Goldstar M5203L, WM-6011, M6003R, M5403R Refrigerant Cycle, Power Cord, Condenser, Evaporator

Page 10

2.3.6 POWER CORD

1.Disconnect the unit from source of power.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove 2 screws that secure control board to base pan and orifice.

5.Pulls the control board toward you.

6.Remove the grounding screw.

7.Remove a screw securing the clip with cord to the control board.

8.Pull the power cord.

9.Re-install by referring to procedures above.

2.4 REFRIGERANT CYCLE

2.4.1 CONDENSER

1.Remove the cabinet. (Refer to Section 2.1.2)

2.Discharge the refrigerant by using a refrigerant recovery system.

3.Remove the air guide. (Refer to Section 2.2.1)

4.Remove 2 screws which fasten the condenser.

5.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

6.Remove the condenser.

7.Re-install by referring to the procedures above.

2.4.2 EVAPORATOR

1.Remove the cabinet.

2.Discharge the refrigerant by using a refrigerant recovery system.

3.Remove the air guide upper. (Refer to Section 2.2.1)

4.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

5.Remove the evaporator.

6.Re-install by referring to the procedures above.

Figure 18

Figure19

— 10—

Image 10
Contents Room AIR Conditioner Contents PrefaceInsulation Resistance Test SpecificationsSafety Precautions ModelsLocations of Controls 1.5.1 Controls Remote Controller Power COOL/FAN/DRYFront Grille Disassembly InstructionsMechanical Parts CabinetAIR Guide Upper AIR Handling PartsORIFICE, Turbo FAN and FAN AIR Guide Electrical PartsMotor Overload ProtectorThermistor CompressorCapacitor Control PanelCondenser Power CordRefrigerant Cycle EvaporatorCapillary Tube Pulling Vacuum Select the Best Location InstallationHOW to Install Window RequirementsLocating Unit in Window Before InstallationNOW Start Installation Attach L BracketSecure the Guide Panels How to Secure the Drain pipeInstall the Sash Seal and Sash Lock OutsideElectrical Data Troubleshooting GuideUSE of Extension Cords Piping System Condenser CoilsTroubleshooting Guide Unit is running but cooling is ineffectiveFails to Start Electric Parts Troubleshooting Guide Possible TroubleSet the Temp. setting to higher Temp Is the voltage No.10 Room AIR Conditioner Voltage Limits Complaint Cause RemedyReplace if open. If the compressor temperature is Complaint Cause Remedy Circuit Diagram Schematic DiagramDescription QTY Electronic Control Device Components Location For Main P.W.B ASMExploded View W0CZZService Parts List Location no DescriptionDescription Remark LWJ0611PCGFebruary No A20038B

LWC061JGMK1, LWJ0611PCG, M5203L, M5203R, M6003R specifications

The Goldstar M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R are an impressive lineup of home appliances that combine advanced technologies with user-friendly features. Each model showcases unique characteristics that cater to various consumer needs.

The Goldstar M5203R is known for its robust functionality and sleek design. It features energy-efficient capabilities, minimizing electricity consumption while maximizing performance. The spacious interior allows for ample storage, accommodating various household items seamlessly. Its intuitive control panel ensures ease of use, making it accessible for all family members.

The WM-6011 represents innovation in laundry solutions. This model is equipped with multiple washing programs, allowing users to customize settings based on fabric type and load size. One of its standout features is the steam technology, which helps lift tough stains and reduce wrinkles, providing a professional cleaning experience at home. Additionally, the appliance operates with a quiet wash cycle, ideal for households where noise could be disruptive.

The M5203L builds upon its predecessor's idea, offering a larger capacity designed for bigger families or individuals who prefer to wash fewer loads. This model incorporates smart technology, enabling users to monitor wash progress through a mobile app, ensuring convenience for the modern lifestyle. It also features an anti-vibration system that stabilizes the machine during operation, further reducing noise and enhancing durability.

The LWC061JGMK1 is a standout model in the Goldstar range, particularly known for its innovative refrigerating technology. Equipped with a precise temperature control system, this model ensures food items remain fresh for extended periods. It also features energy-saving modes, aligning with environmentally friendly practices while providing optimal cooling performance.

Lastly, the M5403R offers robust cooking capabilities, with advanced heating elements that ensure even cooking. This model includes several preset cooking modes and an automatic timer, simplifying meal preparation. Its sleek design complements any kitchen décor, making it an attractive and practical addition to any home.

In summary, the Goldstar collection, featuring M5203R, WM-6011, M5203L, LWC061JGMK1, and M5403R, emphasizes performance, energy efficiency, and user convenience. These appliances cater to various household needs, ensuring that Goldstar remains a trusted name in home technology.