Goldstar M5203L, WM-6011, M6003R, M5403R, M5203R Replace if open. If the compressor temperature is

Page 24

COMPLAINT

CAUSE

REMEDY

 

 

 

Fan motor noise.

Fan

If cracked, out of balance, or partially missing,

 

 

replace it.

 

 

 

 

Blower

If cracked, out of balance, or partially missing,

 

 

replace it.

 

 

 

 

Loose set screw

Tighten it.

 

 

 

 

Worn bearings

If knocking sounds continue when running or

 

 

loose, replace the motor. If the motor hums or

 

 

noise appears to be internal while running,

 

 

replace motor.

 

 

 

Compressor will not run,

Voltage

Check voltage. See the limits on the preceding

fan motor runs.

 

page. If not within limits, call an electrician.

 

 

 

 

Wiring

Check the wire connections; if loose, repair or

 

 

replace the terminal. If the wires are discon-

 

 

nected, refer to wiring diagram for identification,

 

 

and replace the wires. Check the wire connections;

 

 

If not according to the wiring diagram, correct

 

 

the connections.

 

 

 

 

Thermistor

Check the TEMP control. If not at the lowest

 

 

number, set TEMP control to this setting and

 

 

restart the unit.

 

 

 

 

 

Check the continuity of the thermistor. Replace

 

 

the thermistor if the circuit is open.

 

 

 

 

Capacitor (discharge

Check the capacitor.

 

capacitor before

Replace if not within ±10% of manufacturer’s

 

servicing.)

rating, replace if shorted, open, or damaged.

 

 

 

 

Compressor

Check the compressor for open circuit or

 

 

ground. If open or grounded, replace the

 

 

compressor.

 

 

 

 

Overload

Check the compressor overload if externally mounted.

 

 

Replace if open. (If the compressor temperature is

 

 

high, remove the overload, cool, and retest.)

 

 

 

Compressor cycles on

Voltage

Check the voltage. See the limits on the

overload.

 

preceding page. If voltage is not within these limits,

 

 

call an electrician.

 

 

 

 

Overload

Check overload, if externally mounted.

 

 

Replace if open. (If the compressor temperature

 

 

is high, remove the overload, cool, and retest.)

 

 

 

— 24—

Image 24
Contents Room AIR Conditioner Contents PrefaceSpecifications Safety PrecautionsInsulation Resistance Test ModelsLocations of Controls 1.5.1 Controls Remote Controller Power COOL/FAN/DRYDisassembly Instructions Mechanical PartsFront Grille CabinetAIR Handling Parts AIR Guide UpperORIFICE, Turbo FAN and FAN Electrical Parts MotorAIR Guide Overload ProtectorCompressor CapacitorThermistor Control PanelPower Cord Refrigerant CycleCondenser EvaporatorCapillary Tube Pulling Vacuum Installation HOW to InstallSelect the Best Location Window RequirementsBefore Installation NOW Start InstallationLocating Unit in Window Attach L BracketHow to Secure the Drain pipe Install the Sash Seal and Sash LockSecure the Guide Panels OutsideTroubleshooting Guide Electrical DataUSE of Extension Cords Piping System Condenser CoilsTroubleshooting Guide Unit is running but cooling is ineffectiveFails to Start Electric Parts Troubleshooting Guide Possible TroubleSet the Temp. setting to higher Temp Is the voltage No.10 Room AIR Conditioner Voltage Limits Complaint Cause RemedyReplace if open. If the compressor temperature is Complaint Cause Remedy Schematic Diagram Circuit DiagramDescription QTY Electronic Control Device Components Location For Main P.W.B ASMExploded View W0CZZService Parts List Location no DescriptionDescription Remark LWJ0611PCGFebruary No A20038B

LWC061JGMK1, LWJ0611PCG, M5203L, M5203R, M6003R specifications

The Goldstar M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R are an impressive lineup of home appliances that combine advanced technologies with user-friendly features. Each model showcases unique characteristics that cater to various consumer needs.

The Goldstar M5203R is known for its robust functionality and sleek design. It features energy-efficient capabilities, minimizing electricity consumption while maximizing performance. The spacious interior allows for ample storage, accommodating various household items seamlessly. Its intuitive control panel ensures ease of use, making it accessible for all family members.

The WM-6011 represents innovation in laundry solutions. This model is equipped with multiple washing programs, allowing users to customize settings based on fabric type and load size. One of its standout features is the steam technology, which helps lift tough stains and reduce wrinkles, providing a professional cleaning experience at home. Additionally, the appliance operates with a quiet wash cycle, ideal for households where noise could be disruptive.

The M5203L builds upon its predecessor's idea, offering a larger capacity designed for bigger families or individuals who prefer to wash fewer loads. This model incorporates smart technology, enabling users to monitor wash progress through a mobile app, ensuring convenience for the modern lifestyle. It also features an anti-vibration system that stabilizes the machine during operation, further reducing noise and enhancing durability.

The LWC061JGMK1 is a standout model in the Goldstar range, particularly known for its innovative refrigerating technology. Equipped with a precise temperature control system, this model ensures food items remain fresh for extended periods. It also features energy-saving modes, aligning with environmentally friendly practices while providing optimal cooling performance.

Lastly, the M5403R offers robust cooking capabilities, with advanced heating elements that ensure even cooking. This model includes several preset cooking modes and an automatic timer, simplifying meal preparation. Its sleek design complements any kitchen décor, making it an attractive and practical addition to any home.

In summary, the Goldstar collection, featuring M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R, emphasizes performance, energy efficiency, and user convenience. These appliances cater to various household needs, ensuring that Goldstar remains a trusted name in home technology.