Mitsumi electronic CMY-R200VBK Pipe Connection Example, Insulation Cover Installation

Page 4

(6) The length of the straight pipe between indoor units and the twinning pipe (high-pressure pipe)

Use the pipes supplied in the twinning kit, and make sure the section of the field-supplied pipe that connects to the twinning pipe has at least 500 mm [19-11/16 in] of straight section. (The section of the field-supplied pipe that connects to the twinning pipe must have at least 500 mm [19-11/16 in] of straight section.) If the straight section is less than 500 mm [19-11/16 in],

it may result in equipment damage.

(7) Pipe connection (high-pressure side)

Make sure pipes from the twinning pipe to the outdoor unit are sloped downwards.

100mm [4 in]

A

B

To BC controller

Downward slope

 

or more

 

 

To BC controller

Upward slope

High-pressure twinning pipe

Total pipe length = A + B < 5m [16-7/16 ft]

200mm max.

·If high-pressure twinning pipe is installed above the base of the outdoor unit, it should be no more than 200mm [7-7/8 in].

Outdoor unit 1

Outdoor unit 2

High-pressure twinning pipe

To indoor unit

3. Pipe Connection Example

Connect the pipes between outdoor units, using the figure below as a reference.

1Low-pressure twinning kit

Low-pressure connecting pipe (field-supplied)

High-pressure connecting pipe (field-supplied)

2High-pressure twinning pipe

Main low-pressure pipe (field-supplied)

 

Main high-pressure pipe (field-supplied)

4. Insulation Cover Installation

Install the insulation cover on the twinning kit after brazing the pipes and twinning kit.

Insulate all refrigerant pipes. Insulate the high-pressure and low-pressure pipes separately, and pipes located inside the unit as well as the outside. Use heat-resistant insulation material (Heat resistant : at least 120˚C [248˚F], Thickness: high-pressure = 10 mm [13/32 in], low-pressure = 20 mm [13/16 in] ). Position the edges of the insulation cover and heat-resistant insulation material so as not to leave a gap, and then wrap the exterior perimeter of the pipe joints and middle with tape (field-supplied).

field-supplied pipe

field-supplied pipe

2High-pressure

twinning pipe field-supplied pipe

Heat-resistant insulation material (field-supplied)

Tape (field-supplied)

To be gap free

To be gap free

LInsulation cover

Heat-resistant insulation material (field-supplied)

Insulation cover

Heat-resistant insulation material (field-supplied)

Overlap margin of the tape

Tape (field-supplied)

Insulation covers can shrink. Overlap the tape as shown in the left figure so that there will be no gap in between the insulation cover or field-installed insulation material.

5. Miscellaneous Notes

Secure the field-supplied pipes with a pipe cover and a cable tie in place to keep them from coming in contact with other pipes as necessary.

WT05221X02

See reverse.

4

Image 4
Contents Safety Precautions Confirming the Package Contents Pipe cover with Cable tie Pipe Connection Example Insulation Cover InstallationMiscellaneous Notes

CMY-R100VBK, CMY-R200VBK specifications

The Mitsumi electronic CMY-R100VBK and CMY-R200VBK are cutting-edge components designed to meet the diverse needs of modern electronic devices. These products reflect Mitsumi's commitment to quality and innovation in the realm of electronic manufacturing, ensuring that users receive reliable and high-performance solutions for their applications.

The CMY-R100VBK is a versatile device that excels in its ability to handle a variety of tasks efficiently. It features advanced communication interfaces, including multiple I/O ports for easy integration into various systems. This model is particularly suited for applications in consumer electronics, where a compact and energy-efficient solution is paramount. The CMY-R100VBK also boasts a robust power management system, allowing for seamless operation even in fluctuating power conditions, which is essential for portable and battery-operated devices.

In contrast, the CMY-R200VBK offers enhanced capabilities, making it ideal for more demanding applications. It includes additional computational power and memory, allowing for faster processing times and improved multitasking capabilities. This model is perfect for applications in industrial automation and smart home technologies, where speed and reliability are critical. The CMY-R200VBK's design also incorporates advanced thermal management, ensuring stable performance even under heavy loads.

Both models are equipped with advanced technologies such as built-in diagnostic features, which provide real-time monitoring and troubleshooting capabilities. This functionality helps engineers and technicians quickly identify and resolve issues, reducing downtime and increasing overall efficiency. The ease of use and integration provided by both models makes them a favorite among developers and manufacturers alike.

Furthermore, the CMY-R100VBK and CMY-R200VBK demonstrate versatility in their compatibility with various communication protocols, including I2C and SPI. This allows them to communicate seamlessly with a wide range of peripherals and sensors, enhancing their adaptability for different applications.

In summary, Mitsumi's CMY-R100VBK and CMY-R200VBK represent the pinnacle of modern electronic design, combining compactness, efficiency, and flexibility to cater to the evolving demands of the technology landscape. Whether for consumer applications or industrial systems, these models provide users with the performance and reliability essential for today's high-tech world.