| Thermific® | Installation |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
Whichever termination is chosen, it must be double wall vent certified under UL 1738, or
Correct rain cap, | Typical incorrect |
unrestricted. | rain cap. |
If the exhaust vent is routed through the roof, the termination must be either the same type as described for a sidewall installation or a rain cap. The preferred method to terminate the exhaust vent is with a rain cap to minimize the drippage of condensate onto the roof and ice
Flue Gas
Outlet
unrestrictive type similar to the figure above. Elbows are also acceptable.
3.4.5 Equivalent Length of Fittings
Fitting Description | Equivalent Length |
90º Elbow | 10 feet |
45º Elbow | 5 feet |
Rain Cap | 10 feet |
Boot Tee/135º Tee | 10 feet |
Standard Tee Used as a | 10 feet |
Vent Termination |
|
|
|
3.4CLEARANCES
In addition to any clearance requirements in Sections
3.1and 3.3 the following clearances must be maintained for inlet and vent components.
3.4.1 Sidewall Installations
Flue Gas
Outlet
Combustion
Air Intake
2' to snow line
Page 7