EG, PEG, EGH GAS-FIRED BOILERS SERIES 4 — BOILER MANUAL

 

Wiring

Refer to control supplement for additional information

For your safety, turn off electrical power supply before making any electrical connections to avoid possible electrical shock hazard.

All wiring must be installed in accordance with requirements of National Electrical Code and any additional national, state or local code requirements having jurisdiction. ALL wiring must be N.E.C. Class 1. Boiler must be electrically grounded in accordance with National Electrical Code, ANSI/NFPA No. 70-latest edition.

In Canada, installation must conform to CSA C22.1 Canadian Electrical Code Part 1 and any local codes.

If original rollout thermal fuse element wire as supplied with boiler must be replaced, type 200°C wire or equivalent must be used. If other original wiring as supplied with boiler must be replaced, type 105°C wire or equivalent must be used.

Installer must attach wiring diagram inside jacket door.

A separate electrical circuit with a fused disconnect switch (15 amp. recommended) should be used for the boiler.

A strain relief bushing and adapter must be used at each point where wiring passes through control case (see Figure 23) to protect wiring insulation.

Refer to zone valve manufacturer’s literature for wiring and application. A separate transformer is required to power zone valves. Zoning with circulators requires a relay for each circuit.

Install room thermostat

Install room thermostat on an inside wall. Never install where it will be influenced by drafts, hot or cold water pipes, lighting fixtures, television, rays of the sun or near a fireplace.

Refer to Control Supplement or correct wiring diagram for recommended heat anticipator setting with Standard equipment. Wire thermostat as shown.

Figure 23 Wiring multiple zones

Part Number 550-110-639/0703

15

Image 15
Contents EG, PEG, EGH Contents Other size ducting must comply with local codes InstallationCodes Combustion air and ventilation openingsWhen removing boiler from common venting system Chimney or vent requirementsSelect the boiler location Boiler foundation Installation clearancesResidential garage installation Installation of optional indirect water heaterInstallation of flue collector hood Installation of front and back base panelsHydrostatic pressure test Front and back base panels Breeching erection Spill switch installationDamper installation Draft hood installationRefer to tables and Figures 11a and 11b Piping connectionsForced hot water boilers and gravity hot water boilers To protectBypass piping Use with refrigeration systemsMultiple Zoning Condensate receiver capacity Steam boilersLow water cut off for water boilers Install boiler controlsWater boiler Steam boilerOptional heaters For correct operation, install as shown in water boilers orConnecting gas supply piping Gas pipingFor propane gas Install room thermostat WiringFilling water systems Final adjustmentsFreeze protection when used Water treatmentFor propane boilers only Skimming steam boilersInspect base insulation To place in operationEach zone water boilers only? Check-out procedureInstallation and Service Certificate Check-out procedureService Handling fiberglass and ceramic fiber materials Eye Irrigate immediately Breathing Fresh airNiosh stated First Aid End of each heating season Beginning of each heating seasonDaily during heating season Monthly during heating seasonCheck pilot burner flames Clean boiler heating surfacesCleaning main burners Annual shut-down procedureReplacement parts EG Replacement parts EG Replacement parts EGH Replacement parts EGH Data Dimensions EG Dimensions P-EG Dimensions EGHDOE RatingsFor EG steam boilers Standard equipmentEG boilers add For EG water boilers

EG specifications

The Weil-McLain EG Series is a notable line of cast iron, steam, and hot water boilers designed primarily for commercial and residential heating applications. Known for its robustness and efficiency, the EG boiler series has become a preferred choice for many heating professionals.

One of the main features of the Weil-McLain EG series is its durable cast iron construction. This material not only contributes to the longevity of the boiler but also ensures excellent heat retention and uniform heating. The boiler's heat exchanger is optimized to maximize thermal efficiency, delivering reliable and effective heating performance across various applications.

Another key aspect of the EG series is its heating capacity. Available in a range of sizes and outputs, the EG boiler provides flexibility, making it suitable for different heating needs. Whether it’s a small residential installation or a larger commercial system, the EG series offers models that can be tailored to meet specific load requirements.

Advanced technology is integrated into the Weil-McLain EG series to enhance efficiency and ease of use. One notable feature is its ability to operate with both gas and oil fuel types, enabling users to choose the most economical and accessible option for their needs. Additionally, the EG boilers come equipped with a reliable and intuitive control system that simplifies operation and maintenance tasks, allowing users to monitor performance easily.

The EG series also incorporates safety features, such as pressure relief valves and advanced combustion controls, which ensure safe and efficient operation. This attention to safety is essential in protecting both the system and the inhabitants of the building it serves.

Maintenance of the EG boiler is designed to be straightforward, with serviceability being a prominent focus in its design. The boiler's modular components can be accessed easily, significantly reducing downtime for repairs and maintenance.

In conclusion, the Weil-McLain EG series stands out for its reliable performance, efficiency, versatility, and robust construction. Its combination of advanced technology and user-friendly features makes it a leading choice for those seeking a dependable heating solution. Whether for residential or commercial applications, the EG series is engineered to deliver consistent heating while maximizing comfort and minimizing operating costs.