LCD LED

LCD LED

3.Enter the zone number (i.e. 01, 02,...96), or use the [S] and [T] buttons and press [BYP] once the zone you want to bypass appears on the screen. If bypassed, the byp light does not appear on the screen and the keypad emits a rejection beep, you may not have access to bypass that zone.

4.Repeat step 3 until all zones you want to bypass have been selected.

5.Press the [ENTER] button to save and exit.

To view all bypassed zones.

1.Enter your [ACCESS CODE].

2.Press the [BYP] button.

3.Scroll through the zones using the [S] and [T] buttons to view zone status. (LCD Keypads)

In order to bypass a zone, the following conditions must be met:

The zone must have the Bypass option programmed by your installer.

The Bypass option must be enabled in your User Options.

Your user access code must have access to the zone’s Area Assignment.

The zone’s area must be disarmed before the zone can be bypassed.

Fire Zones cannot be bypassed.

5.6.1Bypass Recall

Bypass Recall reinstates the zones that were bypassed the last time your system was armed.

To activate Bypass Recall:

1.Enter your [ACCESS CODE].

2.Press the [BYP] button.

3.Press the [MEM] button.

Zones bypassed the last time your system was armed are bypassed.

4.Press the [ENTER] button to save and exit.

5.6.2One-Touch Buttons

If enabled by your installer, you can access the following features without using your user access code by pressing and holding the desired One-Touch button.

 

Table 1: One Touch Button

Button

Feature

[ARM]

Regular arm

[STAY]

Stay arm

 

 

[FORCE]

Force arm

[BYP]

Bypass Programming

[DISARM]

Disarm a Stay/Instant armed area

 

 

[5]

Instant arm

[6]

Change display settings

[7]

View Event Record display (LCD Keypads only)

 

 

5.7Keyswitch Arming

A key can be used to arm and disarm your system using two forms of keyswitches. With a Maintained Keyswitch, place the key in the “ON” position to arm your system, and place the key in the “OFF” position to disarm your system. With a Momentary Keyswitch, place the key in the “ON” position briefly then place it back in the “OFF” position to arm the system. Repeat this process to disarm with a Momentary Keyswitch.

8 User Guide

Image 10
Contents User Guide Page Table of Contents Introduction User GuideBasic Operation EVO SystemsConfidential Mode Auditory Feedback Beep TonesOther Indicators Full/Force Arming IndicatorsStay/Sleep Arming Indicators MG-REM2 FeedbackPartitioned System Area DisplayArming One-Touch Buttons Keyswitch ArmingBypass Recall One Touch ButtonTimed Auto-Arming Auto-ArmingNo Movement Auto-Arming Disarming Entry Delay TimerAlarm Memory Display Disarming an Armed SystemCopy User Options Access CodesSystem Master Code Default User LabelsKey Press Key Once Keypad ButtonsSpecial Function Keys Stay = Insert Space Deleting User Access Codes Programming User Access CodesProgramming User Settings Access Control User Options User OptionsOptions 4 and 5 Arming with Card Arming and Disarming with Card Using Access ControlEntering & Exiting Arming with CardHow Access Control Works Example aTrouble Display Trouble DisplayEvent Record Display Group 8 Clock LossModifying illumination settings on the DGP2-648BL LED Additional FeaturesKeypad Settings Setting Time & DateProgramming Chime Zones Panic AlarmsQuick Function Buttons VDMP3 Plug-In Voice Dialer Receiving a Call From the VDMP3 alarm in systemCalling the VDMP3 outside line User Guide 12.2 Fire Alarm Testing Testing and MaintenanceBurglar Alarm Testing 12.3 System MaintenanceFire Safety Tips Fire and Burglar AlarmsDelayed Fire Zone Standard Fire ZoneMinimizing Home Fire Hazards Burglar AlarmHome Fire Warning System Appendix 1 Hebrew Special Characters Appendix 2 Russian Special Characters Appendix 3 Greek Special Characters Key Press key once Press key twice Press key three TimesIndex Arming with CardAccess Control, see Access Control User Options Warranty Limitations of Alarm SystemsEVO-EU02