Safety Instructions
Safety instructions
NOTE: In the event of leaks in the water pipework close the main cold water stop valve. This is often located under a kitchen sink.
IMPORTANT: A thermostatic mixing valve must be fitted to the outlet of the cylinder and can be adjusted to the desired domestic hot water temperature by an installation or service engineer. Otherwise there is a risk of scalding as the cylinder outlet temperature at the taps could be up to 85°C.
IMPORTANT: Risk of damage! Do not remove or modify any components of the solar cylinder.
In the unlikely event of a malfunction occurring of the Flurocyl, such as hot water flowing out of the temperature and pressure relief valve, switch off the boiler and the immersion heater and contact
Frost protection of the twin coil solar cylinder
You must drain the solar cylinder completely if it is to be shut down in a room prone to frost. It is drained at the cold water inlet with a
Also drain all heat exchangers which are not filled with solar fluid.
1 Product Specifications
| Unit | Flurocyl 200 l |
| Flurocyl 250 l | Flurocyl 300 l |
Cylinder: |
|
|
|
|
|
Size | l | 200 |
| 250 | 300 |
Maximum water supply pressure | bar |
|
| 10 |
|
Operating pressure | bar |
|
| 3.5 |
|
Pressure limiting valve | bar |
|
| 3.5 |
|
Expansion relief valve | bar |
|
| 6.0 |
|
Hot water expansion vessel admission pressure | bar |
|
| 4.0 |
|
Temperature and pressure relief valve | °C/bar |
|
| 95 / 7.0 |
|
Net weight | kg | 39 |
| 44 | 49 |
Weight (full) | kg | 245 |
| 310 | 340 |
Height | mm | 1499 |
| 1789 | 2109 |
Cylinder connections: |
|
|
|
|
|
Cold water supply |
| 22 mm pressure pipe |
| ||
Hot water connection |
| 22 mm pressure pipe |
| ||
| 22 mm pressure pipe |
| |||
Secondary return | Inches | G 3/4 |
|
| |
Flow (boiler/solar circuit) |
| 22 mm pressure pipe |
| ||
Return (boiler/solar circuit) |
| 22 mm pressure pipe |
| ||
Electrical connections: |
|
|
|
|
|
3 kW immersion heater (according to ENBS 60335) |
| 230/240 V, 50 Hz |
|
| |
Length of the immersion heater | mm | 430 |
|
|
|
Motorised 2 port valve |
| 230/240 V, 50 Hz |
|
| |
Cylinder thermostat |
| 230/240 V, 50 Hz |
|
| |
Thermal cut out for solar pump |
| 230/240 V, 50 Hz |
|
| |
Heating coil: |
|
|
|
|
|
Heat loss | kW/24 h | 1.9 |
| 2.1 | 2.4 |
Heat up time (boiler part) | mins | 21 |
| 26 | 30 |
Recovery (boiler part) | mins | 13 |
| 16 | 21 |
Table 1.1 Technical data