3.INSTALL THE AIR CONDITIONER IN THE WINDOW

a.Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the

L bracket. See Figure. 27.

IMPORTANT :

When the air conditioner drops into the L bracket, the air conditioner will be centered in window opening as shown in Figure. 28.

b. While steadying the air conditioner, carefully bring the window sash down behind the upper guide of the air conditioner, as shown in Figure. 29.

4. SECURE THE GUIDE PANELS

Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Figure. 30.

INNER SILL

OUTER SILL

TYPE A INSIDE

 

CENTER LINE

 

8"

SHORT SIDE

8"

OUTSIDE

Figure 27

LBRACKET

Figure 28

CENTER LINE

 

WINDOW FRAME

UPPER GUIDE SEAL

ABOUT 1/4"

BOTTOM

GUIDE

Figure 29

L BRACKET

5. INSTALL THE SASH SEAL AND SASH LOCK

a. Cut the sash seal (TYPE E) to the window width. Stuff

the sash seal between the glass and the window to

prevent air and insects from getting into the room, as

shown in Figure. 30.

b. Fasten the L bracket using a (TYPE A) screw, as

shown in Figure. 30.

6. Window installation of room air conditioner is now

LBRACKET

TYPE A

TYPE B

SASH SEAL

(TYPE E)

completed. See ELECTRICAL DATA for attaching

power cord to electrical outlet.

3.2.4 How to Secure the Drain pipe

In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. (Figure. 31)

Figure 30

hang push

Figure 31

DRAIN CAP

 

 

DRAIN PIPE

— 15—

Image 15
Contents Room AIR Conditioner Preface ContentsModels SpecificationsSafety Precautions Insulation Resistance TestLocations of Controls 1.5.1 Controls COOL/FAN/DRY Remote Controller PowerCabinet Disassembly InstructionsMechanical Parts Front GrilleAIR Handling Parts AIR Guide UpperORIFICE, Turbo FAN and FAN Overload Protector Electrical PartsMotor AIR GuideControl Panel CompressorCapacitor ThermistorEvaporator Power CordRefrigerant Cycle CondenserCapillary Tube Pulling Vacuum Window Requirements InstallationHOW to Install Select the Best LocationAttach L Bracket Before InstallationNOW Start Installation Locating Unit in WindowOutside How to Secure the Drain pipeInstall the Sash Seal and Sash Lock Secure the Guide PanelsTroubleshooting Guide Electrical DataUSE of Extension Cords Condenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Possible Trouble Electric Parts Troubleshooting GuideSet the Temp. setting to higher Temp Is the voltage No.10 Complaint Cause Remedy Room AIR Conditioner Voltage LimitsReplace if open. If the compressor temperature is Complaint Cause Remedy Schematic Diagram Circuit DiagramDescription QTY Electronic Control Device For Main P.W.B ASM Components LocationW0CZZ Exploded ViewLocation no Description Service Parts ListLWJ0611PCG Description RemarkFebruary No A20038B

LWC061JGMK1, LWJ0611PCG, M5203L, M5203R, M6003R specifications

The Goldstar M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R are an impressive lineup of home appliances that combine advanced technologies with user-friendly features. Each model showcases unique characteristics that cater to various consumer needs.

The Goldstar M5203R is known for its robust functionality and sleek design. It features energy-efficient capabilities, minimizing electricity consumption while maximizing performance. The spacious interior allows for ample storage, accommodating various household items seamlessly. Its intuitive control panel ensures ease of use, making it accessible for all family members.

The WM-6011 represents innovation in laundry solutions. This model is equipped with multiple washing programs, allowing users to customize settings based on fabric type and load size. One of its standout features is the steam technology, which helps lift tough stains and reduce wrinkles, providing a professional cleaning experience at home. Additionally, the appliance operates with a quiet wash cycle, ideal for households where noise could be disruptive.

The M5203L builds upon its predecessor's idea, offering a larger capacity designed for bigger families or individuals who prefer to wash fewer loads. This model incorporates smart technology, enabling users to monitor wash progress through a mobile app, ensuring convenience for the modern lifestyle. It also features an anti-vibration system that stabilizes the machine during operation, further reducing noise and enhancing durability.

The LWC061JGMK1 is a standout model in the Goldstar range, particularly known for its innovative refrigerating technology. Equipped with a precise temperature control system, this model ensures food items remain fresh for extended periods. It also features energy-saving modes, aligning with environmentally friendly practices while providing optimal cooling performance.

Lastly, the M5403R offers robust cooking capabilities, with advanced heating elements that ensure even cooking. This model includes several preset cooking modes and an automatic timer, simplifying meal preparation. Its sleek design complements any kitchen décor, making it an attractive and practical addition to any home.

In summary, the Goldstar collection, featuring M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R, emphasizes performance, energy efficiency, and user convenience. These appliances cater to various household needs, ensuring that Goldstar remains a trusted name in home technology.