Weil-McLain GV90+ manual Monthly, Check boiler interior piping, Check venting system

Page 7

GV90+ gas-fired water boiler — User’s Information Manual

User maintenance procedures (continued)

MONTHLY

Maintenance

Check boiler interior piping

1.Remove boiler jacket top.

2.Visually inspect for leaks around internal piping, circulators, relief valve and other fittings. Immediately call a qualified service technician to repair any leaks.

Have leaks fixed at once by a qualifed service technician. Continual fresh makeup water will reduce boiler life. Minerals can build up in sections, reducing heat transfer, overheating cast iron, and causing section failure.

Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to boiler and system components can occur, resulting in possible severe personal injury, death or substantial property damage.

Check venting system

1.Visually inspect the flue gas vent piping for any signs of blockage, leakage or deterioration of the piping. Notify your qualified service technician at once if you find any problem.

Failure to inspect the vent system as noted above and have them repaired by a qualifed service technician can result in vent system failure, causing severe per-

sonal injury or death.

Check automatic air vents (if used — use automatic air vents with diaghragm-type expansion tanks only)

1.See Figure 3.

2.Remove the cap from any automatic air vent in the system and check operation by depress- ing valve “B” slightly with the tip of a screwdriver.

3.If the air vent valve appears to be working freely and not leaking, replace cap “A”, twisting all the way on.

4.Loosen cap “A” one turn to allow vent to operate.

5.Have vent replaced if it does not operate correctly.

Figure 3 Automatic air vent

Part number 550-142-055/0411

7

Image 7
Contents User’s Information Manual Read/use Please read this page firstHazard definitions STOP!! Read before proceedingAir contamination Combustion air contamination Prevent combustion air contaminationStart-up Perform maintenance per schedule belowCheck boiler area User maintenance proceduresCheck boiler pressure/temperature gauge DailyCheck boiler interior piping MonthlyCheck venting system Check condensate system Test low water cutoff if installedClean vent termination & air intake screens PeriodicOil blower motor Follow boiler shutdown procedureEvery Months END SeasonIntegrated boiler control How it worksGV90+ Water Boiler Operating instructions Operating instructionsSymptom Common Causes Possible Corrections Common problems and solutionsPopping or percolating GV90+ gas-fired water boiler User’s Information Manual GV90+ gas-fired water boiler User’s Information Manual

GV90+ specifications

The Weil-McLain GV90+ is a high-efficiency gas boiler designed to meet the heating demands of residential spaces. Renowned for its reliability and superior performance, the GV90+ is ideal for home heating systems that require both efficiency and comfort.

One of the standout features of the GV90+ is its advanced condensing technology. This allows the boiler to recycle exhaust gases, extracting additional heat and maximizing energy usage. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 90%, the GV90+ significantly reduces energy consumption, lowering heating bills while minimizing environmental impact.

The GV90+ also boasts a versatile design that can be integrated into a variety of heating systems. It is suitable for both hydronic heating applications and combination systems that provide domestic hot water. This adaptability makes it a popular choice for homeowners looking to enhance their existing heating setup or those building new homes.

Built with durability in mind, the GV90+ features a cast aluminum heat exchanger that is not only lightweight but also highly resistant to corrosion. This construction ensures longevity and reduces maintenance needs, thereby providing peace of mind for homeowners. The boiler's compact size further facilitates installation in tight spaces, making it a convenient solution for both new installations and replacements.

The GV90+ is equipped with an intuitive control system that simplifies operation. The integrated electronic ignition removes the need for a standing pilot, enhancing safety and improving reliability. This smart control technology also allows for precise temperature management, ensuring optimal comfort without unnecessary energy consumption.

Another highlight of the GV90+ is its whisper-quiet operation. Designed to minimize noise, this boiler allows homeowners to enjoy a warm and cozy environment without disruptive sounds. Additionally, Weil-McLain has incorporated safety features such as overheat protection and vent safety switches, ensuring the system operates safely within defined parameters.

In conclusion, the Weil-McLain GV90+ sets a high standard in the residential heating market with its exceptional efficiency, innovative technologies, and robust construction. Catering to a range of heating needs, it promises homeowners reliability, comfort, and significant energy savings, making it a wise investment for any home.