TROUBLE SHOOTING continued...
PROBLEM |
| CAUSES |
| SOLUTIONS |
|
|
|
|
|
? Fire goes out or stove shuts down | • | Hopper is empty. | • | Refill hopper. |
automatically. | • Fuel is not feeding. |
| See “Pellets will not feed” below | |
|
| |||
| • | High limit temperature switch has | • | Allow stove to cool for 1 hour and |
|
| tripped. |
| relight. If the stove has been oper- |
|
|
|
| ating at a medium to high burn and |
|
|
|
| the convection fan has been turned |
|
|
|
| down low, then the fan should be |
|
|
|
| turned up higher. If this problem |
|
|
|
| persists, particularly at lower burn |
|
|
|
| rates, then the high limit snap switch |
|
|
|
| should be replaced by your local |
|
|
|
| dealer. |
| • Combustion air too high. | • | Adjust the damper to reduce com- | |
|
|
|
| bustion airflow. |
| • | Fuel feed rate is too low. | • Have an USSC reseller qualified | |
|
|
|
| technician adjust the fuel control. |
|
|
|
|
|
? Pellets will not feed. | • | Hopper is empty. | • | Check contents of the hopper. Add |
| • Auger, circuit board, pressure switch |
| fuel if necessary. | |
|
|
| ||
|
| or relay | • | Have your USSC reseller diagnose |
|
|
|
| the problem and replace the part(s). |
|
|
|
|
|
? Stove runs for 30 minutes and then | • | Exhaust gas is not up to tempera- | • | Relight the stove |
shuts down. |
| ture. |
|
|
| • Low limit snap switch not operating | • Have your USSC reseller replace the | ||
|
| properly; may be defective. |
| low limit switch. |
| • | Wires to the low limit snap switch | • | Contact your USSC reseller for ser- |
|
| (mounted on the side of the firebox) |
| vice. |
|
| are either loose or disconnected. |
|
|
|
|
|
| |
? Blower will not shut off after the fuel | • | Low limit snap switch has failed in | • Have your USSC reseller replace the | |
has been switched off and the stove |
| the closed position. |
| low limit switch. |
has cooled down. |
|
| • It can take up to 1 hour for the unit | |
|
|
| ||
|
|
|
| to cool down enough for the blower |
|
|
|
| to shut off. If it takes longer than 2 |
|
|
|
| hours for the blower to shut off or if |
|
|
|
| it fails to shut off completely contact |
|
|
|
| your local USSC service technician. |
|
|
|
|
|
USSC | 23 |