit.

f

e Release the gas control knob. If the pilot goes out, repeat step C. If the pilot refuses to stay lit, call your dealer for service. With the pilot lit, proceed to step “f”.

fReplace the glass.

g Turn the gas control knob counter-clockwise

to "ON". The pilot is now lit and the heater g can be turned on and off.

7

5 minutes

PILOT

IGNITER

30 seconds

?

© Travis Industries

4070626

100-01189_000

Image 7
Contents SS Fireplace Operation MaintenanceSave Your Bill of Sale Installation WarningsIntroduction Introduction Important InformationFeatures Table of ContentsHeating Specifications If YOU Smell GAS Safety PrecautionsDo not place anything inside Before You Begin OperationLocation of Controls Starting The Pilot Flame Starting the Fireplace for the First Time Adjusting the Flame HeightTurning the Fireplace On and Off Normal Operating Sounds Adjusting the Optional Blower SpeedNormal Operating Odors Yearly Service Procedure 0MaintenanceMaintaining Your Fireplaces Appearance Grill Installation and Removal Maintenance1Face Installation and Removal 2MaintenanceRe-Attaching the Glass Frame Glass Frame Removal and Installation4Maintenance Log Set Overview Log Set InstallationRear Log Installation 6MaintenanceRight Log Installation Left Log Installation 8MaintenanceLeft Twig Installation Right Twig Installation Ember Installation Maintenance2Glass Cleaning Troubleshooting Table MaintenanceWhat Turns the Main Burners On and Off How this Fireplace WorksWhat Prevents Gas Buildup Optional Blower Wiring Harness Wiring DiagramReplacement Parts List Millivolt Wiring stock configurationYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborOptional Equipment AccessoriesBlower Firebacks Index Index

564 SS specifications

Omnitron Systems Technology's iConverter 564 SS is a robust and versatile solution designed for organizations that require reliable media conversion and networking capabilities. This compact device specializes in converting Gigabit Ethernet signals over fiber optic cables, enabling long-distance data transmission while ensuring minimal signal loss. The iConverter 564 SS supports a wide range of applications including telecommunications, enterprise networks, and industrial automation, providing a crucial link for various networking demands.

One of the standout features of the iConverter 564 SS is its modular design. The device supports a range of pluggable modules that can accommodate various types of fiber interfaces, including multimode and single-mode options. This flexibility allows users to customize their setups according to specific network requirements, whether they need to connect to legacy systems or modern high-speed networks.

In terms of technology, the iConverter 564 SS employs advanced optical components and sophisticated signal processing algorithms to ensure high performance. The device is capable of supporting connections at distances up to 120 kilometers, depending on the fiber type and environmental conditions. This makes it suitable for extensive networks across campuses or across cities.

Additionally, the iConverter 564 SS features a user-friendly management interface, which simplifies the configuration and monitoring of network performance. With support for SNMP, users can easily manage their network environments and receive alerts for any potential issues. This proactive approach helps maintain network reliability and uptime.

The iConverter 564 SS is also built with robust environmental specifications. It operates efficiently in wide temperature ranges and is designed to withstand various industrial conditions. This durability ensures that the device can be deployed in both controlled environments and harsher outdoor settings.

Security is another priority for the iConverter 564 SS, which supports various encryption and authentication protocols, safeguarding data during transmission. This is essential for businesses handling sensitive information.

In summary, Omnitron Systems Technology's iConverter 564 SS is a versatile media converter that excels in performance, flexibility, and reliability. With its modular design, advanced technologies, comprehensive management tools, and strong security features, it is a dedicated solution for organizations seeking to enhance their network capabilities while ensuring future scalability.