Monte Carlo Fan Company 5SI owner manual Member of a building and/or may be mounted

Page 2
OUTLET BOX METHOD
TOOLS REQUIRED
Wire Cutters Pliers

SAFETY TIPS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

1. Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1999), including fire-rated construction.

2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

3. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4. Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8. WARNING – Risk of fire, electric shock, or personal injury, The fan in this box may be either directly supported from a structural framing mem- ber of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt

9. Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10. Attach the mounting bracket using only the hardware supplied with the outlet box.

11. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13. NEVER place a switch where it can be reached from a tub or shower.

14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip- ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15. Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Phillips Screwdriver

1 2

 

 

 

 

Warning-Risk of

fire, electric shock, or person-

 

 

 

 

 

 

 

 

 

 

al injury. The fan in this box may be either

 

 

 

 

 

directly supported from a structural framing

 

 

Before you begin installing the fan, Switch power off

 

 

member of a building and/or may be mounted

 

 

 

 

at Service panel and lock service disconnecting means

 

 

to an outlet box marked acceptable for fan sup-

 

 

to prevent power from being switched on accidentally.

 

 

port of of 31.8 kg (70 lbs) or less. Most outlet

 

 

When the service disconnecting means cannot be

 

 

boxes commonly used for the support of lummi-

 

 

locked, securely fasten a prominent warning device,

 

 

naires may not be acceptable for fan support

 

 

such as a tag, to the service panel.

 

 

and may need to be replaced. Consult a quali-

 

 

 

 

 

fied electrician if in doubt.

 

 

 

 

Step Ladder

3 BUILDING STRUCTURE METHOD

Outlet box

Wood Mounting

Screws Bracket

Secure mounting bracket directly to a joist from the buliding structure via the two knock out holes on the outlet box. Use only the appropri- ate wood screws and washers included with your fan. Caution: Wood screws must go through into the building joist.

4

5

6

Install canopy and yoke cover over the down- rod.

Thread wire through downrod with canopy and yoke cover assembled.

Insert downrod into motor yoke. Next, insert clevis pin through yoke and downrod and secure with cotter pin. (see inset)

Image 2
Contents Owner’s Manual Member of a building and/or may be mounted Port of of 31.8 kg 70 lbs or less. Most outletPlace blade onto blade holder BlackBlack Blue White Green For Light Kit Installation Only Not USE a Solid State variable speed control

5SI specifications

The Monte Carlo Fan Company 5SI is a remarkable ceiling fan that seamlessly combines aesthetic appeal with advanced functionality. Renowned for its sleek design, the 5SI offers a modern twist to traditional ceiling fans, making it an ideal choice for contemporary homes and commercial spaces alike.

One of the standout features of the 5SI is its minimalist design, which incorporates clean lines and a discrete profile. This ceiling fan is available in a variety of finishes, including brushed nickel, matte black, and antique brass, allowing it to complement diverse interior decor styles. The fan's 52-inch blade span is perfect for medium to large rooms, delivering excellent airflow while maintaining a stylish appearance.

The Monte Carlo 5SI is equipped with energy-efficient DC motors, which not only contribute to its quiet operation but also enhance its overall performance. These motors consume significantly less energy compared to traditional AC motors, making the 5SI an environmentally friendly choice. The whisper-quiet operation is particularly beneficial for bedrooms, living rooms, or any space where noise is a concern.

Another notable technology featured in the 5SI is its easy-to-use remote control system. The remote allows users to easily adjust the fan speed and light settings without the need for a wall switch. This added convenience enhances user experience, making it simple to create the perfect ambiance in any room.

The fan blades of the 5SI are crafted from high-quality materials, ensuring durability and longevity. The fan is designed with an aerodynamic shape to maximize airflow while minimizing noise. The 5SI’s blades are reversible, offering versatility in airflow direction; this means that users can enjoy a refreshing breeze during the summer months and warm air circulation during winter.

The Monte Carlo 5SI also features integrated LED lighting options, which provide bright and efficient illumination. The LED bulbs are designed to last longer and consume less energy compared to traditional bulbs, making them an ideal choice for energy-conscious consumers. With dimmable capabilities, the lighting can be adjusted to set the mood for any occasion.

In summary, the Monte Carlo Fan Company 5SI stands out as a premium ceiling fan that successfully merges style, efficiency, and advanced technology. Its modern design, energy-efficient motor, user-friendly remote control, durable materials, and integrated LED lighting make it an attractive and practical choice for those looking to enhance their living or working space.