Danby DPAC120061 owner manual Electrical Specifications, Power Supply Cord

Page 4

Electrical Specifications

1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2.Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit.

3.This appliance draws 11 nameplate amps under Cooling Mode and may be used in any properly wired, general purpose 15 amp household grounded receptacle.

4.For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician. DO NOT USE PLUG ADAPTERS

OR EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord with this unit, use an approved “air conditioner” extension cord only. (available at most local hardware stores)

5.The manufacturers nameplate is located on the

rear panel of the unit and contains electrical and other technical data specific to this unit.

6.To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing.

Important Safety Instructions

The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire. Please refer to the section ‘Power Supply Cord’ for details. In the event the power supply cord is damaged, it cannot be repaired and must be replaced with a new cord from the product manufacturer.

Under no circumstances should this device be be used to turn the unit on or off.

The ‘RESET’ button must always be pushed in (engaged) for correct operation.

The power supply cord must be replaced if it fails to reset when the ‘TEST’ button is pushed in.

Power Supply Cord

The power cord supplied with this air conditioner contains a device that senses damage to the power cord. To test if your power cord is working properly, you must do the following;

1Connect the power supply cord to an electrical outlet.

2.The power supply cord has two buttons located on the head of the plug. One button is marked ‘TEST’, the other button is marked ‘RESET’.

Press the ‘TEST’ button, you will then hear a click as the ‘RESET’ button pops out.

3.Press the ‘RESET’ button, you will hear a click as the button engages.

4.The power supply cord is now energized and supplying electricity to the air conditioner. (On some products this is also indicated by a light on the plug head).

Table 1

Suggested Individual Branch Circuit

Nameplate Amps

AWG Wire Size*

11

14

AWG- American Wire Gage

* Based on copper wire at 60°C temperature rating.

 

Table 2

 

 

 

Receptacle and Fuse Types

 

 

 

 

Rated Volts

125

 

Amps

15

 

 

 

 

 

Wall Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse Size

15

 

 

 

 

 

Time Delay Fuse

 

Plug Type

(or circuit breaker)

 

 

 

 

 

 

 

CAUTION

Do not leave this unit unattended in a space where people or animals who cannot react to a failed unit are located. A failed unit can cause extreme overheating or death in such an enclosed, unattended space.

3

Image 4
Contents Manuel ’UTILISATION Table Of Contents Unit Parts IdentificationPower Consumption Unit Specifications DPAC120061Introduction Power Supply Cord Electrical SpecificationsSuggested Individual Branch Circuit Energy-Saving Tips InstallationElectric Shock Hazard Internal Safety Feature To return to normal operationRain Hood Assembly Lock tabs into the 2 slots on the top of eachIndicator Lights & Display Icons Key Pad FunctionsSetting Time of DAY Clock Operating Instructions Air ConditioningU T I O N During air Air Conditioner Operating Instructions cont’dCompressor will not cycle off during continuous mode DRY Dehumidifier Operating InstructionsPage Fan Operating Instructions Low-Med-HighSetting the AUTO-ON Timer Auto-Timer InstructionsFan Setting the AUTO-ON Timer cont’d Setting the AUTO-OFF TimerSetting the AUTO-ON & AUTO-OFF timer During the same programRemote Control Features Battery replacementControl Buttons Batteries should be replaced whenRemote Control Operating Instructions Fan Speed Setting PressCheck the following Cool Low-Medium-High Dry FanRemote Control Operating Instructions cont’d Rnal Water Tank Feature WorksCare and Maintenance Removal and Cleaning of the Air FiltersLimited Product Warranty Table des matières Identification des pièces de l’appareilSpécifications de l’unité DPAC120061 Consommation d’énergieSpécifications électriques Cordon d’alimentationTableau Circuit de distribution individuel suggéréSuggestions pour l’économie de l’énergie Installation dans la fenêtreRisque de choc électrique Caractéristique de sécurité interne Pour retourner aux opérations normalesBrancher l’unité dans une prise de courant Assemblage du ImperméableDe 115 volts / 60 Hz avec mise à la terre Fonctions du bloc de touches Mode Icônes VentilateurAfficheurs et Icônes Directives d’utilisation du climatiseur Directives d’utilisation du climatiseur suite Directives D’UTILISATION DU Déshumidificateur Drain inférieur Vidage Directe 32F Réglage de la Minuterie EN Marche Auto RéglagedelaMINUTERIEENMARCHEAUTOsuite Réglage de la Minuterie Arrêt AutoArrêt AUTO. Appuyer sur la touche Minuterie Caractéristiques de télécommande Remplacement des pilesBoutons de contrôle Les piles devraient être remplacées quandBasse Moyenne Haute Vérifiez ce qui suitFrais Ventilateur Sec Différent Réglage de la températureSoins et entretien Retrait et nettoyage des filtres à airGarantie Limitée Danby y DANBYnb1-800-263-2629Danby Portable 3 Season Home Comfort

DPAC120061 specifications

The Danby DPAC120061 is a portable air conditioner that combines convenience and efficiency, making it an ideal solution for cooling individual rooms or small spaces. This versatile unit boasts a cooling capacity of 12,000 BTUs, which is sufficient for areas up to 450 square feet, ensuring that you stay comfortable even during the hottest months of the year.

One of the standout features of the Danby DPAC120061 is its portability. Equipped with caster wheels and ergonomic handles, this air conditioner can be easily moved from room to room. The included window installation kit further enhances its convenience, allowing users to set it up quickly in various areas of the home without the need for professional installation.

The DPAC120061 is designed with a user-friendly interface, featuring an easy-to-read LED display and remote control that allows users to adjust settings from a distance. It offers multiple cooling and fan speeds, as well as a dehumidification mode that can remove up to 71 pints of moisture from the air per day, helping to improve indoor air quality and comfort.

In terms of energy efficiency, the Danby DPAC120061 is equipped with an eco-friendly refrigerant, R32, which has a lower environmental impact compared to traditional refrigerants. It is Energy Star certified, meaning it meets strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This not only helps reduce energy bills but also makes it a more environmentally responsible choice for consumers.

The built-in programmable timer allows users to set the unit to turn on or off at specific times, further enhancing its energy-saving capabilities. Users can also utilize the quiet mode for nighttime operation, ensuring a restful sleep without disruptive noise.

In summary, the Danby DPAC120061 portable air conditioner is an excellent choice for anyone looking for an effective cooling solution. With its robust performance, portability, user-friendly controls, and energy-efficient design, it meets the needs of modern consumers who value comfort and convenience in their indoor environments. Whether for a living room, bedroom, or office, this unit is adept at maintaining a pleasant atmosphere all summer long.