or deformation with filler or silicone (fig. 4).

Set the supply mains with 1.5 sqmm section (AC 230V - 50 Hz) close to the roof opening .

Drill a hole on the diffuser surface close to the supply cables (fig. 5).

Lay the diffuser on the opening centre, paying attention that the adjusting grate position corresponds to the running direction (check as well the diffuser correct position from the vehicle interior).

Apply some silicone around the diffuser and between diffuser and roof (fig. 6).

Secure the diffuser to the roof by means of the screws provided, then drill some ø 5 mm holes close to the pre- arranged seats and apply silicone to the diffuser external edge.

Fit the self-tapping screw metal stiffeners into their relevant seats.

Lay the supplied seal around the diffuser edge, paying attention that the seal joint is opposite to the running direction (fig. 7).

Connect the wires to the switch by means of the “faston” provided, and the ground wire by means of a terminal (fig. 8).

CAUTION

Always make sure that cables are not power supplied before connecting them.

Set the closed air conditioner on the roof. Open the upper cover and connect the lower part to the previously mounted diffuser (fig. 9), always taking into account the running direction.

Connect the diffuser to the air conditioner using the connectors provided (fig. 10).

Secure the air conditioner to the diffuser by the six supplied screws (fig. 11).

CAUTION

Secure the base to the vehicle roof using the six screws shown in fig. 11. The remaining holes must be free to allow the condensation water to drain out.

Carefully fix the cover (fig. 12)

Make sure that the fan rotates troubleless (fig. 13).

Then fix the frame within the vehicle by using the predrilled holes as reference point (fig. 14).

FORLI' Italy

3.0 INSTRUCTIONS AND RUNNING

IMPORTANT

The firm does not take any responsability for damages arising from malfunctionings of the air conditioner.

3.1AIR CONDITIONER DESCRIPTION AND RUNNING

The air conditioner consists of an A.C.-power supplied compressor, which sets the liquid under pressure in a suitable battery (coil) and heats it. Subsequently the liquid is conveyed to a second low pressure “battery” where it expands, absorbs heat and refrigerates the air coming from the radiator.

Air is conveyed to the vehicle through the special fan at adjustable speed.

Temperature can be adjusted by the suitable thermostat.

Latter can supply fresh and dehumified air in summer and warm air in winter (if fitted).

3.2MACHINE SAFETY

For a safe utilization of the air conditioner, some checks shall be carried out before switching it on:

Check that the water trap holes are not clogged.

Check that voltage and frequence given in the identification plate comply with the values required by the local regulations/provisions.

Check that neither the air inlet nor the air outlet and circulation inside the ducts and the air inlets are hindered.

DANGER

Keep flammable substances like petrol, paints, solvents, etc. away from the air conditioner.

Do not touch the air conditioner or its connections with wet hands.

Any check of the electric parts shall be made with engine stopped and by authorized technicians only.

The air conditioner is manufactured according to the safety rules given in the Conformity Declaration.

3

Image 3
Contents Index Manufacturer Overall DimensionsInstallation IdentificationMachine Safety Instructions and RunningAIR Conditioner Description and Running AIR Conditioner Stopping HOW to USE the AIR ConditionerInternal Temperature Adjustment TroubleshootingEmergency Situations Dealing with Fire Hazards Maintenance InstructionsMaintenance Operations Inactivity and Dismantling1000 1300 Technical Data Technical Specifications Airco BlizzardForli Italy AN Electrolux Company 1000 Forli Forli Italy