Glowworm Lighting 250 I, 300 I Safety Instructions, Product Specifications, Safety instructions

Page 6

Safety Instructions

Safety instructions

NOTE: In the event of leaks in the water pipework close the main cold water stop valve. This is often located under a kitchen sink.

IMPORTANT: A thermostatic mixing valve must be fitted to the outlet of the cylinder and can be adjusted to the desired domestic hot water temperature by an installation or service engineer. Otherwise there is a risk of scalding as the cylinder outlet temperature at the taps could be up to 85°C.

IMPORTANT: Risk of damage! Do not remove or modify any components of the solar cylinder.

In the unlikely event of a malfunction occurring of the Flurocyl, such as hot water flowing out of the temperature and pressure relief valve, switch off the boiler and the immersion heater and contact Glow-worm or your installer.

Frost protection of the twin coil solar cylinder

You must drain the solar cylinder completely if it is to be shut down in a room prone to frost. It is drained at the cold water inlet with a T-piece with tap to be provided by the installer.

Also drain all heat exchangers which are not filled with solar fluid.

1 Product Specifications

 

Unit

Flurocyl 200 l

 

Flurocyl 250 l

Flurocyl 300 l

Cylinder:

 

 

 

 

 

Size

l

200

 

250

300

Maximum water supply pressure

bar

 

 

10

 

Operating pressure

bar

 

 

3.5

 

Pressure limiting valve

bar

 

 

3.5

 

Expansion relief valve

bar

 

 

6.0

 

Hot water expansion vessel admission pressure

bar

 

 

4.0

 

Temperature and pressure relief valve

°C/bar

 

 

95 / 7.0

 

Net weight

kg

39

 

44

49

Weight (full)

kg

245

 

310

340

Height

mm

1499

 

1789

2109

Cylinder connections:

 

 

 

 

 

Cold water supply

 

22 mm pressure pipe

 

Hot water connection

 

22 mm pressure pipe

 

Pressure-controlled cold water outlet

 

22 mm pressure pipe

 

Secondary return

Inches

G 3/4

 

 

Flow (boiler/solar circuit)

 

22 mm pressure pipe

 

Return (boiler/solar circuit)

 

22 mm pressure pipe

 

Electrical connections:

 

 

 

 

 

3 kW immersion heater (according to ENBS 60335)

 

230/240 V, 50 Hz

 

 

Length of the immersion heater

mm

430

 

 

 

Motorised 2 port valve

 

230/240 V, 50 Hz

 

 

Cylinder thermostat

 

230/240 V, 50 Hz

 

 

Thermal cut out for solar pump

 

230/240 V, 50 Hz

 

 

Heating coil:

 

 

 

 

 

Heat loss

kW/24 h

1.9

 

2.1

2.4

Heat up time (boiler part)

mins

21

 

26

30

Recovery (boiler part)

mins

13

 

16

21

Table 1.1 Technical data

Image 6
Contents Flurocyl Solar Hot Water CylinderCustomer Service Introduction Important Information Statutory Requirements Safety instructions Safety InstructionsProduct Specifications Frost protection of the twin coil solar cylinderFlurocyl cylinder heat-up times boiler part Flurocyl DHW flow rates at 60CFlurocyl mixed water flow rates Contents Safety devicesSafety regulations Temperature controlDimensions DHW Installation Flurocyl pack contentsMotorised 2 port valve Locating the cylinderBoiler heating circuit piping Domestic hot water pipeworkMains water supply Cold water inlet controls and pipework Discharge pipeworkHigh level discharge termination ExamplesElectrical installation Thermostat settingThermostat and sensor wiring Wiring diagram Commissioning Checking the charge pressure of the expansion vessel Inspection and MaintenanceMaintenance Checklist ReheatingFault Finding Malfunction Cause Remedy Solar cylinderMalfunction Cause Remedy Page Page 0020055006