SAFETY TIPS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
1.Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes ANSI/NFPA
2.including
3.Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the
4.ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
5.such as a tag, to the service panel.
6.Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
7.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7
8.feet from the floor to the trailing edge of the blade.
To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.
9.(Mounting must support at least 35 lbs.)
Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating
10.blades.
11.Attach the mounting bracket using only the hardware supplied with the outlet box.
12.To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
13.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
14.NEVER place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of
15.and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
1 2 3
| Before you begin installing the fan, Switch |
|
|
|
|
|
|
|
|
| Use metal outlet box suitable for fan support | |||||||||
|
|
| Before installing this fan make sure the outlet box is |
|
| (must support 35 lbs). Before attaching fan to | ||||||||||||||
| power off at Service panel and lock service dis- |
|
|
|
| outlet box, ensure the outlet box is securley fas- | ||||||||||||||
| properly installed to the house structure. To reduce | |||||||||||||||||||
| connecting means to prevent power from being |
|
|
|
| tened by at least two points to a structural ceil- | ||||||||||||||
| switched on accidentally. When the service dis- |
|
| the risk of fire, electric shock, or personal injury, |
|
| ||||||||||||||
| connecting means cannot be locked, securely |
|
| mount to outlet box or supporting system acceptable |
|
| ing member ( a loose box will cause the fan to | |||||||||||||
| fasten a prominent warning device, such as a |
|
| for fan support. (Mounting must support at least 35 |
|
| wabble). Use only the screws provided with | |||||||||||||
| tag, to the service panel. |
|
|
|
| lbs.) |
|
|
|
|
| the outlet box. | ||||||||
| 4 |
| Canopy disk |
|
|
| Downrod |
|
|
| 5 |
|
|
|
|
|
| 6 |
|
|
|
|
|
|
|
|
|
|
| Cross Pin |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yoke |
|
|
|
|
|
| Canopy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| Keeper |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Pin |
|
|
|
|
|
| Tread leadwires and |
| safety cable first |
|
|
| Insert downrod into yoke on |
| top of the Fan |
|
| Tighten the 2 Set screws on the Yoke |
| |||||||
|
|
|
|
|
|
|
|
| ||||||||||||
| through the canopy disk, Canopy and |
|
| Body. | Align the hole in the Downrod with the |
|
| once the downrod is in place. |
| |||||||||||
| lastly downrod. |
|
|
|
| hole in the Yoke. Insert the Pin through the |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| Yoke and Downrod until the point appears on |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| the other side. Install the Keeper Pin |
|
|
|
|
|