Hisense Group KFR 33GWE Schematic Diagram, KFR-33GWE KFR-28GWE KFR-25GWE KFR-2101GWE KFR-3201GWE

Page 21

Schematic Diagram

1. Main specifications of the product

Type

KFR-33GWE

KFR-28GWE

KFR-25GWE

KFR-2101GWE

KFR-3201GWE

 

 

 

 

 

 

Power source

AC,230V/50Hz

AC,230V/50Hz

AC,230V/50Hz

AC,230V/50Hz

AC,230V/50Hz

 

 

 

 

 

 

Power consumption of input

1220W/1260W

1000W/1020W

950W/950W

750W/710W

1250W/1400W

(cooling/heating)

 

 

 

 

 

Power (cooling/heating)

3300W/3550W

2800W/3200W

2500W/3000W

2100W/2300W

3200W/3750W

 

 

 

 

 

 

Air flow (high)

450m3/h

450m3/h

450m3/h

340m3/h

420m3/h

Refrigeration dose/consumption

R22/1.30kg

R22/1.27kg

R22/0.84kg

R22/0.70kg

R22/1.18kg

 

 

 

 

 

 

Maximum remote control range/

8m/80

8m/80

8m/80

8m/80

8m/80

angle range

 

 

 

 

 

Maximum length of the connect tube

15m

15m

15m

15m

15m

 

 

 

 

 

 

2. Refrigerant Flow Diagram

Indoor unit

Outdoor unit

Compressor

Wide tube

Accumulator

Wide service valve

4-way valve

Heat exchanger

 

Heat exchanger

 

Narrow

 

 

service

 

Narrow tube

tube

Capillary

 

 

 

Check valve

Capillary

Cooling cycle

Heating cycle

3. Permitted ambient temperature for the air conditioner is following:-7~+43(GB/T 7725-1996)

19

Image 21
Contents KFR 33GWE KFR 28GWE KFR 25GWE Compact Size Alert Symbols ContentsPage Composition of the Air Conditioner Power lamp Hipower lampTimer lamp ON/OFF buttonSymbols Timer ON/OFF button Transmitter HR. Timer button High Power buttonDisplay ON/OFF buttonTimer OFF button Timer on buttonTimer SET/CANCEL button Mode selector buttonOperation Guide HOW to Install BatteriesOperation with the Remote Control Unit Adjusting the Fan Speed Horizontal Adjusting the Airflow DirectionVertical Sweep functionNight Setback / Simultaneous Use Energy Saving Night Setback ModeUsing the 12-Hour on and OFF Timer Setting ProceduresSetting Procedure High Power Operation Using the 1-Hour OFF TimerCancellation procedure Cancellation proceduresSpecial Remarks Heating Operation Heating performance Defrosting Power lampOperation without the Remote Control Unit Care and CleaningCare and Cleaning Tips for Energy Saving TroubleshootingKFR-33GWE KFR-28GWE KFR-25GWE KFR-2101GWE KFR-3201GWE Schematic DiagramElectric Wiring Diagram Outdoor Packing List