PRELIMINARY OPERATIONS

S31NUK5120(3)2001-04

2- If the batteries are installed but not filled with acid solution they must be filled with a solution of sulphuric acid (density between 1,270 Kg and 1,290 Kg at 25°C temperature) according to the instructions specified below and in the Battery User Manual.

BATTERY FILLING UP WITH ACID SOLUTION Warning: the battery acid is corrosive; if it comes in contact with the skin or eyes rinse thoroughly with water and consult a physician.

The batteries must be filled in a well ventilated area.

Fill every battery cell with acid; the right level is specified in the Battery User Manual.

After one hour fill up with acid, if necessary.

Let batteries rest for a further hour; then proceed with a recharge according to the instructions specified in the Battery User Manual and in the MAINTENANCE paragraph. During the recharge the battery caps must be open.

WARNING: before starting the recharge the battery connector must be disconnected from the machine.

After the recharge close all the cell caps and clean the top of the battery from any acid remains.

6

Image 8
Contents Sweeper Index S31NUK512032001-04Spare Parts and Maintenance Introduction / General InformationUnpacking Technical Data VersionDescription of Commands Control PanelPreliminary Operations Preliminary Operations Connect the battery connector to the machine USE START/STOP of the Petrol EngineUSE USE of the Working Programs USE USE USE Further Performances Machine with Petrol Engine Side Brushes Adjustment and Replacement Main Brush Replacement Main Brush Replacement Filter Cleaning and Replacement Filter Cleaning and Replacement Maintenance Batteries Control and Recharge Maintenance Brakes Adjustment Front Lamp ReplacementMaintenance of the Petrol Engine Honda Maintenance of the Petrol EngineMaintenance Summary of Maintenance Controls battery versionControls petrol version Optional Items Safety Functions and TROUBLE- Shooting To Push To Drive See Safety CodeService Address AustraliaNilfisk-Advance Italia S.p.A