Nilfisk-Advance America SR 5110 P/B, SR 5120 P/B, SR 1200 P/B Use, START/STOP of the Petrol Engine

Page 10

USE

S31NUK5120(3)2001-04

Insert the ignition key into the panel and turn it clockwise: the display will show all zeros and after about three seconds the battery voltage will appear. Note: the temporary lighting of the two side brush indicators and the short sound from the reverse speed acoustic indicator are to be considered a normal behaviour.

Wait not less than three seconds before restarting the machine after switching Off.

Check the charge status of the batteries on the display.

Six different data/functions can be shown on the display.

The six functions are described in the following table.

Displayed datum/function

Display

reading

 

 

 

1. Voltmeter: the battery voltage is normally shown on the

Normally fixed.

display. A block function will be activated in case of battery

(battery voltage)

undervoltage: when battery voltage will be about 20V all

 

machine functions will stop, except traction; in this case the

Flashing when

display will show 0205; proceed then with a battery recharge

0205 appears.

(see Maintenance paragraph)

 

 

 

2. & 3. Hourmeter: to read the machine working time - in

 

hours - press once the yellow display button. By pressing the

Fixed

button a second time the working minutes will appear. Just

waiting ten seconds the display will show the battery voltage

 

again

 

 

 

4. Total swept surface (m2): the displayed value will increase

Fixed

each 1000 m2

 

5. Daily swept surface (m2): the displayed value will increase

Fixed

each 10 m2

 

6. Productivity: sweeping rate m2/hour: it depends on the

Flashing

instantaneous machine working speed

 

 

 

Notes:

- to pass to the next function press the yellow display button once, 10 seconds after choosing one of the possible data/functions

-the display will return automatically to the battery voltage from every function

- data 2 and 3 will increase just using the traction function (accelerator pedal)

- data 4, 5 and 6 will increase only if main broom is turning AND traction function is used

- when datum 5 is displayed you can reset it just by keeping the yellow display button pressed 5 seconds.

- If the batteries are charged enough, now it is possible to start the job (in battery mode).

If the machine is equipped with the gasoline engine, proceed with the start of the engine itself.

START/STOP OF THE PETROL ENGINE

To start the gasoline engine press the red button shown in the figure; to stop the engine press the same button again.

8

Image 10
Contents Sweeper Index S31NUK512032001-04Spare Parts and Maintenance Introduction / General InformationUnpacking Technical Data VersionDescription of Commands Control PanelPreliminary Operations Preliminary Operations Connect the battery connector to the machine USE START/STOP of the Petrol EngineUSE USE of the Working Programs USE USE USE Further Performances Machine with Petrol Engine Side Brushes Adjustment and Replacement Main Brush Replacement Main Brush Replacement Filter Cleaning and Replacement Filter Cleaning and Replacement Maintenance Batteries Control and Recharge Maintenance Brakes Adjustment Front Lamp ReplacementMaintenance of the Petrol Engine Honda Maintenance of the Petrol EngineMaintenance Summary of Maintenance Controls battery versionControls petrol version Optional Items Safety Functions and TROUBLE- Shooting To Push To Drive See Safety CodeService Address AustraliaNilfisk-Advance Italia S.p.A