1 Product Specifications

1.1 Intended use

The Glow-worm Flurocyl 200 l, Flurocyl 250 l and Flurocyl 300 l are unvented, indirectly heated hot water cylinders for use with solar systems and boilers for the provision of domestic hot water.

IMPORTANT: Risk of damage! The appliances may only be used to heat up potable water. Damage to the appliance due to corrosion cannot be excluded if the water does not correspond to the specifications of the water ordinance.

Any other use or extended use is considered to be improper. The manufacturer/supplier is not liable for any resulting damage.

Intended use includes the observance of the instructions and the adherence to the servicing requirements.

1.2 Data badge

The data badge has been applied to the top of the solar cylinder by the manufacturer.

1.3 Safety devices

The Flurocyl solar cylinder has been provided with all safety and control devices suitable for operation as part of an unvented domestic hot water supply system.

Temperature and pressure relief valve (95°C, 7 bar) Pressure limiting valve (3.5 bar) with line strainer Expansion relief valve (one port valve, 6.0 bar)

Thermal cut out set to 90°C, connected to the solar pump in order to isolate this heat source in the event of failure of the solar control.

Thermal cut out of the immersion heater

Thermal cut out set to 90°C, connected to the motorised 2 port valve, in order to isolate the primary heat source in the event of failure of the domestic water thermostat.

1.4 Safety regulations

This product has been checked for adherence to the building regulations for unvented hot water cylinder systems. It may not be changed or modified in any way whatsoever.

It should be installed by a qualified specialist, who should observe the applicable regulations of the local authorities, the building regulations, the building regulations for Scotland, the building regulations for Northern Ireland and the directives of the local water supply companies. Only original spare parts may be used for the replacement of parts.

1.5 Contents

Check the contents of the pack, see diagram 2.1.

Make sure the cylinder is stored in an upright position in a dry environment prior to its installation.

1.6 Transport

A cylinder carrying handle is supplied to make the transport to the installation site easier.

Fasten the carrying handle to the hot water outlet connection of the solar cylinder.

1.7 Solar Cylinder Charicteristics

Flurocyl solar cylinders are available in three sizes: 200, 250 and 300 litres. The containers are made of stainless steel and insulated with EPS.The cylinders are equipped with all necessary cold and hot water control devices and a motorised 2 port valve.

The Flurocyl cylinders are operated at the pressure of the water supply pipe and do not need a cold water tank for their supply. They have hot and cold water connections of 22 mm diameter. A cold water supply of appropriate pressure and flow rate is required to operate the solar cylinder ideally, refer to section 2.6.

Temperature control

The solar water heating control thermostat is part of the solar control with sensor attached to the Flurocyl solar cylinder.

The cylinder includes the boiler and imersion heater control thermostats that are factory fitted and set.

A themostatic mixing valve must be fitted to the outlet of the cylinder and must be adjusted to the desired domestic hot water temperature.

The cylinder also includes the solar, boiler and immersion heater thermal cut outs that are factory fitted and set.

The solar pump must be connected to the solar control via the solar thermal cut out (TCO), It ensures the solar pump is switched off if the hot water temperature in the cylinder rises above 90°C.

Immersion heater

The Flurocyl solar cylinders are equipped with an additional immersion heater of 3 kW, including the control thermostat and thermal cut out. The immersion heater is situated behind the front plate.

NOTE: In the event of a replacement, only the right immersion heater equipped with a thermal cut out fur overheating protection may be used.

CARRYING

14180

HANDLE

 

Carrier handle

Diagram 1.4

 

 

 

 

Image 8
Contents Flurocyl Solar Hot Water CylinderCustomer Service Introduction Important Information Statutory Requirements Safety Instructions Product SpecificationsSafety instructions Frost protection of the twin coil solar cylinderFlurocyl mixed water flow rates Flurocyl cylinder heat-up times boiler partFlurocyl DHW flow rates at 60C Safety devices Safety regulationsContents Temperature controlDimensions DHW Installation Flurocyl pack contentsLocating the cylinder Boiler heating circuit pipingMotorised 2 port valve Domestic hot water pipeworkMains water supply Cold water inlet controls and pipework Discharge pipeworkHigh level discharge termination ExamplesThermostat and sensor wiring Electrical installationThermostat setting Wiring diagram Commissioning Inspection and Maintenance Maintenance ChecklistChecking the charge pressure of the expansion vessel ReheatingFault Finding Malfunction Cause Remedy Solar cylinderMalfunction Cause Remedy Page Page 0020055006