Mermaid Air Conditioner manual Cooling water in and out, Water

Page 6

CONDENSATION WATER CAN COME IN CONTACT WITH IT SHOULD THE

CONDENSATION WATER OVER FLOW ITS PAN. NEVER PLACE THE

ELECTRICAL BOX BELOW THE AIR CONDITIONING UNIT.

WARNING

IF CONDENSATION WATER CONTACTS THE ELECTRICAL BOX

ELECTRICAL SHORTING COULD OCCUR CAUSING FIRE WHICH COULD RESULT IN SERIOUS INJURY, DEATH AND/OR DESTRUCTION OF THE BOAT.

We suggest that once you are satisfied that the unit and electrical box, along with all of the other items required in the air conditioner compartment will fit, that you remove the air conditioning unit and electrical box or cover them completely until all holes and construction in the compartment are completed and the area cleanly vaccuumed.

2. Cooling water in and out:

All central marine air conditioning and heating units are water cooled. Cooling water is provided to the air conditioner via a foot scoop, sea cock, water strainer and pump assembly all of which are mounted below sea level. Typically the sea cock, water strainer and pump are installed remotely to the air conditioner (SEE FIGURE 3).

Water In:

Generally, in power boats, the sea cock will be installed in the engine compartment. In sail boats, because of their more uniform draft characteristics, it is usually installed under a settee seat or some other compartment more convenient to the air conditioner.

Water is then routed to the air conditioner from the pump via 5/8 inch marine water hose (also known as ½” I.D. hose) where it is connected to the air conditioner condensing coil's "water in" connection. Make sure that space is allowed around the unit to make this connection. The water hose is easily kinked, restricting water flow. If needed, use a hose barb 90 degree fitting to eliminate any kinking. (These can be found at any pvc supply store).

An additional length of 5/8 inch marine hose (again, ½” I.D.) is connected to the condensing coil "water out" connection. Cooling water passes through the condensing coil and routed through this hose to the "water out" thru-hull fitting which will be installed above water level in the side of the boat’s hull (SEE FIGURE 3).

IMPORTANT

THE SEA COCK, WATER STRAINER AND WATER PUMP MUST BE

INSTALLED BELOW SEA LEVEL. THE SEA WATER PUMP IS NOT SELF PRIMING AND RELIES ON WATER SEEKING ITS OWN LEVEL ALONG WITH THE HYDRAULIC PRESSURE OF THE BOAT TO ATTAIN PRIMING OF THE PUMP.

Image 6
Contents Mermaid Marine AIR Conditioning Table of Contents Installation and Operation OverviewAIR Conditioner Installation Installing the Air Conditioner Unit AIR Conditioner Dimensions Unit BTU Width Length HeightCooling water in and out WaterPage Page Water Strainer Pump Water Out Electrical Power Air Ducting and Splitting Return Air Return AIR RequirementsModel BTU SQ. Inches of Return High Pressure Switch Access Condensation RemovalPage Putting it all together Making contact with the hullSee Warning below Wire Connections Power System OperationPriming The Pump Checking Out The System Setting the Current DAY and Time IntroductionPage Normal Operation Temperature Override and Temperature HoldTemporary Temperature Override Programming the ThermostatVacation Temperature Hold InstallationPage Maintenance Water SystemAir System Electrical System WinterizationAir Conditioning Unit and Water Pump Theory of Operation and Trouble Shooting Clean AIR ACT Amendments of 1990 Title VI C-1Theory of Operation General Heating Options ElectricalTrouble Shooting Cooling WaterStandard 24v Thermostat In Cool Position No Operation Page Compressor Runs Fan Does Not No Water OutEvaporator Freezing Condensation Pan OverflowsNo Heat Electric Heat Unit Fan Runs High Pressure Switch Activates In Cooling ModeHigh Pressure Switch Activates In Heating Mode No Heat Reverse Cycle Unit Compressor And Fan RunOUR Normal Procedure for a Warranty Issue is AS Follows