Goldstar M5403R, WM-6011, M6003R Room AIR Conditioner Voltage Limits, Complaint Cause Remedy

Page 23

ROOM AIR CONDITIONER VOLTAGE LIMITS

NAME PLATE RATING

MINIMUM

MAXIMUM

 

 

 

115V ± 10%

103.5V

126.5V

 

 

 

COMPLAINT

CAUSE

REMEDY

 

 

 

 

Fan motor will not run.

No power

Check voltage at outlet. Correct if none.

 

 

 

 

 

Power supply cord

Check voltage to rotary switch. If none, check

 

 

power supply cord. Replace cord if circuit is

 

 

open.

 

 

 

 

 

Rotary switch

Check switch continuity. Refer to wiring diagram

 

 

for terminal identification. Replace switch if

 

 

defective.

 

 

 

 

 

Wire disconnected or

Connect wire. Refer to wiring diagram for

 

connection loose

terminal identification. Repair or replace loose

 

 

terminal.

 

 

 

 

 

Capacitor (Discharge

Test capacitor.

 

capacitor before testing.)

Replace if not within ±10% of manufacturer's

 

 

rating. Replace if shorted, open, or damaged.

 

 

 

 

 

Will not rotate

Fan blade hitting shroud or blower wheel hitting

 

 

scroll. Re-align assembly.

 

 

Units using slinger ring condenser fans must

 

 

have 0.22~0.25 inch clearance to the base.

 

 

If necessary, shim up the bottom of the fan motor

 

 

with mounting screw(s).

 

 

Check fan motor bearings; if motor shaft will not

 

 

rotate, replace the motor.

 

 

 

 

Fan motor runs.

Revolves on overload

Check voltage. See limits on this page.

 

 

If not within limits, call an electrician.

 

 

Test capacitor.

 

 

Check bearings. Does the fan blade rotate

 

 

freely?

 

 

If not, replace fan motor.

 

 

Pay attention to any change from high speed to

 

 

low speed. If the speed does not change,

 

 

replace the motor.

 

 

 

 

— 23—

Image 23
Contents Room AIR Conditioner Preface ContentsModels SpecificationsSafety Precautions Insulation Resistance TestLocations of Controls 1.5.1 Controls COOL/FAN/DRY Remote Controller PowerCabinet Disassembly InstructionsMechanical Parts Front GrilleORIFICE, Turbo FAN and FAN AIR Handling PartsAIR Guide Upper Overload Protector Electrical PartsMotor AIR GuideControl Panel CompressorCapacitor ThermistorEvaporator Power CordRefrigerant Cycle CondenserCapillary Tube Pulling Vacuum Window Requirements InstallationHOW to Install Select the Best LocationAttach L Bracket Before InstallationNOW Start Installation Locating Unit in WindowOutside How to Secure the Drain pipeInstall the Sash Seal and Sash Lock Secure the Guide PanelsUSE of Extension Cords Troubleshooting GuideElectrical Data Condenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Possible Trouble Electric Parts Troubleshooting GuideSet the Temp. setting to higher Temp Is the voltage No.10 Complaint Cause Remedy Room AIR Conditioner Voltage LimitsReplace if open. If the compressor temperature is Complaint Cause Remedy Description QTY Schematic DiagramCircuit Diagram Electronic Control Device For Main P.W.B ASM Components LocationW0CZZ Exploded ViewLocation no Description Service Parts ListLWJ0611PCG Description RemarkFebruary No A20038B

LWC061JGMK1, LWJ0611PCG, M5203L, M5203R, M6003R specifications

The Goldstar M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R are an impressive lineup of home appliances that combine advanced technologies with user-friendly features. Each model showcases unique characteristics that cater to various consumer needs.

The Goldstar M5203R is known for its robust functionality and sleek design. It features energy-efficient capabilities, minimizing electricity consumption while maximizing performance. The spacious interior allows for ample storage, accommodating various household items seamlessly. Its intuitive control panel ensures ease of use, making it accessible for all family members.

The WM-6011 represents innovation in laundry solutions. This model is equipped with multiple washing programs, allowing users to customize settings based on fabric type and load size. One of its standout features is the steam technology, which helps lift tough stains and reduce wrinkles, providing a professional cleaning experience at home. Additionally, the appliance operates with a quiet wash cycle, ideal for households where noise could be disruptive.

The M5203L builds upon its predecessor's idea, offering a larger capacity designed for bigger families or individuals who prefer to wash fewer loads. This model incorporates smart technology, enabling users to monitor wash progress through a mobile app, ensuring convenience for the modern lifestyle. It also features an anti-vibration system that stabilizes the machine during operation, further reducing noise and enhancing durability.

The LWC061JGMK1 is a standout model in the Goldstar range, particularly known for its innovative refrigerating technology. Equipped with a precise temperature control system, this model ensures food items remain fresh for extended periods. It also features energy-saving modes, aligning with environmentally friendly practices while providing optimal cooling performance.

Lastly, the M5403R offers robust cooking capabilities, with advanced heating elements that ensure even cooking. This model includes several preset cooking modes and an automatic timer, simplifying meal preparation. Its sleek design complements any kitchen décor, making it an attractive and practical addition to any home.

In summary, the Goldstar collection, featuring M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R, emphasizes performance, energy efficiency, and user convenience. These appliances cater to various household needs, ensuring that Goldstar remains a trusted name in home technology.