Glowworm Lighting 200 I, 250 I, 300 I manual Wiring diagram

Page 17

2 Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEY

14238

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BROWN

br

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

bl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORANGE

or

 

 

230v~ PCSA

 

R

 

NTCA TAC1 TAC2 GAIN

 

 

 

WHITE

w

 

 

ENL EN L

 

21

 

 

 

 

 

 

 

 

PURPLE

p

 

FUSED

 

 

 

 

 

 

 

 

 

GREEN

gn

 

 

 

 

 

 

 

 

 

 

 

 

 

GREY

g

 

AT 3A

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/YELLOW

g/y

FLUROPRO

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLLER

 

 

 

 

 

 

 

 

 

 

 

ADDITIONAL

 

 

 

 

 

 

 

 

 

 

 

E

N

L

L LINK

TERMINAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOCK

 

 

 

 

 

 

 

 

 

 

 

g/y

 

bl

bl

 

 

 

 

 

 

 

TERMINAL BLOCK

 

 

 

 

 

 

 

E

N

L

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

br

 

 

 

 

 

 

 

COMMON 230V

 

 

 

 

 

 

 

 

 

 

 

 

MAINS TERMINAL BLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double

L

N

E

 

 

 

 

 

 

 

 

 

 

 

 

pole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

isolator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AT 3A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLUROCYL

 

 

 

 

 

 

230V~50Hz

 

 

 

 

 

 

 

 

Wiring diagram

 

MAINS SUPPLY

 

 

 

 

RETURN PIPE

 

 

 

 

 

 

 

 

 

 

 

Diagram 2.10

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

Image 17
Contents Solar Hot Water Cylinder FlurocylCustomer Service Introduction Important Information Statutory Requirements Product Specifications Safety InstructionsSafety instructions Frost protection of the twin coil solar cylinderFlurocyl mixed water flow rates Flurocyl cylinder heat-up times boiler partFlurocyl DHW flow rates at 60C Safety regulations Safety devicesContents Temperature controlDimensions DHW Flurocyl pack contents InstallationBoiler heating circuit piping Locating the cylinderMotorised 2 port valve Domestic hot water pipeworkMains water supply Discharge pipework Cold water inlet controls and pipeworkExamples High level discharge terminationThermostat and sensor wiring Electrical installationThermostat setting Wiring diagram Commissioning Maintenance Checklist Inspection and MaintenanceChecking the charge pressure of the expansion vessel ReheatingMalfunction Cause Remedy Solar cylinder Fault FindingMalfunction Cause Remedy Page Page 0020055006